CS Paper Radar

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions

Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza

eess.IV ·submitted 2026-10-15 02:17 UTC · v1

Abstract

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

Comment
8 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Evidence Field: Adaptive Covering Programs for Medical Imaging

eess.IV cs.AIcs.CVcs.LG ·2026-10-17 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
similarity 0.71
Abstract · 9 pages, 5 figures

Medical image classifiers typically return predictions without a native contract for independently reconstructing their spatial decision computation. Evidence Field is a trainable spatial-program architecture that jointly produces class scores, selected covering programs and signed evidence. Its encoder combines absolute and image-relative response fields with associative spatial moments and learned characteristic sums. A typed classifier scores individual regions and parent-conditioned multiplicative groups; a covering recursion selects scale, partition and composition. We establish exact one-fold coverage, optimality within the registered grammar, a bound relating smooth training to hard inference, signed-score conservation and class-centred offset invariance. Direct contractions and their adjoint specify arithmetic and storage scaling on two- and three-dimensional grids. Native output records bind inputs, parameters, supports, types and contextual dependencies to individual and ensemble predictions. In a separately reported histopathology application, patient-separated training and evaluation across held-out centres provide empirical evidence for the architecture. Trained mechanism and corrected-loss comparisons distinguish predictive effects from implementation correctness; independent readers reconstruct descriptors, routes, scores and probability mixtures. The principal contribution is a coupled representation, decision and evidence architecture whose selected computation can be reproduced independently.

0.37

With foundation-model features, aggregator complexity does not improve cross-hospital discrimination in gastric whole-slide image classification

eess.IV cs.AIcs.CV ·2026-10-30 ·Nheng Vanchhay, Ali Hussain, Khan Ziaullah, Moon-Il Joo, Md Ariful Islam Mozumder +12 more
similarity 0.61
Abstract

Whole-slide image classifiers are usually developed within one hospital and often go untested at unseen hospitals. We assembled 5,036 haematoxylin-and-eosin-stained gastric slides from five Korean hospitals, scanned at 20x and 40x, and compared multiple-instance learning aggregators under leave-one-hospital-out validation on frozen pathology foundation-model features. A hierarchical patch-region-slide graph aggregator (CHIME-MIL) with site alignment and two-scale fusion reached a mean area under the receiver operating characteristic curve (AUC) of 0.837, above six conventional attention and transformer aggregators trained without these steps. Under a matched recipe it did not exceed attention-based pooling, and global max pooling given the same alignment and fusion was better (AUC 0.855, P = 0.0002). The alignment, which subtracts each hospital's mean feature vector without labels, onboarded a new hospital from ten unlabelled slides and cost 0.002 AUC without held-out-hospital data, but its accuracy gains were small and inconsistent. The model had low top-label calibration error (0.053) but under-confident malignancy probabilities, and removing its most-attended patches lowered the malignancy probability far more than removing random patches. With these features, more complex aggregators did not improve discrimination; what a deployable system adds is label-free onboarding, calibration checks and auditable evidence.

0.13

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

cs.AI cs.CV ·2026-10-30 ·Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim
top venuecode/data similarity 0.61
Abstract · Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 39 pages, 3 figures. Code and data: https://github.com/eunseobchoi/ReuScope

We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

0.55

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.61
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.61
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.18

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark similarity 0.61
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.61
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation

cs.CV ·2026-11-09 ·Akwasi Asare
similarity 0.61
Abstract · Under review at Scientific Report Journal, Springer

Deep learning models for brain tumor MRI classification are usually compared by accuracy alone, on public datasets whose independence is rarely checked. We benchmarked six architectures: two convolutional networks (EfficientNetV2-M and ConvNeXt-V2-Tiny), two vision transformers (Swin-V2-S and ViT-L/16), and two foundation models (DINOv2-L and MedSigLIP-448), for four-class classification of 7,216 public MRI images. We assessed accuracy, calibration, explainability, ensembles, and decision curves, with every fitted quantity estimated on validation data only. Pixel-verified duplicate screening showed that 36% of the test images had a near-duplicate in the training data. Test accuracy ranged from 94.5% to 95.6%, with no pairwise difference after Holm correction, and fell to 90.3% to 91.7% on the 773 test images free of duplicates and shared patients. Ensembles did not outperform the best single model. Attribution maps passed a model-randomization test but localized expert-annotated tumors poorly. On 1,675 external BDNeuro-MRI images that did not duplicate the training data, accuracy ranged from 77.6% (MedSigLIP-448) to 95.0% (ViT-L/16), and 12 of 15 pairwise differences were significant. Internal accuracy on this public collection therefore did not distinguish the architectures, whereas the duplicate-filtered external test did.

0.16