CS Paper Radar

Persistent Profile-Guided Reset-Free Recovery Improves Final Gait Selection after Irreversible Leg Damage

Minjoong Kim

cs.RO ·submitted 2026-10-14 19:26 UTC · v1

Abstract

Damage-recovery algorithms often rank gaits from short trials, yet a gait that performs well briefly may not remain effective during continued execution. In reset-free recovery, each trial also changes the physical state inherited by the next. We introduce persistent profile-guided reset-free recovery (PGRR), which predicts multiple outcomes over repeated gait execution and uses conservative uncertainty-aware estimates to guide short online probes without resetting the robot. Across 108 matched MuJoCo tasks spanning leg amputation, distal fracture, and joint lock, PGRR improves final quality by 0.106 and slot-averaged recovery quality (SRQ) by 0.044 relative to an IT&E-inspired Gaussian-process baseline, while reducing low-quality failures by 27.8 percentage points. Final-quality gains occur in all three damage classes. Against no adaptation, PGRR also improves final quality and reduces low-quality failures, whereas the aggregate SRQ difference is inconclusive. Development ablations identify conservative uncertainty handling as the clearest supported contributor to the observed gains. These results show that PGRR can identify stronger post-damage gaits under continuous physical state and that final-gait quality and recovery-summary performance provide complementary evidence for evaluating reset-free recovery.

Comment
7 pages, 4 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

When Black-Box Robot Policies Fail: Online Sensor Diagnosis and Repair with a Transparent Surrogate

cs.RO ·2026-10-27 ·Marc Ziegler, Batu Özen, Sami Mentes, Thomas Waschulzik, Alois Knoll
similarity 0.65
Abstract · Accepted at the Conference on Robot Learning 2026 Workshop on the Science of Physical AI Safety (SPAIS)

Robot foundation models may generalize across tasks and embodiments, but their actions still depend on sensors that can fail. When the policy is frozen or inaccessible, can an external monitor diagnose and repair corrupted inputs without access to its internals? We test a structured surrogate that separates periodic gait from sensor-dependent corrections to guide input repair around a frozen locomotion policy. On simulated Go2, offline diagnosis raises walking success from 259/640 to 429/640 episodes; online repair reaches 382/640, with no triggers in 64 held-out fault-free episodes. A matched boosted-tree surrogate predicts clean actions similarly well but yields no detected repair improvement over no repair. Separate fits improve walking on Go1 and ANYmal C, although phase-aware gradients perform better. Evidence remains limited to one policy and a partly screened simulated fault suite; robot foundation model and hardware validation remain open.

0.22

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.63
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

Nine Trials to Recover: A Reproducible Benchmark for Repertoire-Free Soft-Robot Damage Adaptation

cs.RO eess.SY ·2026-10-06 ·Siyuan Zhang
benchmark similarity 0.62
Abstract · 8 pages, 7 figures, 3 tables

We present a repertoire-free benchmark for soft-robot damage recovery under nine online trials. The protocol pairs damage masks within each morphology, retains a measured nominal fallback, and separates method development from evaluation on new bodies. A Gaussian-process expected-improvement (GP-EI) reference controller adapts actuator phases using three initialization probes and six feedback-selected rollouts. Across two disjoint 75-body cohorts, it outperforms random search, Sobol, CEM, and CMA-ES under equal budgets. GP-EI improves the worst-mask gain on 69/75 confirmation bodies and exceeds these four baselines by 0.235-0.310 mean worst-mask reward. A TuRBO-style local GP is the closest comparator; the paired confidence interval includes zero. Post-confirmation fixed-controller replay finds 5.06 voxel widths of mean recovery together with a 0.0031 increase in worst-mask p99 geometric edge strain; a strict no-added-demand deployment gate retains 48.7% of mean gain. In a frozen development stress test that physically removes 10% of occupied voxels, GP-EI improves 71/75 bodies and exceeds official BoTorch TuRBO by 0.356 mean worst-mask gain. Together, the replayable controllers, body-level inference, and frozen-cohort evaluation provide a reference for measuring the added value of learned damage priors and future adaptation methods.

0.25

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
similarity 0.58
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

cs.CV cs.AI ·2026-08-28 ·Mohammad Arif Ul Alam
similarity 0.58
Abstract

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths (R-square = 0.92 in development validation and approximately 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only +/-5% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.

0.24

REBOOT: From Failure to Recovery - A Dataset and Benchmark for Precision Assembly

cs.RO ·2026-09-18 ·Nana Yaw Owusu Ofori-Ampofo, Samira Ebrahimi Kahou, Joseph Thekinen
benchmark similarity 0.58
Abstract · Project website: https://nanayawoa.github.io/REBOOT

Robot learning policies fail in characteristic ways: they stall in uncertain states, drift during contact-rich alignment, and miss targets by millimetres in precision tasks. Yet training datasets consist largely of successful demonstrations, while real-world benchmarks often reduce performance to binary success. This limits both supervision for recovery and analysis of where failures occur. We introduce REBOOT (Recovery Episode Benchmark for Off-nominal Trajectories), the first robot manipulation benchmark designed around failure as a first-class signal. REBOOT contains 2,160 demonstrations across 18 precision assembly tasks, each decomposed into five shared phases: Align(pick), Engage(pick), Transport, Align(place), and Engage(place), enabling phase-level evaluation beyond terminal success. Failures are introduced across phases and paired with expert recovery trajectories that return the system to a valid continuation state. Tasks are annotated with rotational symmetry, engagement-clearance precision tier, and assembly direction through matched install-remove pairs. Failure episodes are labeled by phase and categorical failure mode, enabling attribution to kinematic stage and tolerance violation. Data includes synchronized RGB-D observations from four viewpoints and grounded natural-language descriptions of phase-level success and failure conditions. Half the dataset contains expert demonstrations; the other half contains recovery demonstrations sampled to reflect failures observed in imitation-learned policy rollouts. We benchmark action-chunked transformer, diffusion, and $π_0$-FAST policies using phase-level completion rates, revealing model-specific failure points hidden by binary evaluation. Dataset and code: https://nanayawoa.github.io/REBOOT

0.50

SG-CPG: Severity-Gated Central Pattern Generators for Adaptive Quadruped Locomotion under Continuous Actuator Degradation

cs.RO eess.SY ·2026-09-22 ·Adarsh Kumar Kosta, Kaushik Roy
similarity 0.57
Abstract · 8 pages, 5 figures, 5 tables

An animal with a weakened limb does not necessarily switch its gait, instead it unloads the affected limb, re-coordinates the remaining limbs, and scales its response with injury severity. This graded adaptation allows locomotion to persist despite partial loss of limb strength, rather than requiring a discrete transition between healthy and failed. Inspired by this behavior, we propose SG-CPG, a central pattern generator (CPG) for quadruped locomotion under continuous actuator degradation. SG-CPG preserves a frozen healthy CPG policy and introduces two severity-driven gates: a residual gate that re-coordinates all four legs and an amplitude gate that progressively shortens the weakened leg's stride as degradation increases. We emulate progressive degradation through two mechanisms: lowering the joint torque ceiling (ceiling mechanism) and scaling its low-level controller gains (gain mechanism), representing distinct forms of actuator weakening. Our simulations on a Unitree Go2 show that SG-CPG maintains a trot gait with 100% survival across an omnidirectional command schedule under 95% joint strength loss while tracking commands within 8%. Under a lowered torque ceiling, removing either severity path, the residual's severity observation or the amplitude gate, raises clipping at the weakened joint from 4.4% to 13.6% and 26.3% of steps at an 80% loss. On a real Go2, SG-CPG survives 28 of 29 forward and turning trials with up to 93% calf torque degradation. These results show that severity-gated adaptation can extend a healthy locomotion policy to progressive actuator degradation without treating the fault as a discrete failure.

0.17

OmniMimic: Dynamics-completed Motion Augmentation for Multi-style Omnidirectional Quadruped Locomotion

cs.RO cs.CVeess.IV ·2026-09-17 ·Sheng Wu, Guoqiang Zhao, Zhe Yang, Fei Teng, Zhikun Zhou +5 more
code/data similarity 0.57
Abstract · The project page is at https://OmniMimic.github.io

Animal demonstrations provide quadruped robots with natural and distinctive gait styles that are difficult to specify through hand-crafted rewards. However, their narrow directional coverage leaves little style-consistent supervision for backward, lateral, and turning commands. We present OmniMimic, a training framework that turns directionally limited animal demonstrations into a single multi-gait policy over target per-axis velocity ranges. OmniMimic first combines temporal reversal, constrained dynamics completion, and sagittal reflection to construct robot-specific kinematic and physical supervision beyond the observed directions. It then expands commands progressively from the demonstrated velocity distribution toward the target per-axis bounds, and uses a shared actor with soft-gated, gait-specialized residual experts to balance reusable locomotion skills with gait-specific corrections. Across four gaits in simulation, OmniMimic reduces mean foot-position RMSE at forward and backward reference velocities by 12.9% and velocity-tracking RMSE on a uniform Cartesian command grid by 63.1%, compared with the matched APEX baseline. The project page is at https://OmniMimic.github.io.

0.35