CS Paper Radar

Intervention anchors and scientific verification in synthetic vascular predictive representations

Lingsen You, Yujun Guo, Xinyu Zhong, Zisu Peng, Wentong Wang, Li Shen, Junbo Ge

cs.AI ·submitted 2026-10-08 11:10 UTC · v1
unusual

Abstract

Complete orthogonal predictive coordinates do not by themselves bind a latent direction to a named intervention. We present a mathematical and synthetic audit motivated by vascular device-vessel suitcordance. Capacity-matched least-squares predictors were exactly equivalent under complete fixed output transforms, whereas an anchor-only observer recovered interpretations only within the span of known perturbation signatures. Six three-dimensional configurations across 64 seeds gave a maximum paired prediction discrepancy of 6.7e-15 but a median untransported edit error of 1.513. Coordinate transport removed that error. Noisy and weak anchors constrained calibration stability, and changing the representation basis required recalibration or verified transport. Across 256 additional fits in dimensions 3-24, prediction equivalence persisted within 4.0e-15. We then evaluated nine deliberate runnable fault classes across 64 seeds. All 576 faulty executions completed, but each violated at least one reconstruction, prediction, delivered-edit or scope contract; all 320 valid control records passed. Repeating a faulty implementation gave exact self-agreement despite error against the separately computed simulator expectation. For one omitted-direction defect, probe coverage followed its analytic law, and rank-aware abstention protected unsupported interpretations. Scalar-noise experiments exposed both missed weak faults and excessive rejection under narrow relative tolerances. These controls provide an executable separation of prediction, semantic support and scientific acceptance. They are synthetic numerical audits, not clinical validation, neural JEPA-Anything replication, agent learning or patient treatment-effect estimation.

Comment
Technical Note; 18 pages, 8 figures; reproducibility source and data archive included

Closest papers

Nearest neighbours by meaning across the whole index.

Same World, Different Knowledge: When Isolated Audits Misjudge World-Model Repairs

cs.RO ·2026-09-17 ·Rui Min, Xianyao Li, Fang Xu, Sofiane Lachab, Jing Du
similarity 0.53
Abstract · 9 pages, 3 figures, 6 tables

A repair favored under an isolated input fault can be inferior when deployed modules share the faulty information. We introduce an information-interface audit for world models, distinguishing fidelity gaps, where exact inputs become estimates, from availability gaps, where inputs are missing. Fixed-weight interventions measure prediction error, input dependence, and paired closed-loop benefit, including dependencies introduced by reconstruction. In simulated quadrotor model predictive control, coupled, opposite-sign 10% mass/thrust calibration errors reduce a physics-anchored model's success from 69% to 8%; uncertainty training restores 65%. Wind reconstruction recovers control benefit but inherits calibration dependence. For a positive calibration offset, reconstruction-only corruption favors uncertainty-trained reconstruction, whereas shared corruption favors the baseline. Acceleration diagnostics reveal compensation between reconstruction bias and nominal-model error, also observed with a disturbance observer. Repair selection therefore depends on the information paths used in deployment.

0.23

Validating LLM-Modernized Scientific Software Through Differential Fault Injection

cs.DC cs.SE ·2026-08-14 ·Evan Coleman, Yuzhong Shen, Masha Sosonkina, Peng Xu
similarity 0.52
Abstract

Large language model (LLM) agents are increasingly used to modernize the legacy Fortran underlying production scientific software, but validation of these transformations emphasizes nominal executions and may not test whether a modernization preserves the original code's response to faults, perturbations, and reduced precision. We present a differential fault-injection validation method: a harness instruments the shared self-consistent-field driver of GAMESS at twelve sites and applies identical, deterministic faults to the original and LLM-modernized implementations, isolating the converted integral kernels. Across more than 2,200 runs, transient-fault absorption costs match a contraction-based model (predicted slopes 0.74 and 1.49 iterations per bit; measured 0.82 and 1.50), persistent perturbations halve final-energy error per additional bit, and the campaigns expose phase-dependent parallel deadlocks and false convergence under reduced precision. The original and modernized kernels agree in all 200 paired injections, and a measurement-guided synchronization change composes with the modernization, matching in all 40 pairs.

0.04

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.52
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

Same Predictions, Different Harms: Causal Auditing of Patient World Models

cs.AI stat.ME ·2026-10-04 ·Yicheng Qi, Xiyi Xiong
similarity 0.52
Abstract · 35 pages, 4 figures. Includes appendices

Patient world models used for clinical trial simulation can agree on transition kernels and arm-specific risks, yet disagree on the fraction of patients harmed by switching treatment---the counterfactual quantity that matters for intervention-aware reasoning. We audit this reliability gap in a two-stage shared-response SCM: a categorical intermediate health state is followed by common terminal care. Under independent stages, the sharp harm interval has closed-form endpoints for at most three intermediate states, with an exactness boundary at four states. Declared dependence and response-mismatch budgets yield calibrated outer bounds when stage independence or complete mediation is relaxed; in a symmetric three-state model the entire sensitivity frontier is sharp, $[0,\min\{1/2,1/3+(ρ+δ)/2\}]$, and shows exactly how budgets erase the gain over endpoint-only bounds. Two eight-variable response LPs propagate interventional uncertainty for finite-sample audits. Exact witnesses verify attainability. On public clinical simulators (EpiCare; sepsis), native configurations show little resolved stage dependence and no additional joint-compatibility gain over pairwise transport---honest negative results for reliability claims. All experiments are locally reproducible; guarantees remain conditional on the stated causal model. The results provide a concrete protocol for deciding when a patient world model is safe to trust for counterfactual harm.

0.36

ScienceBuddy-PV: A Verifier-Governed Recursive Improvement Protocol for Panvascular Intervention Research

cs.AI cs.CV ·2026-10-10 ·Lingsen You, Yujun Guo, Xinyu Zhong, Zijie Feng, Wentong Wang +2 more
similarity 0.51
Abstract · 17 pages, 17 figures, 19 references. Public-data component audit; recursive improvement is specified as a protocol and not experimentally de…

ScienceBuddy-PV adapts the ScienceBuddy recursive-in-recursive design to panvascular intervention research through a structured evidence ledger, device-vessel ontology, abstention contract and retained failure bank. Recursive harness optimization and outer-loop model learning, including reinforcement learning, are specified but not executed. We audit a fixed component, rather than the complete agent system, using separate ARCADE syntax and stenosis tasks (1,000 training, 200 validation and 300 test images per task). A shared task-masked convolutional model was trained once per representation setting; its parameters and the heuristic support gate were then held fixed, with the stenosis threshold selected on validation data. On the locked test sets, syntax Dice was 0.475 (95% CI 0.459-0.490) and stenosis Dice was 0.231 (95% CI 0.214-0.249). Stenosis pixel AUROC was 0.957 and AUPRC was 0.180 at prevalence 0.00975. The gate accepted 76.7% of stenosis-frame outputs versus 100% for a score-only comparator. In a constructed mask audit, it accepted 44.3% of reference candidates and rejected 55.7%, exposing the cost of abstention. Acceptance does not establish correctness or clinical safety. This public-data component audit makes support and abstention measurable and provides a reproducible protocol for future collaborative agent studies. It does not demonstrate recursive improvement, patient-level validity or clinical device recommendations.

0.28

What Paired Evaluations Reveal under Visual Perturbations

cs.CV stat.AP ·2026-09-28 ·Yongda Wei, Chen Zhang, Yifei Wang, Xinyu Wang, Bosen Shao +2 more
theory similarity 0.51
Abstract · 53 pages, 8 figures, including appendices

Robustness evaluation must examine diverse visual perturbations, while benchmarks cover only some real-world conditions and physical testing is costly. Paired evaluations link clean and perturbed predictions for the same image, capturing changes in correctness, confidence, and acceptance beyond aggregate accuracy. We investigate how this image correspondence supports two needs in robustness evaluation: interpreting paired evaluation results and prioritizing samples for physical testing. To interpret paired evaluation results, we fix both sets of prediction records and vary their correspondence within each class. We prove that classwise correct-correct counts give the same sharp bounds on lost acceptance and mean true-class probability decrease among retained-correct inputs as any feasible five-state refinement. Distinguishing persistent from changed wrong answers can further constrain accepted-error transitions, while shared correspondence can establish policy orderings left unresolved by separate cost intervals. To prioritize samples for physical testing, we retain each image's synthetic responses and rank clean-correct images by their mean true-class probability under corruption. Across 44 classifiers, testing the highest-risk 20% finds 67% and 45% of failures under mild screen and print recaptures, versus 58% and 36% for clean confidence and 60% and 37% for an equal-size natural-transformation average. With both probability averaging and an A3Rank scoring adaptation, the tested corruption set yields higher mean failure recall than the natural-transform set; differences between scores depend on the source and budget. Together, these findings show that the value of correspondence depends on the evaluation objective: classwise counts suffice for specified reliability bounds, while image-specific synthetic responses improve the allocation of physical tests within the evaluated pool.

0.32

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.50
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39

Discover, Falsify, Revise: Auditing Input-Use Claims from Source Code to Predictive Contribution in Agent-Discovered Cell Models

cs.LG q-bio.QM ·2026-09-23 ·Mengran Li, Bo Li, Chengyang Zhang, Yang Yan, Jinfeng Xu +1 more
benchmark similarity 0.50
Abstract

AI virtual cells aim to predict cellular responses to specified interventions, yet held-out predictive performance alone does not establish use of the supplied perturbation information. This prediction-claim gap matters in agentic model discovery, where language-model agents generate and revise predictors using score-based feedback. We introduce CELLAUDIT, which audits input-use claims by asking whether an input can enter the cited computation, whether fitted predictions depend on it, and whether that dependence improves prediction of observed response. On a paired morphology-transcriptomics perturbation benchmark (BBBC047), an agent-selected predictor attains a mean held-out Global Pearson correlation coefficient (PCC) of 0.3153 but remains invariant to compound replacement; a control-profile-only predictor reaches 0.3142. Source inspection identifies a compound-query pathway blocked by singleton key-value attention, and the invariance persists after refitting with disjoint control wells. In a stratified audit of 48 candidates across two linked tasks, 47 change predictions under compound replacement on both held-out folds, but only 20 show target-loss gains with intervals above zero on both folds. On BBBC047, falsification-guided revisions recover positive mean compound contributions while retaining gains over the control-profile-only baseline. In matched sci-Plex searches, audit-enriched feedback yields higher held-out performance and larger mean compound and dose contributions across five trajectories, although paired intervals span zero. Refitting fixed designs on an independently acquired cohort shows predictive generalization need not imply generalization of input-use claims: dose contribution persists, whereas support for compound identity does not. CELLAUDIT adds a falsification layer to agentic model discovery, moving from generate-score-revise toward discover-falsify-revise.

0.19