CS Paper Radar

When Lower Harm Misleads: Auditing Concept Corrections

Tianyou Lai, Wentao Yue, Hongji Li, Chaoyuan Hao, Qilei Li

cs.AI cs.CV ·submitted 2026-11-17 02:10 UTC · v1

Abstract

An expert who corrects a concept prediction, such as a BI-RADS descriptor in breast ultrasound, expects the diagnosis to improve. Objectives that reduce the harm of such corrections are judged by harm and accuracy, yet harm also falls when a model responds less to every correction or starts from a worse uncorrected prediction, the reference for harm. We propose a correction audit, a reproducible evaluation protocol that separates these explanations: it splits each correction into harm and useful gain on identical events, separates the starting prediction from the correction response, and compares objectives with amplitude baselines matched in source harm. On three breast-ultrasound sources, worst-case correction training, evaluated from the mean-case model's start, lowers harm but gives up more useful gain in all 21 source comparisons pooled over six seeds, raising the corrected negative log-likelihood (NLL); from the same start, selecting between the objectives by harm picks the less helpful model on all three sources. On CUB, a monotonic harm penalty at its reported weight lowers path-level harm in all 80 concept sets while raising the NLL in all 80, almost entirely before any correction. At a fixed start, rescaling both responses to the same source harm reproduces the penalty's mean harm, useful gain and NLL on single-concept corrections within a prespecified margin of 0.0005 nat, although the two responses point in different directions. Lower harm therefore signals better corrections only when it is read together with useful gain, absolute risk and the start it is measured from.

Closest papers

Nearest neighbours by meaning across the whole index.

Auditing black-box clinical prediction models with a large language model through queries alone: a blinded test with planted flaws

cs.LG cs.AI ·2026-11-18 ·Zhiyu Liu, Xinyu Yang
code/data similarity 0.64
Abstract · 15 pages, 2 figures, 6 tables. Models, prompts, replies with tool calls, and code: https://github.com/Chth1z/llm-black-box-model-audit

Large language models (LLMs) are used to explain clinical prediction models, on the promise that they can say what a model computes, find its faults and even reveal new knowledge in it. We tested the three promises where the answers could be checked. From the International Stroke Trial we trained four kinds of model (logistic regression, explainable boosting machine, gradient-boosted trees, neural network) for two outcomes on patients randomised earlier, planted one flaw in each of 24 copies (an under-predicted subgroup, a reversed risk factor or an implausible step) and mixed them with the 8 clean models. GPT-6 Astra audited each model three times, blind, through a tool that only returned the model's predictions; the judging rules were committed before any run and applied by program. Its surrogate models, with a median of 128 terms, reproduced the audited models' log-odds with a mean $R^2$ of 0.976 (0.959 for an additive surrogate of 42 terms fitted by an analyst). It found the planted flaw in 69 of 72 runs (96%; 95% CI 80% to 99%); a script written for the purpose found all 24. It also reported many more problems: 60% of 1,089 checkable reports failed the pre-specified check against the model's average behaviour; post hoc, most of these were real but small steps, and 15% of the checkable reports were not found in the model. Of 601 unexpected relationships it read out of the clean models, 11% held in patients randomised later (random pairs 6%; a regression scan's shorter list of its strongest candidates, 28%); after a check on the training data, 33% against 30%. With query access alone, an LLM can describe a black-box model faithfully and find nearly every planted flaw, as a purpose-written script also did; its reports of problems must be checked on the model and its discoveries on data.

0.23

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.63
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30

TAME: Token Attribution and Masking for Emergent misalignment

cs.LG cs.AIcs.CL ·2026-09-15 ·Md Rayhanul Masud, Md Rizwan Parvez
similarity 0.62
Abstract · Accepted at EMNLP UncertaiNLP Workshop 2026

Fine-tuning an aligned language model on narrow, flawed data can induce harmful behavior far outside the training domain, known as emergent misalignment (EM). Prior work has localized EM in model weights, activations, and training documents, but it remains unclear which training tokens carry the relevant fine-tuning signal. We introduce TAME (Token Attribution and Masking for Emergent Misalignment), a three-stage framework: token attribution scores how strongly the fine-tuning update raises each response token's likelihood, using forward passes through a released LoRA adapter; signal characterization finds patterns among high-attribution tokens; and causal validation tests them by attribution-guided loss masking. On released EM organisms and a 6,849-example medical-advice split, attribution is concentrated (the top 5% of tokens hold 32% of the mass) and, in Llama, depleted for medical vocabulary but enriched for a register of unwarranted certainty, even after controlling for token rarity. Masking high-attribution tokens during fresh fine-tuning cuts EM by 23x in Llama and 36x in Qwen, with the perplexity cost concentrated on the targeted register rather than on medical content; an equal random mask leaves EM unchanged. In Llama, the attribution pattern suggests that EM-relevant signal lies more in how confidently flawed content is expressed than in its domain vocabulary; the causal masking effect itself holds across both model families.

0.53

CHARTER: Auditing Reference Substitution in Hierarchical Compact-Evidence Evaluation for Computational Pathology

cs.CV cs.LG ·2026-10-06 ·Hyun Do Jung, Jungwon Choi, Soojung Choi, Yujin Oh, Hwiyoung Kim
similarity 0.62
Abstract

In digital pathology, compact evidence is often used to explain or audit predictions made by whole-slide image multiple instance learning models. In hierarchical compact-evidence pipelines, candidate filtering introduces a strategy-specific candidate-conditioned prediction alongside the original full-bag prediction. If the evaluation reference changes while the intended target remains the original full-bag prediction, however, not only can the measured fidelity of the same compact evidence change, but comparisons between competing candidate strategies can also change. To make this dependence explicit, we introduce CHARTER, a reference-aware evaluation charter that asks researchers to DECLARE the intended target and reference, QUANTIFY candidate-induced prediction shift, and AUDIT the stability of comparative conclusions. Across the 15 comparisons in our main five-seed Random-K audit, 4 showed determinate reversals; in a matched native-ranking stress test, the ACMIL comparison changed from REVERSED to PRESERVED. CHARTER turns otherwise implicit candidate-filtering and reference choices into an auditable evaluation specification, helping distinguish genuine preservation of the intended prediction from apparent gains induced by changing the prediction being explained.

0.17

Accuracy Is Not Risk: Why Medical AI Should Not Report Only Its Most Likely Label

cs.CY stat.MEcs.LGstat.AP ·2026-10-31 ·Jeffrey Humpherys, Makoto Jones
similarity 0.61
Abstract

Background. Many medical AI models are trained to reproduce a single reference label and hand the most likely label to the next step in a clinical workflow. A classifier can select that label correctly while providing an inadequate summary for estimating downstream risk. Methods. We use Jeffrey's rule of conditioning to specify when probabilities over intermediate states, such as diagnoses or imaging categories, can be carried forward to an outcome risk. We separate two errors of reporting only the most likely label, discarding the probability of the other states and applying the risk of patients who have the leading diagnosis to a patient who only probably has it. We also give conditions under which the label and the full distribution lead to the same decision, and we propose guardrails for device developers, regulatory reviewers, and health insurers. Results. In a hypothetical chest-pain differential, reporting only the benign leading diagnosis greatly understates the patient's risk of death or cardiac arrest, so a patient who warrants evaluation could be discharged or denied imaging. In a hypothetical BI-RADS example, the most likely category is "probably benign," yet the propagated malignancy risk exceeds the ceiling that defines that category. Conclusions. A predicted label is not an observed state, and a calibrated classifier is not automatically a valid outcome model. Clinical and insurance coverage decisions should rest on the patient's outcome risk, judged against a threshold justified by the consequences of acting and not acting. Developers should state what each model output means and check that every step between the model and the decision preserves the patient's risk.

0.07

TRUST: Threshold-Recalibrated Uncertainty-Safe Training for Certified Dismissal in Breast Cancer Screening

cs.CV cs.LG ·2026-08-31 ·Parham Hajishafiezahramini, Matthew Hamilton, Edward Kendall, Gregory Doyle, Oscar Meruvia Pastor
theory similarity 0.59
Abstract

Reducing the review of clearly cancer-negative screening mammograms could lower radiologist workload without compromising cancer detection. We propose a closed-loop threshold-aware training strategy in which the dismissal threshold is recalculated during training and used to penalize cancer-positive images that approach the dismissal region. We evaluated the method on NLBS and RSNA using five controlled training configurations, with case-level assessment based on a one-sided 99\% Clopper--Pearson upper bound for cancer prevalence among dismissed cases. The proposed model achieved the highest case-level dismissal rates at both 98\% and 95\% recall targets. On NLBS, dismissal reached 19.74\% and 21.70\%, while the cross-entropy baseline did not meet either recall target. On RSNA, dismissal improved from 7.04\% to 14.31\% and from 13.49\% to 19.69\%. In external RSNA$\to$NLBS evaluation, the proposed model achieved dismissal rates of 12.95\% and 19.87\% at the 98\% and 95\% recall targets, respectively. These results support closed-loop threshold-aware training for high-recall selective dismissal.

0.26

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

cs.LG ·2026-11-06 ·Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner +3 more
similarity 0.59
Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

0.21

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.59
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10