CS Paper Radar

FOCUS: A Subspecialty Foundation Model for Intraoperative Central Nervous System Pathology

Xing Liu, Yifan Guo, Hongtai Lv, Lei Lou, Yuyi Tan, Jiang Du, Xijia Zhang, Ming Zhang, Chao Pang, Minglei Li, Wei Liu, Xiaobo Zhu, Song Zhang, Rong Yu, Hanlin Shu, Wenzhuo Xu, Tao Jiang, Cheng Lu, Jie Tian, Qing Chang, Zhenyu Liu

cs.CV ·submitted 2026-10-12 14:59 UTC · v2
unusual

Abstract

Intraoperative frozen-section diagnosis of central nervous system (CNS) lesions guides surgical decisions but is challenged by artefacts, diagnostic complexity and time constraints. Most pathology foundation models have limited exposure to CNS frozen tissue. Here we present FOCUS, a subspecialty foundation model pretrained on 27,930 frozen-section whole-slide images enriched for CNS tissue. FOCUS ranked first across all 11 diagnostic and 12 biomarker-prediction tasks in the internal test cohort, achieving mean AUCs of 0.969 and 0.877, respectively. This advantage was retained in the temporal and external test cohorts. We further organized a WHO-aligned diagnostic hierarchy, where FOCUS also outperformed comparator models. In a reader study, FOCUS assistance enabled junior readers to approach or exceed unassisted senior readers in hierarchical diagnostic accuracy and granularity. More importantly, FOCUS assistance enabled readers to correctly identify a mean of 63.0% of initially missed lymphoma cases (73.2% among junior readers), potentially avoiding unnecessary extensive resection. These findings highlight the potential of FOCUS to provide clinically actionable support for intraoperative CNS pathology and inform surgical decisions.

Closest papers

Nearest neighbours by meaning across the whole index.

A Vision-Language Foundation Model for Precise and Comprehensive Brain Tumor Diagnosis from Preoperative Multimodal Data

cs.CV cs.AI ·2026-09-15 ·Yinong Wang, Jianwen Chen, Zhou Chen, Shuwen Kuang, Haoning Jiang +26 more
code/data similarity 0.57
Abstract · 94 pages, 22 Figures, supplement files, Project page link: https://hku-healthai.github.io/brainvlm_project.github.io/

We developed BrainVLM to classify all 12 World Health Organization (WHO) 2021 brain tumor types. BrainVLM integrates an uncertainty quantification strategy to indicate prediction reliability and a module for generating radiology reports to elucidate the clinical rationale. BrainVLM was trained on multi-modal data (MRI scans, demographics, and radiology reports) from 40,043 individuals. It was validated on 5,211 patients with pathologically confirmed brain tumors, including 3,877 held-out patients from the primary hospital and 1,334 patients from 11 independent hospitals. We further conducted two proof-of-concept studies to validate its clinical utility in AI-clinician workflows: 1) a blinded multireader study where 12 neuroradiologists across varying experience levels interpreted 248 retrospective cases with or without AI assistance, and 2) a real-world prospective study in which 1,009 patients were independently and blindly assessed by BrainVLM and radiologists before surgery. Additionally, we demonstrated BrainVLM's utility in preoperative molecular subgroup prediction for adult-type diffuse gliomas, using a multi-center cohort of 632 patients. In primary evaluation, BrainVLM achieved an area under the curve (macro-AUC) of 0.85 (95% CI: 0.84-0.86), and an F1 score of 0.82 (95% CI: 0.81-0.83), surpassing neuroradiologists (F1 = 0.80 (95% CI: 0.79-0.81)). In external validation across 11 centers, BrainVLM achieved an AUC = 0.80 (95% CI: 0.79-0.82) and F1 = 0.75 (95% CI: 0.73-0.78), compared with F1 = 0.71 (95% CI: 0.69-0.73) for neuroradiologists. In prospective real-world evaluation, BrainVLM maintained performance comparable to neuroradiologists. The BrainVLM project page is available at https://hku-healthai.github.io/brainvlm_project.github.io/.

0.35

Seeing Beyond the Lesion: Disease Recognition from Reactive CNS Tissue

eess.IV cs.CVq-bio.TO ·2026-09-02 ·Jan Schnorrenberg, Jan Ernsting, Enrico Küllenberg, Tim Hahn, Benjamin Risse +1 more
benchmark similarity 0.56
Abstract

Sampling error yields exclusively reactive, non-lesional brain parenchyma in a significant proportion of intracranial biopsies, leaving the underlying disease undiagnosed. We benchmark four pathology foundation models (UNI2-h, Virchow2, Prov-GigaPath, H-optimus-0) as frozen patch encoders within a shared attention-based multiple-instance learning framework using 245 whole-slide images from 186 patients with confirmed downstream diagnoses. We first show that coarse disease-category prediction can be reproduced largely from slide size alone. After restricting classification to three finer diagnostic distinctions within common tissue categories, this confound no longer explains performance, yet disease labels remain predictable above chance under permutation testing (p $\le 10^{-4}$ throughout). Surprisingly, performance is statistically indistinguishable across all foundation-model encoders, suggesting that recovering these weak morphological signatures is not limited by current patch representations. Signed instance-contribution maps and expert review further test whether predictive evidence localizes to reactive parenchyma rather than sampling-induced bias like blood introduced during tissue sampling. These results position acquisition-shortcut auditing via a provenance-only baseline as a necessary control in computational-pathology benchmarks, and show, once that confound is removed, that weakly supervised models still recover disease signal from tissue conventionally regarded as non-diagnostic.

0.23

What Language Adds, and at What Cost: Four Controlled Probes of Pathology Vision-Language Models

cs.CV q-bio.QM ·2026-10-19 ·Wenhao Zhang, Zhongliang Zhou, Yi Ping, Zirui Wang, Sheng Li
similarity 0.55
Abstract

Vision--language models (VLMs) promise to make computational pathology queryable and able to draft reports, but how much language adds beyond the vision backbone is unclear, because almost every system is evaluated by its developers on test sets of their own choosing. We grade published evidence by how it was produced and test four claims with controlled probes that reuse released checkpoints and public data, varying one input at a time. Report text adds prognostic signal: adding a frozen embedding of the stage-redacted report to a slide embedding raises the pooled C-index by 0.019 for progression-free interval and by 0.016 for overall survival across 1{,}633 TCGA patients, and restoring the stage statement adds nothing. Prompts add no measurable accuracy at inference: with features and pooling fixed, zero-shot classification is statistically indistinguishable from a supervised linear probe for lung and renal cancer subtyping. Slide-level question answering is barely grounded: SlideChat answers 74.82\% of SlideBench-VQA(TCGA) items correctly with the slide and 74.41\% without it, whereas its language backbone alone reaches 43.52\%. Paraphrasing leaves accuracy unchanged but flips 8--23\% of answers. Self-reported gains from agentic navigation and few-shot language priors cannot yet be attributed to language. Language thus adds real but narrow value, and we propose minimum controls that would expose these failure modes in future evaluations.

0.18

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

cs.CV cs.HCeess.IVeess.SP ·2026-10-30 ·Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco +2 more
similarity 0.55
Abstract · 20 pages on main manuscripts (3 tables + 4 figures), 14 pages supplementary (10 tables + 8 figures)

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

0.17

A Comparison of Whole Slide Image Analysis and Diagnostic Field Selection in Pathology AI under Finite Resources

eess.IV q-bio.QM ·2026-08-11 ·Tatsuaki Tsuruyama
similarity 0.55
Abstract

An important question in pathology AI is how to allocate limited analytical resources between broad coverage of a whole slide image (WSI) and detailed analysis of selected regions. We compared a minimal WSI-AI model designed for broad search with Diagnostic Field Selection AI (DFS-AI), which uses a coarse overview to select diagnostically relevant fields for detailed analysis. Three minimal models introduced localization information, contextual discrimination, and spatial structure in sequence. In Model I, WSI-AI was favored when coarse localization was uninformative or costly. When coarse observation provided useful ranking information, DFS-AI was favored over an intermediate range of resources; WSI-AI again became preferable when resources allowed nearly complete fine observation. In Model II, background heterogeneity generated distractors. In a WSI control given the same local context as DFS-AI, most of the original DFS advantage was explained by local background correction, while coarse candidate selection provided a smaller additional benefit. In Model III, larger contiguous lesions were easier for WSI-AI to discover but more difficult to characterize completely with a finite budget for fine observation. The DFS advantage for complete characterization persisted when the comparator used the same field sized unit of fine analysis and when success was defined symmetrically as 100%, 90%, or 80% lesion unit coverage. Together, the models support a framework in which the preferred strategy changes with available resources and depends on the information available for selection, its acquisition cost, lesion structure, and the diagnostic endpoint. This framework clarifies when limited pathology AI resources should be devoted to broad WSI coverage and when they should be concentrated on selected Diagnostic Fields.

0.04

From Few-Shot Segmentation to Clinician-in-the-Loop Medical Image Analysis

cs.CV ·2026-09-09 ·Yazhou Zhu
similarity 0.55
Abstract · 25 pages, 3 figures, 5 tables. Perspective article

Few-shot medical image segmentation (FSMIS) seeks to delineate unseen structures from a small support set, but its standard formulation fixes task-defining evidence before inference. This assumption is fragile under acquisition shift, atypical pathology, ambiguous boundaries, and poor image quality. Adding clinician interaction and rapid adaptation is not sufficient: the binding constraint is deciding when asking or changing is warranted. We therefore reframe FSMIS as a three-layer sequential decision problem. First, decidable self-assessment separates errors that a bounded intervention can repair from those that no admissible intervention can reach. We formalize this distinction through a correctable set defined by the update operator and remaining interaction budget. Second, selective interaction allocates a distinct expert-attention budget by response-conditioned net expected value of information, yielding explicit accept, query, and defer actions. Third, bounded adaptation emphasizes reversibility and independent safety reassessment rather than speed. A complementary cross-case memory stores reproducible correction priors over failure modes instead of disease-specific mask priors. This structure links sparse support representation, cross-domain robustness, multi-level risk estimation, clinician feedback, and governed experience transfer. We state six hypotheses with an explicit dependency order and propose a minimal pilot that can falsify the foundational self-assessment claim before a clinician study. The central claim is not that interaction resolves domain shift, but that scarce expert attention should be used only when a bounded intervention is expected to reach a clinically better outcome.

0.29

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.54
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.54
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19