CS Paper Radar

Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning

Kritsanavis Chongsrid, Vich Yindeedej, Supaporn Konmun, Xulei Yang, Si Yong Yeo

cs.CV q-bio.QM ·submitted 2026-10-14 12:12 UTC · v1
unusual

Abstract

Catheter obstruction is the commonest cause of shunt failure; freehand insertion at Keen's point leaves the tip free in cerebrospinal fluid in only one case in ten. We built a digital twin that reconstructs skull, scalp, ear and ventricles from preoperative CT by deterministic geometry, searches every entry around Keen's point for the perpendicular trajectory with the longest intraventricular length under safety constraints, and returns the plan as two ruler measurements from the ear and two depths. Executed freehand in 11 consecutive adults (IDEAL Stage 2a), it achieved Hayhurst Grade 1 placement in 10 of 11 against 22 of 213 historically (p = 9 x 10^-9), median entry and angular deviations 2.5 mm and 5.9 degrees, 1.4 cm more intraventricular catheter than Keen's point, and no intraoperative complication. The technique was unchanged; the gain came from choosing entry and depth per patient. Whether it lowers revision is the next stage's hypothesis.

Comment
29 pages, 8 figures, 2 tables; includes Supplementary Information

Closest papers

Nearest neighbours by meaning across the whole index.

DuoPIC: Uncertainty-Aware Voxel-Level Digital Twins of Cerebral Perfusion with Transport PDEs in Acute Stroke

cs.CV ·2026-10-20 ·Anh Duong Tran, Quang-Anh N. D., Toan Sy Pham, Trang H. Hoang, Minh N. Do +2 more
code/data similarity 0.54
Abstract

Digital twins of cerebral perfusion relate tracer dynamics to cerebral blood flow (CBF), blood volume (CBV) and mean transit time (MTT), but must be data-driven, physically consistent and uncertainty-aware. We introduce DuoPIC, a digital twin that needs no reference maps, in which a Windkessel flow model drives a tracer transport partial differential equation (PDE). A population-level neural closure divides each region into fast and slow pathways with tracer mass and MTT conserved by construction, and a tempered posterior quantifies the uncertainty of every estimate. Its voxel maps set the state of the art for lesion detection on ISLES'17 MR (AUC 0.745) and ISLES'24 CT (0.743). On held-out patients, the neural PDE reduced the compartment's reconstruction error by 19% and lifted 95% MTT interval coverage from 88% to 94%. Code: https://github.com/detinatran/duopic

0.36

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

cs.AI physics.med-ph ·2026-09-21 ·Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li +4 more
similarity 0.50
Abstract

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.

0.43

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

cs.AI physics.med-ph ·2026-09-30 ·Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen +10 more
similarity 0.50
Abstract

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.

0.06

Estimates of neural health using cochlear implant digital twins correlate with speech recognition

eess.SP ·2026-09-29 ·Erin L. Bratu, Andrea J. DeFreese, Katelyn A. Berg, Margaret Wilson, Aaron C. Moberly +2 more
similarity 0.48
Abstract

The cochlear implant is a neural prosthetic that uses an array of electrodes to directly stimulate auditory nerve fibers with electrical impulses. One factor that is known to impact outcomes is the quality of the electro-neural interface. In this work, we propose a pipeline that permits creating accurate and patient-specific digital twins that model the cochlear implant electro-neural interface. We leverage medical images and electrophysiological measurements from the patient's device for digital twin construction. We validate our digital twins by comparing predictions of neural response measurements to clinical measurements and speech recognition outcomes. Neural health estimated by the digital twin correlates strongly with word recognition rates (R=0.75, p<1e-5) in an analysis of 29 cases and sentence in noise recognition rates (R=0.78, p<1e-4) in an analysis of 21 cases. We also report preliminary findings with digital twin-based patient remapping with 6 subjects, where word recognition rates improved on average by 10 percentage points. These digital twins have the potential to provide clinicians with an unprecedented window into the electro-neural interface for individual cochlear implant recipients, which could lead to improved hearing outcomes when used as a foundation for program customization.

0.24

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
similarity 0.47
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.25

Risk Control Certifies Rates, Not Magnitudes: An Audit of Selective Fetal Biometry

cs.AI cs.CV ·2026-11-04 ·Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao
theory similarity 0.46
Abstract · 10 pages, 2 figures, 3 tables

Prenatal ultrasound biometry must return a head circumference (HC) and refuse when the image cannot support one. Selective prediction trades coverage against error, but its finite-sample guarantees bound the rate of gross errors, not their magnitude. We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each. Calibrating the contour-completeness threshold by exact Clopper-Pearson risk control returns a certificate indistinguishable from a hand-set floor, yet the pipeline still emits a 271.3 mm error: a small, geometrically complete ring fitted to an image whose true HC is 324.6 mm. The accepted candidate scores 0.94 completeness, so the score cannot see the failure, and one outlier among $\approx 150$ answers leaves the certified risk bound ($α= 0.10$) intact. A second, untouched split reproduces the mechanism on a different image (233.3 mm). Constraining the admissibility region---the anatomical range in which the measurand is defined---removes the family instead: raising the lower bound from 50 to 55 mm costs 0.4 coverage points and cuts the worst-case error on both splits to 11.4 and 11.1 mm, whereas suppressing it through the completeness threshold costs 19.0 and 12.1 points. At an anatomically defined 70 mm the frozen tests give 1.91 and 1.81 mm MAE.

0.27

Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates

cs.AI cs.LG ·2026-09-14 ·Ali Nourbakhsh, Mohammad Reza Niroomand, Erfan Nourbakhsh
code/data similarity 0.45
Abstract · 8 pages, 6 figures, Under review at ICBME 2026

Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion

0.43

ICare-DT: a digital twin for continuous forecasting of intensive care patients

cs.LG cs.AI ·2026-11-06 ·Yanke Li, Yahang Qi, Yumi Kim, Diego Paez-Granados
benchmark similarity 0.45
Abstract

Digital twins of intensive care patients should update forecasts from new data and predict treatment responses, but few studies test whether routine records support either. We propose ICare-DT, a Transformer-based twin that updates a latent patient state hourly from new measurements without retraining. We trained it on 140,473 eICU-CRD stays to forecast vital signs crossing their training-set means. On test data, later forecasts beat the twin's own hour-6 forecasts of the same windows in all 12 settings (+0.073 to +0.153 AUROC). On validation data, controls that withheld or swapped the new hours traced the gain to the patient's own measurements. Without refitting, the model kept its gain on a second database (8 of 9 settings, +0.025 to +0.114 AUROC) in a prespecified evaluation of the previously analyzed MIMIC-IV test split. Refitted within MIMIC-IV, a twin state fine-tuned on clinical endpoints gave gradient boosting a significant gain for acute kidney injury (+0.0035 AUROC; hypotension +0.0010, not significant). To test response prediction, we built a benchmark that replaces the treatments in real records with simulated doses and injects responses of known size, visible only at measurement times. Ridge models supervised with injected effects recovered them from real records only through frequently measured variables (heart rate) read at their measurement times. We asked standard learners to predict these effects for a dosing regime no patient had received. No standard learner outperformed predicting zero effect at an out-of-support query. When told how the simulated responses were generated, a separate learner recovered the effects from the same records without seeing their true values (R2 0.30 to 0.40 at one effect size). Routine records support forecasts that improve with each patient's new data, and our benchmark is a testbed for models that learn how responses are generated.

0.25