Price-Optimized EV and Heat-Pump Scheduling Can Exceed Uncoordinated Feeder Peaks

Tatjana Hein, Lukas P. Wagner, Alex Bernhard, Felix Ocker

eess.SY ·submitted 2026-10-05 07:32 UTC · v2
publishedcode/data

Abstract

Electric vehicles and heat pumps add large, time-flexible loads to low-voltage feeders. When each household independently minimizes its own charging cost against the same electricity price, this flexible demand piles into the cheapest hours, and the resulting synchronization can stress the feeder more than uncoordinated operation does. This work quantifies that effect on a rural low-voltage feeder with photovoltaics (97 buses, 250 kVA transformer) in 913 simulation runs that compare seven strategies across four seasons, device penetrations of up to 90 %, 208 price weeks from 2022-2025, and heterogeneous heat pumps. At 30 % penetration of each device, this decentralized cost minimization drives the transformer to 253 % of rated capacity, more than three times the peak of non-optimized Fixed-random charging with the same mobility and charged energy, and 478 % with electric vehicles alone at 90 % penetration, with undervoltage at the far end of the longest feeder arm. It exceeds Fixed-random and Fixed-times charging in every winter, spring, and autumn price week, and each 30 pp of heat-pump penetration raises its peak by about 110 pp, twelve times as much as without optimization. Centralized peak minimization removes all demand-driven violations. In the heat-pump-free summer case at 60 % photovoltaics, midday reverse power flow sets a transformer floor of 128.9 % that no strategy undercuts, since no commuting electric vehicle is at home at the export peak. With a time-variable grid fee added to the spot price, the weekly peak of decentralized cost minimization falls into the reduced-fee window in 99 of the 104 fee-active price weeks, compared with 53 without the fee, while keeping at least 89.8 % of its height, so the fee relocates rather than removes the synchronization. The simulation and optimization code is available at https://github.com/lukas-wagner/SynchronizationEffectsAnalysis.

Comment
Accepted at 2026 IEEE IES ONCON

Closest papers

Nearest neighbours by meaning across the whole index.

Who Gets the Grid Capacity? Allocating Dynamic Access Among Multiple Virtual Power Plants

eess.SY ·2026-11-16 ·Nakul Sreekanth, Jun He, Andrew L. Liu, S. Sivaranjani
similarity 0.67
Abstract

Virtual power plants (VPPs) trade in the same wholesale market and share distribution lines and transformers, and uncoordinated, profit-maximizing VPPs can push a shared transformer past its thermal limit or drive a feeder voltage out of band. The utility, which only observes the front-of-the-meter net injection at each bus, must keep the network safe from that net injection alone. We allocate a 24-hour active and reactive operating envelope to each VPP by a Benders decomposition: the utility sets a trial envelope, each VPP solves its private convex portfolio problem, and the returned value and dual gradient become supporting cuts that rebuild its value function while its schedule, state, and cost stay private. The envelope carries the transformer's thermal state across hours, bounds a joint conditional value-at-risk over forecast uncertainty, and is re-optimized each hour with the current hour committed. On a reduced IEEE-13 feeder with real load and prices, an active-power-only implementation lowers the transformer's peak-temperature CVaR from 254 to 97\,$^\circ$C at a 28\% value give-up and holds the transformer below its limit where nameplate access breaches it.

0.29

Prosumer Synchronisation Risk: Impacts of Time-Varying Tariffs on Distribution Network Expansion

eess.SY ·2026-09-02 ·Dillon Zadoks, Alfredo Oneto, Carlo Tajoli, Yi Guo, Philipp Heer +2 more
published similarity 0.61
Abstract

The rapid deployment of distributed energy resources, including heat pumps, electric vehicles, photovoltaics, and battery storage, is reshaping the operation of low-voltage networks. While distribution system operators often aim to develop time-varying tariffs to incentivise network-friendly behaviour and defer reinforcements, they risk triggering prosumer synchronisation. As prosumers follow price signals, their behaviour may synchronise, avoiding existing load peaks while creating undesirable peaks at other times. This paper quantifies the impact on low-voltage network reinforcement needs when shifting from flat tariffs to two time-varying tariffs: Time-of-Use and Real-Time Pricing. Applying a mixed-integer linear model across 471 low-voltage reference networks in Switzerland, we evaluate expansion requirements under projections of distributed energy resource deployment for 2050. In the model, prosumers operate their distributed energy resources in accordance with their subscribed electricity tariff to minimise costs, and the distribution system operator subsequently optimises reinforcements. Our results demonstrate that while adopting time-varying tariffs can reduce reinforcement investment costs by more than 50%, high adoption rates can reverse this declining trend. Specifically, once prosumer adoption exceeds the optimal thresholds of 50% for Time-of-Use and 40% for Real-Time Pricing, reinforcement needs increase by 39% and 134%, respectively, for an additional 20% of tariff adoption.

0.24

Robust Joint Planning of EV and eBus Charging Infrastructure with PV Self-Consumption under Demand Uncertainty

eess.SY ·2026-08-19 ·Biswarup Mukherjee
benchmark similarity 0.59
Abstract · This manuscript has been submitted for peer review

This paper presents a mixed-integer linear programming (MILP) framework for joint electric vehicle (EV) and electric bus (eBus) charging-infrastructure planning with photovoltaic (PV) self-consumption. The model co-optimizes charger siting, sizing, technology selection, eBus-to-depot assignment, and hourly charging schedules. A deterministic MILP is first formulated as a nominal benchmark and then extended to a scenario-based robust min--max formulation under vehicle energy-demand uncertainty. The robust model uses shared first-stage infrastructure decisions and scenario-specific operating decisions, and minimizes infrastructure cost plus the worst-case scenario operating cost through an epigraph reformulation. Soft-feasibility penalties quantify unmet charging energy, terminal state-of-charge (SOC) shortfall, and capacity violations under stressed scenarios. A 50-node case study shows that route-segment eBus demand and PV weighting alter charger deployment, technology mix, and grid import, while V2G enables hard-feasible robust operation at sufficiently large penalty weights. These results highlight that effective long-term infrastructure planning must simultaneously account for diverse vehicle fleets, operational strategies that adapt to different scenarios, and node-level constraints on charging capacity.

0.19

Analyzing Simultaneous Charging Factors of Electric Vehicles Using Monte Carlo Simulation: A Case Study in Phu Quoc City, Vietnam

eess.SY ·2026-11-04 ·Tien Khai Nguyen, Trong Nghia Le
published similarity 0.59
Abstract · 11 pages, 17 figures. Accepted for publication in GMSARN International Journal (expected in Issue 3, 2027). Author-prepared accepted manuscr…

This study estimates the simultaneous charging factor (SCF) of electric vehicles (EVs) in Phu Quoc City, Vietnam, using a Monte Carlo simulation. Three planning scenarios (2030, 2035, and 2040) are developed from population-based EV uptake assumptions and vehicle-specific charging probability profiles over 24 hours, reflecting distinct operating patterns of motorbikes, cars, taxis, and buses. For each vehicle class and scenario, 1,000 simulation runs are performed to compute SCF and its uncertainty, reported via 95% confidence intervals. Results indicate that SCF decreases as EV penetration increases, implying more temporally dispersed charging demand and a reduced likelihood of extreme coincidence. For electric buses, SCF declines from 0.76 (2030) to 0.59 (2040), and other vehicle groups show similarly decreasing trends across the horizon. These SCF estimates provide practical inputs for grid-aware charging infrastructure planning, including diversity factors for sizing distribution transformers and feeders, identifying peak-hour stress, and informing demand management measures such as time of use tariffs and basic smart charging controls.

0.68

Degradation Aware V2G Dispatch for Co-Optimization of Parking Facility and Edge Data Center Located in the Airport Campus

eess.SY ·2026-10-17 ·Abdullah Al Mehadi, Hamed Haggi, Chinmay Morankar
similarity 0.57
Abstract

This paper studies an airport campus where long stay EV parking, airport buildings, and an AI data center share a single grid connection. The campus pays a commercial electricity tariff that charges for both the energy used and the highest power drawn during peak hours. Parked EVs can send power back to the campus through vehicle to grid (V2G) chargers and lower this peak. This paper proposes a two stage method. In the first stage, a linear program schedules EV charging and discharging to maximize the operator's profit and also sets a fixed daily payment to EV owners. In the second stage, a search chooses the share of energy savings paid to owners. The model guarantees that every owner is paid enough to take part, pays for battery wear so that EVs discharge only when it is worth the wear, and assigns charging ports on a first come, first served basis. In the case study, 400 V2G chargers are added to 1200 existing Level 2 chargers, serving 5000 expected sessions under summer and winter rates. In a summer week, V2G raises operator profit by $4978 compared with smart charging and lowers the high peak demand by 4400 kW (9%). The best contract gives owners 70% of the energy savings and earns 21% more than a fixed payment alone. Doubling the V2G ports to 800 lowers the peak further but reduces profit, because owner payments grow faster than the savings. V2G pays back within 10 years if a bidirectional charger costs less than about $1800 more than a standard one. Compared with a 5 MW/10 MWh stationary battery, V2G cuts more peak demand at $409 of investment per kW instead of $1522 and needs no extra land, while the battery does not pay back within its lifetime.

0.30

Co-optimizing Bidding and Power Allocation of an EV Aggregator Providing Real-time Frequency Regulation Service

eess.SY ·2026-08-25 ·Ruike Lyu, Hongye Guo, Kedi Zheng, Mingyang Sun, Qixin Chen
top venuehighly cited similarity 0.56
Abstract · Published in: IEEE Transactions on Smart Grid ( Volume: 14, Issue: 6, November 2023)

The rapidly expanding scale of electric vehicle (EV) fleets and continuously decreasing battery costs are making vehicle-to-grid services a reality. In this paper, we study the interaction between the problems of an EV aggregator's bidding in the regulation market and power allocation (i.e., determining the (dis)charging powers of the EVs in regulation deployment). Although the two problems are coupled, they are often regarded as decoupled and optimized separately for complexity issues. However, failing to consider the coupling of bidding and power allocation can lead to a decline in the profit of the EV aggregator (EVA). In this paper, we propose a framework for co-optimizing EVA bidding and power allocation in the regulation market. The bidding model is formulated as a stochastic programming problem with embedded power allocation in discretized regulation signal scenarios. To meet the solution time requirement for regulation deployment, we further propose a power allocation model that can be solved online. It utilizes the Lagrange multipliers from the bidding problem to ensure that the allocation results correspond to the optimal solution of the bidding problem. The effect of the proposed framework on improving EVA profits and reducing degradation costs is verified in the case study.

0.67

Benefits of Dynamic Thermal Rating for Distribution Transformers Under Accelerated Load Growth

eess.SY ·2026-09-28 ·Wenbo Wang, Killian McKenna, Francisco de Leon, Haowei Lu, Xin Fang
unusual similarity 0.55
Abstract · 5 pages, intend for conference

Dynamic Thermal Rating (DTR) has been widely applied to transmission lines for congestion management, but its potential for distribution transformers is less explored. By adjusting equipment ratings based on real ambient and operating conditions, DTR allows transformers to operate above conservative static nameplate values without compromising asset health. This paper evaluates how DTR can serve as a non-wires alternative to traditional upgrades in distribution systems facing accelerated load growth. Using an example feeder from the SMART-DS dataset, we compare conventional transformer replacement strategies against DTR-enabled operation with ambient-adjusted ratings. The results demonstrate that DTR can defer a significant number of transformer upgrades and reduce annual upgrade costs. More broadly, DTR is most effective in regions with pronounced weather diversity, peak demand occurring during cooler periods, or sustained load growth that would otherwise trigger costly reinforcements. These findings show that DTR is a practical and cost-effective option for utilities, provides both operational flexibility and investment deferral opportunities, and offers a foundation for developing distribution-level DTR programs.

0.27

A Critical Review of Grid Integration Challenges and Flexibility Opportunities for Large-Scale Data Centers

eess.SY ·2026-10-14 ·Bibek Dhakal, Manohar Chamana, Biswambhar Gayen, Jatendar Kumar, S M Shams Rahman +5 more
similarity 0.55
Abstract

The rapid proliferation of cloud computing and artificial intelligence workloads is fundamentally reshaping the magnitude, spatial concentration, and electrical characteristics of data center power demand. Data centers differ from conventional commercial loads because they combine high rack densities, converter-dominated interfaces, thermally coupled cooling, uninterruptible power supplies, programmable workloads, and increasingly complex behind-the-meter generation and storage within a single facility. This review examines their grid integration from utility and sustainable-energy perspectives across resource planning, large-load interconnection, distribution feeders, market operation, real-time dynamics, power quality, and asset management. Particular attention is given to distribution-level issues that receive limited treatment in broader energy reviews: bidirectional operation on renewable-rich feeders, harmonic propagation and resonance, ride-through and reconnection, transformer derating, cable ampacity, neutral-conductor heating, protection, and measurement. Static, composite, physics-based dynamic, calibrated, impedance, electromagnetic transient, and hybrid load models are compared according to study purpose and data requirements, and utility coordination platforms, uninterruptible power supply and battery control, workload flexibility, renewable co-location, cogeneration, fuel cells, thermal storage, and clean firm supply are assessed. The central finding is that requested peak demand and annual energy matching alone cannot establish reliable or sustainable integration. Credible assessment must consider hourly and locational supply, network deliverability, marginal emissions, lifecycle and water impacts, backup obligations, rebound, asset health, and verified operating capability.

0.12