CS Paper Radar

TRUST: Threshold-Recalibrated Uncertainty-Safe Training for Certified Dismissal in Breast Cancer Screening

Parham Hajishafiezahramini, Matthew Hamilton, Edward Kendall, Gregory Doyle, Oscar Meruvia Pastor

cs.CV cs.LG ·submitted 2026-08-31 19:45 UTC · v1
theory

Abstract

Reducing the review of clearly cancer-negative screening mammograms could lower radiologist workload without compromising cancer detection. We propose a closed-loop threshold-aware training strategy in which the dismissal threshold is recalculated during training and used to penalize cancer-positive images that approach the dismissal region. We evaluated the method on NLBS and RSNA using five controlled training configurations, with case-level assessment based on a one-sided 99\% Clopper--Pearson upper bound for cancer prevalence among dismissed cases. The proposed model achieved the highest case-level dismissal rates at both 98\% and 95\% recall targets. On NLBS, dismissal reached 19.74\% and 21.70\%, while the cross-entropy baseline did not meet either recall target. On RSNA, dismissal improved from 7.04\% to 14.31\% and from 13.49\% to 19.69\%. In external RSNA$\to$NLBS evaluation, the proposed model achieved dismissal rates of 12.95\% and 19.87\% at the 98\% and 95\% recall targets, respectively. These results support closed-loop threshold-aware training for high-recall selective dismissal.

Closest papers

Nearest neighbours by meaning across the whole index.

When Lower Harm Misleads: Auditing Concept Corrections

cs.AI cs.CV ·2026-11-17 ·Tianyou Lai, Wentao Yue, Hongji Li, Chaoyuan Hao, Qilei Li
similarity 0.59
Abstract

An expert who corrects a concept prediction, such as a BI-RADS descriptor in breast ultrasound, expects the diagnosis to improve. Objectives that reduce the harm of such corrections are judged by harm and accuracy, yet harm also falls when a model responds less to every correction or starts from a worse uncorrected prediction, the reference for harm. We propose a correction audit, a reproducible evaluation protocol that separates these explanations: it splits each correction into harm and useful gain on identical events, separates the starting prediction from the correction response, and compares objectives with amplitude baselines matched in source harm. On three breast-ultrasound sources, worst-case correction training, evaluated from the mean-case model's start, lowers harm but gives up more useful gain in all 21 source comparisons pooled over six seeds, raising the corrected negative log-likelihood (NLL); from the same start, selecting between the objectives by harm picks the less helpful model on all three sources. On CUB, a monotonic harm penalty at its reported weight lowers path-level harm in all 80 concept sets while raising the NLL in all 80, almost entirely before any correction. At a fixed start, rescaling both responses to the same source harm reproduces the penalty's mean harm, useful gain and NLL on single-concept corrections within a prespecified margin of 0.0005 nat, although the two responses point in different directions. Lower harm therefore signals better corrections only when it is read together with useful gain, absolute risk and the start it is measured from.

0.36

Unmentioned Checklist Findings Change How Reinforcement Learning Appears to Improve Chest Radiograph Report Checking

cs.CV cs.CLcs.LG ·2026-10-04 ·Ali Vosoughi, Akhil Kasturi, Chenliang Xu, Axel Wismueller
code/data similarity 0.59
Abstract · 40 pages, 7 figures, 17 tables (main text and references pp. 1-19; Supplementary Information as an appendix, pp. 20-40). Submitted to npj Di…

Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

0.54

TrustMed-RL: Long-Horizon Reinforcement Learning for Evidence-Grounded Clinical Diagnosis

cs.AI cs.MA ·2026-10-03 ·Wenxin Zhan, Yizheng Jiao, Haifeng Song, Shuai Xu, Chencheng Pan +2 more
similarity 0.56
Abstract

Medical language models can produce correct diagnoses despite incomplete investigations and unsupported reasoning. To support long-horizon, evidence-grounded diagnosis, we introduce \textbf{TrustMed-RL}. Built from PubMed rare-disease cases and over 24,000 manually annotated image panels, it integrates interviews, examinations, testing, specialist consultation, and literature search through state-dependent actions. Our 8B vision--language policy, trained with clinically adapted GiGPO and coverage-adjusted diagnostic rewards, achieves 37.1\% diagnostic accuracy on 2,500 evaluation cases, outperforming all evaluated open-weight baselines and improving over supervised fine-tuning by 12.4 percentage points.. When success additionally requires acquiring at least 50\% of supporting test evidence, TrustMed-RL achieves 32.5\%, exceeding GPT-4o by 6.8 percentage points. Furthermore, it surpasses all evaluated baselines on MTMedDialog and multiple larger 27--32B models on AgentClinic. In physician review of 200 diagnostically accepted test-set trajectories, 83.0\% receive evidential-grounding scores of 4--5 out of 5. Physicians' assessments suggest that these diagnostic trajectories are trustworthy and aligned with human diagnostic reasoning.

0.16

Less Annotation, More Interpretation: Prior-Guided Concept Bottleneck Models for Interpretable Cancer Imaging Diagnosis

cs.CV ·2026-08-13 ·Baoqiang Ma, Kenneth Gilhuijs
published similarity 0.56
Abstract · Accepted at the iMIMIC Workshop at MICCAI 2026

Concept bottleneck models (CBMs) can improve the transparency of cancer image diagnostic prediction by expressing predictions through radiological concepts. However, their dependence on instance-level concept annotations limits practical applicability. We propose a prior-guided hybrid CBM that integrates limited concept annotations, class-conditional concept distribution matching on unannotated patients, and prior initialization of the concept-to-diagnosis head. We evaluate the method on CBIS-DDSM mammographic masses and calcifications and LIDC-IDRI pulmonary nodules across 0-100% concept annotation. In the clinically relevant 0-20% annotation regime, the hybrid CBM consistently improves mean concept AUC over a matched standard CBM, while maintaining diagnostic performance close to black-box models. At 10% annotation specifically, concept AUC increases from 0.619 to 0.741 for masses, from 0.650 to 0.787 for calcifications, and from 0.597 to 0.642 for pulmonary nodules. Ablation experiments identify prior initialization as the main component contributing to improved concept detection, likely by stabilizing the concept-to-diagnosis head. Zero-shot VLMs remain insufficient for reliable fine-grained tumor-level concept prediction. These findings suggest that structured priors can substantially reduce the annotation burden of interpretable cancer imaging models.

0.18

Beyond AUC: Do Mammography Risk Models Predict When Cancer Occurs?

cs.CV q-bio.QMeess.IV ·2026-11-15 ·Svetlana Krasnova, Andrey Krylov, Dmitry Sorokin
similarity 0.56
Abstract · 7 pages, 2 figures, 1 table. Submitted to ISBI 2027

Longitudinal deep learning models for mammography-based breast cancer risk prediction output either per-year cumulative risks or a discrete distribution over the year of diagnosis, from which cumulative risks F1,...,F5 are derived. These models are evaluated almost exclusively with year-wise AUCs and the concordance index. We show that these metrics are largely insensitive to when cancer occurs: they can be high even for a model that carries no information about the year of diagnosis. We re-evaluate two recent longitudinal models (OA-BreaCR, LMV-Net) on CSAW-CC with a 5-year horizon using timing metrics computed on cancer cases only. Despite C-indices up to 0.75, neither orders cancer cases by time to diagnosis significantly better than chance (c_time 0.51 and 0.55, both 95% CIs covering 0.5). Weighted absolute timing error favours a constant "year 3" prediction over both models, so we use c_time as the primary timing metric. For Mirai's additive-hazard head, also used by LMV-Net, we analyse how per-year increments passed through a ReLU can collapse under severe class imbalance. We also propose a breast-level, two-stage model that separates whether from when. It matches LMV-Net in discrimination (C-index 0.745 vs. 0.746) but orders cancer cases better (c_time 0.58 vs. 0.51, paired 95% CI of the difference 0.01-0.13), on par with Mirai's published weights (0.57).

0.21

Foundation model embeddings capture pre-diagnostic changes on screening mammograms

cs.CV cs.LG ·2026-09-22 ·Kalina P. Slavkova, Eric Brattain, Aditya Gowd, Akash Pattnaik, Jean-Benoit Delbrouck +4 more
similarity 0.56
Abstract · 13 pages, 5 figures, supplementary info attached

Foundation model embeddings of screening mammograms may encode pre-diagnostic tissue change without task-specific adaptation. We tested whether embeddings move faster along a data-derived "cancer direction" in women later biopsied for cancer than in matched screen-negative controls, and whether this depends on pretraining domain. We studied 1,773 biopsied women (785 malignant, 988 biopsy-negative) and 1,773 matched controls, each with at least two annual screening exams before their index exam. An identical pipeline was applied to four 2D models: Mammo-CLIP (MC, out-of-distribution mammography), HOPPR (in-distribution mammography), MedImageInsight (MII, general medical imaging), and BiomedCLIP (biomedical vision-language pretraining on literature figures). Breast-level embeddings quantified longitudinal movement along the cancer direction. We compared cases and controls using a between-patient design with complementary mixed-effects analysis, and biopsied versus healthy contralateral breasts within patients. Under matched modality in MII embedding space, malignant cases drifted significantly faster than controls in the first two screening intervals preceding the index exam; biopsy-negative cases showed significance only in the first. MC differences were significant in the first interval for both biopsy groups. Within-patient comparisons showed a broadly similar pattern, with MC significance extending to the second interval in both groups and HOPPR showing significance at interval 1. BiomedCLIP showed no significant differences in either design or biopsy group. Overall, directional embedding velocity emerges as a property of clinically grounded rather than general biomedical pretraining, showing that foundation model embeddings can encode pre-diagnostic mammographic change without task-specific adaptation.

0.37

MammoMix: Leveraging Mixture of Experts for Robust Mammogram Breast Detection

cs.CV ·2026-08-11 ·Dinh Tan Nguyen, Hoang Quan Dang, Chen Zhang, Sai Ho Ling
published similarity 0.56
Abstract · Australasian Joint Conference on Artificial Intelligence 2025

Breast lesion detection in mammography remains a challenging task due to variations in image quality, lesion appearance, and population demographics across datasets. While current object detectors such as YOLO and DETR achieve strong results on individual datasets, their performance often degrades when trained on or applied across heterogeneous sources. To address this, we propose MammoMix, a novel framework based on Mixture-of-Experts (MoE) paradigm for robust and generalizable lesion detection. In MammoMix, each expert model is trained on a specific domain, allowing it to specialize in distinct characteristics of its source data. A gating mechanism adaptively weighs contributions from each expert based on input image, combining their outputs to enable domain-adaptive inference. To improve reliability, we further incorporate a calibration module, MoCAE, which adjusts confidence scores to reflect true predictive uncertainty. We evaluate MammoMix on 3 public mammography datasets: CSAW, DDSM, and DMID, covering diverse clinical settings. Results show that MammoMix outperforms baseline detectors in both average precision and reliability, particularly on datasets with greater variability. Our findings demonstrate that expert specialization and calibrated ensemble fusion significantly enhance model generalization and robustness. MammoMix offers a promising step toward dependable AI-assisted breast cancer screening across real-world clinical domains.

0.52

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.56
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21