CS Paper Radar

Choosing an energy-efficient software architecture for building system diagnostic support

Roxane Koitz-Hristov, Franz Wotawa

cs.SE cs.AI ·submitted 2026-10-05 14:49 UTC · v1

Abstract

Around 30\% of global energy expenditure can be attributed to the building sector, where a large portion of energy-consumption could be avoided by repairing existing faults. Fault detection and diagnosis (FDD) software addresses this issue; however, its creation and operation also have an environmental impact. The magnitude of this impact is influenced by the diagnosis architecture, as different architectures and methods have different energy demands. Yet, simply considering the energy consumed by the software itself is not sufficient to assess its overall environmental impact, since the diagnostic performance, e.g., number of detected faults or number of faults missed, also contributes to its ecological footprint. In this paper, we propose an energy-consumption model that considers FDD performance and energy spend directly by the diagnosis software. In an initial experiment, we compare several FDD architecture families, i.e., rule-based, model-based, classical machine learning, and large-language-model-based, in simulation using performance and energy-consumption values collected from prior literature. The results show that considering the computational energy and accuracy of FDD can change the relative benefit of the different approaches. Computationally efficient machine learning methods, such as random forest, provide the largest net savings on smaller buildings, whereas more resource-intensive approaches, such as fine-tuned large language models, become advantageous as building size increases. Our findings suggest that overall energy efficiency depends not only on the computational demand of the FDD software, but also on its diagnostic performance and the scale of the building.

Closest papers

Nearest neighbours by meaning across the whole index.

From Grey-Box to Green-Box: When can Physics-Informed Machine Learning Reduce Carbon Footprints in Structural Health Monitoring?

cs.LG ·2026-09-27 ·Daisy R. Bradley, Nathan A. Hinchliffe, Daniel J. Pitchforth, Matthew R. Jones, Elizabeth J. Cross
similarity 0.61
Abstract · 27 pages, 15 figures

Machine learning plays an increasingly vital role in engineering, but the corresponding increase in compute time is not without environmental cost. Physics-informed machine learning or "grey-box" models have been developed to overcome some of the limitations of traditional black-box learners, utilising the physical insight that an engineer would have about the structure they are modelling and have shown promising results in the structural engineering field among many others. This work explores whether an additional advantage could be a reduced environmental impact, considering the relationship between training data quantity and training time, linking this duration to carbon emissions from computing. In a structural health monitoring context, four physics-informed machine learning approaches - spanning Gaussian processes and neural networks - are evaluated: residual modelling, input augmentation, hybrid modelling, and constrained learning. The emissions for training each of the models to reach a given error threshold is compared, and in most examples, shown to be lower for the physics-informed models (with input augmented models being an exception). This reduction in training emissions further compounds the environmental savings achieved by collecting and storing less data. Although promising results, we cannot expect a silver bullet and the case studies demonstrate that a trade-off is needed between the increased complexity that comes from introducing physics into a machine learner, against the gain from reduced training data requirements.

0.23

Where Can a Decision Model Diagnose HVAC Faults? Reasoning Demand, Physical Representation, and Robustness Under Shift

cs.AI ·2026-10-07 ·Wooyoung Jung
similarity 0.60
Abstract · 58 pages, 4 figures, 12 tables. Submitted to Energy and Buildings

Artificial intelligence supports building operations in several forms, each with its own barrier. Expert rules must be tuned for every system, supervised models need labeled data that buildings rarely record, and language models return free text that requires human-in-the-loop checking, since their stated confidence is unreliable. A newer kind of pretrained model, here called a decision model, returns a probability for every allowed answer, so one model could serve many decisions without training. This study answers three open questions for fault diagnosis in heating, ventilation, and air-conditioning systems: which decisions such a model can make, what input it needs, and whether its probabilities hold when conditions change. On 128 fault days from four public datasets of real equipment, faults are graded by the reasoning their diagnosis demands, with data given raw, as physical features, or with Brick topology. The decision model Jev, open language models, and a supervised model face nine tests that change season, control configuration, or building. Given physical features, Jev and the larger open model diagnosed faults whose evidence one feature carries, but not faults that need operating context. Under shift they kept their accuracy and calibration, while the supervised model lost 0.33 macro-F1 yet led or tied within a building. Their probabilities still needed correction, and detection was weak. The study maps which faults a decision model can diagnose and from what input, and supports a division of work in which code computes the physics and the model ranks candidate faults for an operator.

0.63

Can LLM Agents Efficiently Identify Appliance Faults? Insights From Diagnosing a Simulated Appliance

cs.CL ·2026-10-13 ·Lucas H. McCabe, Sarah Lukens, H. Howie Huang
benchmark similarity 0.59
Abstract

In so-called "Industry 4.0," integrated sensors, analytics tools, and other digital technologies supplement industrial workflows, potentiating enhanced visibility and automation. Prognostics and health management (PHM) and natural language processing (NLP) practitioners alike have explored the application of large language models (LLMs) to industrial asset management, but many prior works' focus on exam-like benchmarks has limited their assessment of LLMs' ability to automate practical operations. Herein, we introduce CoffeeBench, a fault diagnostics task for LLM agents, using a simulated appliance. The LLMs we evaluate struggle to consistently identify faults from the sensor information alone, but the best-performing ones can iteratively refine the fault-option space to eventually obtain a successful diagnosis. Our subsequent analyses, therefore, focus on: differentiating models by diagnostic efficiency (RQ1); examining the lagging performance of the three worst models (RQ2); and identifying viable heuristics for selective prediction (RQ3), including that initial diagnostic uncertainty and LLM-judged soundness of reasoning are high-signal predictors of diagnostic success. In addition to our benchmark results (Section 3.1), we provide practical insights for improving the performance of the open-weight models on CoffeeBench, such as by explicitly tracking episode state on their behalf to reduce timeouts (Section 3.2) or applying a deliberation loop to refine diagnostic hypotheses (Section 3.3).

0.24

Automated Feature Engineering, AutoML, and Decision-Focused Learning for Improved Energy Consumption Forecasting

cs.AI ·2026-09-28 ·Nasser Alkhulaifi
similarity 0.58
Abstract · PhD thesis, School of Computer Science, University of Nottingha, United Kingdom

The rising cost and demand for energy, together with environmental sustainability goals, create major challenges for energy management. Energy Consumption Forecasting (ECF) supports planning by predicting future consumption, but Machine Learning (ML) models for ECF often depend on expert-driven Feature Engineering (FE). This thesis addresses that dependence through three contributions. First, it establishes and evaluates a comprehensive FE pipeline for ECF and investigates domain-specific features. Second, it introduces AutoEnergy, a domain-tailored automated FE algorithm that generates interpretable features from timestamps and lagged consumption and integrates with AutoML for end-to-end ECF modelling. Across eighteen real-world energy datasets spanning residential, commercial, industrial, renewable, and grid domains, AutoEnergy reduces forecasting error by 19.52%-84.72% relative to baseline AutoML and established automated FE methods, while running 1.31-4.41 times faster, with gains varying by dataset. Third, AutoEnergy is integrated with Decision-Focused Learning (DFL) for a Battery Energy Storage System problem, jointly forecasting electricity prices and demand while optimising charging and discharging decisions. On a real-world UK property dataset, this approach reduces operating costs by 22.9%-56.5% compared with the same DFL models without automated FE. Overall, the results show that domain-specific automated FE can reduce reliance on manual feature design, improve forecasting accuracy, and translate predictive gains into measurable operational benefits in energy management.

0.14

Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

cs.LG eess.SP ·2026-11-13 ·Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier +2 more
publishedhot direction similarity 0.57
Abstract · 9 pages, 3 figures, 5 tables. Accepted for oral presentation at the 21st International Conference on Developments in Power System Protection…

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

0.34

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.57
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Full-Feature versus Limited-Input Machine Learning for Residential Energy Estimation: A Comparative Analysis of RECS and ResStock Under Realistic Input Constraints

cs.LG ·2026-08-10 ·Aditya Ramnarayan, Fatih Evren, Patti Gunderson, Samuel Rosenberg
code/data similarity 0.56
Abstract

Residential energy estimates are often needed before detailed envelope characteristics, equipment efficiencies, infiltration, sensor, or billing data are available. This study quantifies the trade-off between predictive accuracy and input accessibility using two nationally representative U.S. residential-energy datasets: the survey-based Residential Energy Consumption Survey (RECS) and the simulation-based ResStock dataset. Full-feature models were first used to establish dataset-specific performance benchmarks. For total-energy estimation, the models were subsequently restricted to ten low-burden variables obtainable from occupants, administrative records, or location-based weather data without an on-site energy audit. Among CatBoost, XGBoost, LightGBM, Random Forest, and Neural Networks, CatBoost consistently achieved the highest predictive performance for the full-feature analysis, reaching R2 = 0.90 for ResStock and R2 = 0.73 for RECS. When the feature set was restricted to ten homeowner-accessible inputs to simulate realistic deployment conditions, model performance converged to R2 = 0.61 for RECS and R2 = 0.62 for ResStock, showing that algorithmic complexity cannot fully compensate for missing physical and behavioral information. However, for a more homogeneous ResStock cohort consisting of single-family detached, natural-gas-heated homes in Climate Zone 6A constructed between 2000 and 2010, a reduced-input model improved accuracy to R2 = 0.85, demonstrating the value of targeted modeling for homogeneous populations. The results indicate that tree-based ensemble models can serve as high-fidelity emulators of national-scale residential energy datasets. However, careful consideration of feature availability, dataset origin (empirical vs. synthetic), and applicable use cases are also important.

0.20

A Hybrid Rule-Based and AI-Augmented Framework for Automatic Failure Recovery in DevOps Deployments

cs.SE cs.DC ·2026-09-21 ·Raju Chowdhury, Aniruddha Singh Gautam, Apurv Ghai
similarity 0.55
Abstract · This is the preprint version of a paper accepted at the ETNCC 2026 Conference. The final published version will appear in IEEE Xplore. This …

Automatic failure recovery is another difficult area of DevOps deployments due to the complexity of the system, high workload and the limitations of the traditional rules-based or manual approach. This study proposes a hybrid model integrating deterministic, rule-based recovery with the assistance of machine learning by fault prediction to automatically monitor failures, identify, classify and recover failures in real time. To test the architecture, a distributed log dataset of 100,000 records was used for models such as Decision Tree, Random Forest, Logistic Regression, LightGBM, Autoencoder with BiLSTM. The Decision Tree had a strong performance in defect identification with an F1 score of 80.8%, recall of 80.0%, precision of 81.6%, and accuracy of 89.4%. An impressive 83.3% success rate was achieved by the automated recovery measures, resulting in a 94.6% decrease in mean time to recovery (MTTR), a 95.4% reduction in downtime, and annual savings of 7,462. The combination of explainable rule-based logic and adaptive AI prediction in the framework means it is more resilient, operationally efficient, and scalable, and an effective, autonomous approach to DevOps environments evaluated under controlled experimental conditions.

0.35