CS Paper Radar

Does Neural Complexity Improve Health Misinformation Detection? A Leakage-Controlled Cross-Corpus Benchmark

Mkululi SIKOSANA

cs.CL cs.LG ·submitted 2026-10-03 16:26 UTC · v1
benchmarkcode/data

Abstract

Increasing architectural complexity is often assumed to improve health misinformation detection, yet reported gains are difficult to interpret when studies use different corpora, preprocessing pipelines, data splits, and leakage controls. This study provides a controlled cross-corpus benchmark of five compact neural architectures (1D-CNN, LSTM, BiLSTM, CNN-LSTM, and CNN-BiLSTM), a soft-voting neural ensemble, and three classical machine-learning baselines using COVID19-FNIR and CONSTRAINT. Exact-text duplicate controls were applied before modelling; all neural systems used a common preprocessing and optimisation protocol, and neural results were repeated across three random seeds. On COVID19-FNIR, the deep ensemble achieved a mean macro-F1 of 0.9963 and ROC-AUC of 0.9994, while individual neural models ranged from 0.9945 to 0.9957 macro-F1. On CONSTRAINT, the ensemble achieved macro-F1 of 0.9272 and ROC-AUC of 0.9811, whereas a linear SVM achieved macro-F1 of 0.9574 and ROC-AUC of 0.9931. Architecture rankings changed across corpora, and simple sparse linear models remained highly competitive. The findings show that model complexity does not provide a stable performance advantage and that benchmark construction can dominate architecture choice. The study contributes a reproducible, leakage-controlled basis for evidence-driven model selection in health misinformation classification

Comment
18 pages, 3 tables. Reproducibility materials and source code are available from the author

Closest papers

Nearest neighbours by meaning across the whole index.

Auditing evaluation artifacts and data leakage in large language model systems for rare disease diagnosis

cs.AI ·2026-10-24 ·Jian Yang, Peilin Liu, Xiaohan Li, Songda Li, Yu Cao +2 more
benchmark similarity 0.66
Abstract · 18 page, 3 figures

Augmented large language model (LLM) systems have reported high benchmark accuracies in rare disease diagnosis, yet their real-world clinical utility remains unproven. A recent meta-analysis flagged augmented LLM diagnostic evaluations as having a high risk of bias due to suspected data leakage; however, the precise impact of these vulnerabilities on model inference has yet to be fully quantified. In this study, we present a comprehensive empirical audit to quantify evaluation artifacts across prevailing AI paradigms, using a repository of over 60,000 cases from diverse public and independent clinical cohorts. By reconstructing a state-of-the-art agentic framework, we demonstrate that candidate-space contamination artificially inflates performance: enforcing strict cross-dataset isolation resulted in a marked performance decline, with the cross-dataset mean Recall@1 decreasing from 54.3% (under conventional one-vs-rest evaluation) to 40.3% (Hedges' g = 0.94). Similar spatial overfitting in supervised classifiers caused diagnostic accuracy to drop from an internal mean of 42.9% to 16.7% across external cohorts (Cohen's d = 2.01). Furthermore, we quantify how LLMs infer diagnoses by exploiting retrospective therapeutic cues in clinical narratives, and how temporal misalignment in foundational knowledge bases leads to performance fluctuations. We conclude that prevailing evaluation protocols for augmented LLM systems inadvertently reflect data leakage rather than genuine medical reasoning. To address these systematic artifacts, we propose a rigorous evaluation framework - coupling strict data-isolation protocols with standardized benchmarking safeguards - to ensure future diagnostic AI for rare diseases is evaluated on actual clinical robustness.

0.50

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.65
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.44

Hidden Data Challenges in Clinical Machine Learning

cs.LG ·2026-10-09 ·Carolin Cissée, Dennis Fast, Raneen Younis, Alexander Löser, Wolfgang Nejdl +1 more
code/data similarity 0.62
Abstract

Widely reused preprocessing pipelines for electronic health records can encode assumptions about when information became available, what clinical episode a label represents, and what missingness means. These assumptions are rarely audited systematically and may propagate across subsequent studies when preprocessing pipelines are reused or adapted. Using MIMIC-IV as a case study, we identify and quantify violations of three complementary forms of preprocessing alignment, i.e., temporal, semantic, and population alignment, which manifest as temporal leakage, feature-task misalignment, and biased imputation. We show how ambiguities in timestamp semantics, episode definitions, endpoint construction, modality selection, and missingness handling can alter the information available to a model and affect the interpretation of its predictions. Through analyses of MIMIC-IV data and empirical case studies, we demonstrate that such choices may remain largely invisible in aggregate predictive performance while changing the signals on which models rely. We derive practical recommendations for temporally valid, clinically aligned, and reproducible preprocessing of MIMIC-IV and related electronic health record datasets. The code for our experiments, including our proposed preprocessing, is available at: https://github.com/m2l-lab/mimic-iv-preprocess.

0.22

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.61
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

Making Clinical Language Models Auditable: Concept-Guided Fine-Tuning for Robust Prediction

cs.CL cs.AI ·2026-08-27 ·Jin Mu, Guanhua Chen
top venue similarity 0.60
Abstract

Clinical language models can achieve strong in-hospital accuracy yet fail under deployment shifts because they exploit note-specific artifacts (e.g., templates, separators, boilerplate) that do not reflect patient state. We propose CAST (Concept-guided Artifact Suppression Tuning), an SAE-based framework for auditable clinical text classification. CAST uses Sparse Autoencoders to expose sparse, human-auditable features from intermediate Transformer activations, labels SAE latents with an LLM-assisted interpretation pipeline and ICD-10 retrieval constraints, suppresses verified artifact latents via residual subtraction during fine-tuning, and provides post-hoc per-concept attributions for auditing model decisions. On MIMIC-IV discharge-note mortality prediction, CAST improves over its corresponding fine-tuned encoder baselines and remains competitive with strong LLM baselines, while producing a feature-level audit trail of the clinical concepts that support each prediction and the artifact concepts suppressed during training.

0.44

Why Alzheimer's Speech Screening Fails to Generalize: Bridging the Deployment Gap via Cross-Corpus Evidence Anchoring

eess.AS cs.CLcs.SD ·2026-09-25 ·Zijian Lu, Sizhe Liu, Yin Zhang, Jixuan Deng, Xinrong Lin +4 more
published similarity 0.59
Abstract · Accepted to NCMMSC 2026

Speech-based screening is a promising, non-invasive approach for detecting Alzheimer's disease and related cognitive risks. However, models trained on a single domain often generalize poorly to unseen languages, tasks, or recording protocols. This paper investigates this deployment gap using a leave-one-corpus-out evaluation across four distinct datasets. Among 70 interpretable speech and language features, 59 exhibit direction conflicts between healthy control and cognitive risk groups across corpora, with pause, silence, and speech rate showing high protocol sensitivity. Furthermore, while the XLM-R text baseline achieves strong average performance, its Area Under the ROC Curve (AUC) drops to 0.520 on the weakest held-out domain. A standard GroupDRO baseline reaches a 0.766 mean speaker AUC and a 0.504 worst-domain AUC under the same protocol. To address this, we propose a fusion method that integrates XLM-R text baseline scores with evidence anchors selected during training. Balanced fusion achieves a 0.785 mean speaker AUC, while anchor-heavy fusion raises the worst-case speaker AUC to 0.615. This work highlights the need to audit feature transferability and report worst-case domain robustness in cognitive speech screening.

0.28

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.59
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

A Comparative Explainability Framework for DeBERTa-v3 in Zero-Shot Medical Abstract Classification

cs.AI cs.CL ·2026-10-01 ·Javier Diaz Esteban-Herreros, David Muñoz-Valero, Raquel Martínez-España, Jose M. Juarez, Juan Moreno-Garcia
similarity 0.58
Abstract · 18 pages, 6 figures

A comparative explainability framework is presented to audit DeBERTa-v3 under zero-shot classification of medical abstracts. The work addresses the disagreement problem in Explainable Artificial Intelligence, where different attribution methods produce divergent explanations for the same input and prediction. A natural language inference engine is implemented over the Medical Abstracts corpus with five enriched hypotheses per diagnostic category and a balanced sample of one thousand texts per class. Five explanation methods are compared: SHAP and LIME as model-agnostic approaches, occlusion and Input x Gradient as deep-learning-specific approaches, and Attention x Gradient as a transformer-specific approach. Explanations are standardized through top-token attribution, and pairwise agreement is quantified using the Jaccard index. High predictive accuracy is achieved across well-defined clinical domains, whereas performance degrades under high semantic ambiguity. Explanatory stability directly mirrors predictive certainty, exhibiting strong convergence in univalent categories and a marked drop under diagnostic uncertainty. Furthermore, qualitative error auditing uncovers three systemic failure mechanisms: lexical hypersensitivity, semantic overlap, and loss of attribution coherence. The results support the combined use of several explanation methods and quantitative agreement metrics when auditing transformer-based models in medical text classification, and suggest prioritizing specific clinical ontologies over broad diagnostic labels.

0.21