CS Paper Radar

Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates

Ali Nourbakhsh, Mohammad Reza Niroomand, Erfan Nourbakhsh

cs.AI cs.LG ·submitted 2026-09-14 20:37 UTC · v1
code/data

Abstract

Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion

Comment
8 pages, 6 figures, Under review at ICBME 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.58
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

Agentic AI Reasoning and Learned Sampling for Task-Aware Projection Selection in Sparse-View CT: Predicting Hemodynamics

cs.AI physics.flu-dyn ·2026-10-28 ·Mahmoud Elhadidy, Roshan M. D'Souza, Amirhossein Arzani
similarity 0.58
Abstract

Sparse-view computed tomography (CT) reduces the number of acquired projections, but conventional sampling strategies are designed primarily for image reconstruction rather than for downstream physical inference. Here, we investigate optimal task-aware projection selection for directly predicting hemodynamics from sparse CT angiography (CTA) measurements. Using computational fluid dynamics simulations of intracranial aneurysms, we generate synthetic fan-beam CTA projections and train a Fourier neural operator (FNO) to predict two targets: the spatially resolved time-averaged wall shear stress (TAWSS) field and the spatially averaged TAWSS. The FNO was coupled with optimal input selection for simultaneous optimal sampling and training. Our goal was to investigate if agentic AI could discover optimal sampling strategies that outperform current methods. We compared fixed uniform and golden-angle sampling with three task-aware optimal selection strategies: Gumbel-Softmax, a Soft top-K method, and an agentic AI selector. The methods were compared at different view selection budgets. A detailed analysis of the AI agent was performed to understand its reasoning and performance. For spatially resolved TAWSS, Agentic and Soft top-K achieve the lowest mean errors (Agentic performs slightly better) and substantially outperform fixed sampling under extreme sparsity. For spatially averaged TAWSS, optimized selection becomes important at extremely sparse acquisitions. Analysis of the selected masks reveals multiple distinct subsets concentrated around informative regions. Moreover, masks optimized for hemodynamic prediction yield poor image reconstructions, showing that task-optimal acquisition differs fundamentally from reconstruction-optimal acquisition. This work suggests the possibility of designing sparse acquisitions directly around downstream physical quantities.

0.27

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.57
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.53

Anatomy-Informed Neural Networks: Encoding Anatomic Priors in Loss and Architecture, with an SE(3) Formulation of Guidewire-Induced Aortoiliac Deformation

cs.AI cs.CVcs.RO ·2026-08-21 ·David P. Stonko
similarity 0.56
Abstract · 42 pages, 10 figures, 4 tables

Deep-learning models of anatomy can be numerically plausible yet anatomically impossible, and they generalize poorly when data are scarce. We introduce Anatomy-Informed Neural Networks (AINN), in which soft anatomic priors enter as penalty terms in the loss (e.g., a branching penalty that treats a renal transplant artery off the iliac instead of the aorta as unexpected rather than impossible), in direct analogy to a physics-informed neural network, and hard anatomic priors (e.g., continuity of the vessel) are built into the architecture and state representation, making such invalid predictions impossible by construction wherever the prior admits architectural enforcement. We develop it on a clinical test case with limited data: how the aortoiliac tree deforms when a stiff wire is introduced endoluminally. This is important to contemporary aortic surgery and will matter to autonomous endovascular navigation. We lift the vessel centerline and the wire path from R^3 to curves of frames in the Lie group SE(3), and couple a Cosserat-rod wire to a tortuosity-modulated, anatomically anchored vessel through a unilateral lumen-contact inequality. The prediction is a constrained minimizer of the coupled elastic energy, with contact forces as its Lagrange multipliers. Supervision is a Wasserstein-2 optimal-transport loss between the predicted projection through the C-arm geometry and the observed angiogram, so a 2D angiogram can train a 3D prediction. The kinematics, loss and projection are verified against known ground truth; the mechanics solver only against its own optimality conditions, and predicted displacement is not yet mesh-converged. Here, no network is trained. Future work will transfer this in silico model to real CT scans and test whether it improves predictive accuracy and reduces the training data required.

0.31

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

cs.CV ·2026-09-03 ·Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus Hüllebrand, Sebastian Schmitter +11 more
code/data similarity 0.56
Abstract · Submitted to Journal of Cardiovascular Magnetic Resonance

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

0.45

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.56
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.54
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

DuoPIC: Uncertainty-Aware Voxel-Level Digital Twins of Cerebral Perfusion with Transport PDEs in Acute Stroke

cs.CV ·2026-10-20 ·Anh Duong Tran, Quang-Anh N. D., Toan Sy Pham, Trang H. Hoang, Minh N. Do +2 more
code/data similarity 0.54
Abstract

Digital twins of cerebral perfusion relate tracer dynamics to cerebral blood flow (CBF), blood volume (CBV) and mean transit time (MTT), but must be data-driven, physically consistent and uncertainty-aware. We introduce DuoPIC, a digital twin that needs no reference maps, in which a Windkessel flow model drives a tracer transport partial differential equation (PDE). A population-level neural closure divides each region into fast and slow pathways with tracer mass and MTT conserved by construction, and a tempered posterior quantifies the uncertainty of every estimate. Its voxel maps set the state of the art for lesion detection on ISLES'17 MR (AUC 0.745) and ISLES'24 CT (0.743). On held-out patients, the neural PDE reduced the compartment's reconstruction error by 19% and lifted 95% MTT interval coverage from 88% to 94%. Code: https://github.com/detinatran/duopic

0.36