CS Paper Radar

Unmentioned Checklist Findings Change How Reinforcement Learning Appears to Improve Chest Radiograph Report Checking

Ali Vosoughi, Akhil Kasturi, Chenliang Xu, Axel Wismueller

cs.CV cs.CLcs.LG ·submitted 2026-10-04 18:06 UTC · v1
code/data

Abstract

Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

Comment
40 pages, 7 figures, 17 tables (main text and references pp. 1-19; Supplementary Information as an appendix, pp. 20-40). Submitted to npj Digital Medicine. Code: https://github.com/ali-vosoughi/VerifyGRPO-Rad

Closest papers

Nearest neighbours by meaning across the whole index.

Verification Learning Theory: A Process Model of Checking and Retention in AI-Assisted Judgment

cs.AI ·2026-10-27 ·Christoph Trattner
similarity 0.64
Abstract

Accurate AI assistance can improve immediate judgments while reducing opportunities to practise the operations needed for independent performance. Verification Learning Theory (VLT) formalises this possibility for claim-evaluation practice followed by correct, independent, rule-specific feedback. The model links perceived assistant reliability to evidence checking and links the history of those checks to retained rule use. Its strict form assumes that task demands and perceived reliability influence learning only through checking, with equal learning per genuine check. It therefore predicts that perceived fallibility can improve delayed unaided judgment even without observed assistant errors, and that this advantage disappears when checking is already required and performed. Rule-specific gains and forecasts from checking histories provide further tests. Simulations examine the consequences and parameter dependence of these commitments; they do not constitute empirical validation. Comparisons with depth-of-processing and feedback-encoding accounts identify where predictions diverge and where the accounts remain observationally equivalent. The framework specifies experiments that can test the proposed mechanism and separates retention of practised rules from the broader problem of recognising which rule applies to a new claim.

0.26

CheXPoT: Post-Hoc Visual Verification and Correction of VLM-Generated Radiology Reports

cs.CL cs.CV ·2026-10-31 ·Joey Guo, Rayan Ansari, Alaa Youssef
similarity 0.64
Abstract · 15 pages, 12 figures

Vision-language models (VLMs) have shown promise for chest radiograph report generation, but adoption remains limited because of hallucinated findings that are not grounded in the image. Correcting these hallucinations and improving overall report quality remains a significant challenge. Prior work has addressed this problem by refining models with reinforcement learning, preference optimization, or chain-of-thought supervision, often at substantial compute cost. To address this gap, we introduce CheXPoT, a program-of-thought (PoT) framework that verifies each generated finding against image features and removes those it cannot ground. CheXPoT decomposes generated reports into predicates with RadGraph and an LLM, grounds these predicates against a DenseNet-121 and Grad-CAM visual evidence table, executes PoT verification code, and rewrites reports after removing unsupported predicates. On a 4,145-image held-out split, CheXPoT yields statistically significant precision gains on 8 of 14 CheXpert classes and F1 gains on 5, with no significant decreases in either metric. CheXPoT lifts micro-average precision from 19.2% (MedGemma-4B) to 46.8% (MedGemma-4B + CheXPoT) and micro-average F1 from 23.0% to 49.4%, absolute gains of 27.6% and 26.4% respectively. We also tested CheXPoT on other VLM report generators. On LLaVA-Med, CheXPoT lifts micro-average precision from 4.5% to 17.7% and micro-average F1 from 6.3% to 19.4%. On MAIRA-2, CheXPoT lifts micro-average precision from 15.6% to 42.1% and micro-average F1 from 21.0% to 45.3%. Our results suggest that inexpensive post-hoc visual verification may improve VLM trustworthiness by correcting unsupported findings from generated reports. CheXPoT lays a foundation for tools that help validate VLM-generated radiology reports and reduce unsupported findings. These innovations may subsequently help increase trust and adoption of VLM tools in Medicine.

0.18

Rethinking weakly supervised localization on chest radiographs: position nulls, protocol dependence, and PACE

cs.CV cs.LG ·2026-09-29 ·Shixin Qiu
benchmark similarity 0.62
Abstract

Weakly supervised localization on chest radiographs is reported as a single overlap accuracy, and those numbers are not comparable across papers. We measure what one contains. Against position-null controls that keep a readout's own box and move only its position, class activation mapping and its gradient-weighted variant beat the null on two to four of seven annotated findings on ChestX-ray14 and two of eight on CheXlocalize. The null is beatable: three board-certified radiologists clear it on four to seven. Three rarely stated choices each move a result by more than most reported method effects: the results regime, the extraction threshold, and the mask-to-box rule, whose cost is predicted by how fragmented the thresholded mask is. Predicted box area alone reverses a paired comparison. These measurements produced PACE, for \emph{population anomaly and class evidence}, which multiplies the finding identity from the label-trained head by the spatial evidence from a frozen radiograph backbone that never sees a pathology label. It is the case study that made the protocol dependence visible, and we report its costs beside its gain: in an exploratory matched-area analysis it improves strict-overlap accuracy on both corpora and beats a label-derived second map, but it is the least faithful of the three readouts to the classifier's causal map, its advantage depends on the box rule, and, this benchmark releasing no localization validation set, every design choice behind it was made on the boxes it is scored on. Its one clean transfer beats one baseline and loses to the other.

0.27

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.61
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24

GroundSeek-CXR: Retrospective Evaluation-Guided Active Observation Framework for Multi-Label Chest Radiography Diagnosis

cs.CV ·2026-11-03 ·Yihang Fu, Xinyu Liu, Qing Xu, Xiaofeng Yang, Zhen Chen
similarity 0.60
Abstract

Chest radiography (CXR) diagnosis is critical for thoracic disease assessment, yet challenged by the need to identify subtle lesions and co-occurring abnormalities across regions. While recent vision-language models can actively observe local regions, existing preference-based methods supervise each observation by its immediate effect on the current diagnosis, failing to capture how each observation and stopping decision contributes to the final diagnosis. To address this issue, we propose GroundSeek-CXR, an active CXR diagnosis framework that learns observation and stopping decisions by retrospectively evaluating them with the final diagnosis. Specifically, we first devise a Retrospective Diagnostic Evaluation (RDE) that scores observation and stop candidates from offline Monte Carlo tree search through independent continuations. Moreover, we design a Retrospective Gap-weighted Preference Optimization (RGPO) that learns from retrospective-score preferences weighted by their score gaps, prioritizing actions that improve diagnostic accuracy. Extensive experiments demonstrate that our GroundSeek-CXR framework outperforms state-of-the-art methods, and improves abnormal-image sample-F1 by 4.48% over immediate-score preference learning.

0.18

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.59
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

TRUST: Threshold-Recalibrated Uncertainty-Safe Training for Certified Dismissal in Breast Cancer Screening

cs.CV cs.LG ·2026-08-31 ·Parham Hajishafiezahramini, Matthew Hamilton, Edward Kendall, Gregory Doyle, Oscar Meruvia Pastor
theory similarity 0.59
Abstract

Reducing the review of clearly cancer-negative screening mammograms could lower radiologist workload without compromising cancer detection. We propose a closed-loop threshold-aware training strategy in which the dismissal threshold is recalculated during training and used to penalize cancer-positive images that approach the dismissal region. We evaluated the method on NLBS and RSNA using five controlled training configurations, with case-level assessment based on a one-sided 99\% Clopper--Pearson upper bound for cancer prevalence among dismissed cases. The proposed model achieved the highest case-level dismissal rates at both 98\% and 95\% recall targets. On NLBS, dismissal reached 19.74\% and 21.70\%, while the cross-entropy baseline did not meet either recall target. On RSNA, dismissal improved from 7.04\% to 14.31\% and from 13.49\% to 19.69\%. In external RSNA$\to$NLBS evaluation, the proposed model achieved dismissal rates of 12.95\% and 19.87\% at the 98\% and 95\% recall targets, respectively. These results support closed-loop threshold-aware training for high-recall selective dismissal.

0.26

TrustMed-RL: Long-Horizon Reinforcement Learning for Evidence-Grounded Clinical Diagnosis

cs.AI cs.MA ·2026-10-03 ·Wenxin Zhan, Yizheng Jiao, Haifeng Song, Shuai Xu, Chencheng Pan +2 more
similarity 0.59
Abstract

Medical language models can produce correct diagnoses despite incomplete investigations and unsupported reasoning. To support long-horizon, evidence-grounded diagnosis, we introduce \textbf{TrustMed-RL}. Built from PubMed rare-disease cases and over 24,000 manually annotated image panels, it integrates interviews, examinations, testing, specialist consultation, and literature search through state-dependent actions. Our 8B vision--language policy, trained with clinically adapted GiGPO and coverage-adjusted diagnostic rewards, achieves 37.1\% diagnostic accuracy on 2,500 evaluation cases, outperforming all evaluated open-weight baselines and improving over supervised fine-tuning by 12.4 percentage points.. When success additionally requires acquiring at least 50\% of supporting test evidence, TrustMed-RL achieves 32.5\%, exceeding GPT-4o by 6.8 percentage points. Furthermore, it surpasses all evaluated baselines on MTMedDialog and multiple larger 27--32B models on AgentClinic. In physician review of 200 diagnostically accepted test-set trajectories, 83.0\% receive evidential-grounding scores of 4--5 out of 5. Physicians' assessments suggest that these diagnostic trajectories are trustworthy and aligned with human diagnostic reasoning.

0.16