CS Paper Radar

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim

cs.AI cs.CV ·submitted 2026-10-30 14:51 UTC · v1
top venuecode/data

Abstract

We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

Comment
Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 39 pages, 3 figures. Code and data: https://github.com/eunseobchoi/ReuScope

Closest papers

Nearest neighbours by meaning across the whole index.

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.63
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

OpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation

cs.CV ·2026-11-03 ·Qizhen Lan, Yu-Chun Hsu, Yuxiang Wei, Lijing Zhu, Zenan Sun +3 more
top venuecode/data similarity 0.62
Abstract · Accepted at NeurIPS 2026, Evaluations and Datasets Track. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain; code: https://github…

Automatic tools can now generate whole-brain MRI parcellations at cohort scale, but generated-label releases often provide little evidence about which cases are reliable enough to reuse. We introduce OpenBrain, a confidence-aware release of 35,838 provenance-verified OpenNeuro T1w cases from 607 source datasets. OpenBrain is organized as an auditable case-record release rather than a directory of standalone segmentation files: each record links a primary parcellation, two committee parcellations, source/license provenance, raw QC-7 measurements, percentile risks, a combined risk score R, and a confidence tier. QC-7 is a reference-free reliability panel over label geometry, image-label consistency, and committee disagreement, so users can filter, weight, audit, or re-threshold generated labels without rerunning inference. We evaluate this released evidence under a frozen protocol. Across external cohorts, lower QC-7 risk corresponds to higher generated-label quality; in fixed-budget training, lower-risk selections improve paired macro Dice over random selection by +3.2 to +3.7 percentage points. OpenBrain also exposes raw axes, committee outputs, provenance, and datasheet documentation, so confidence claims remain inspectable after download. It does not turn generated labels into manual annotations or clinical-grade segmentations. Its contribution is a large open generated-parcellation substrate, a reusable case-level risk-evidence layer, and an external validation protocol for release-time QC. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain. Code: https://github.com/lanqz7766/openbrain.

0.44

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions

eess.IV ·2026-10-15 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
similarity 0.61
Abstract · 8 pages, 4 figures

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

0.47

CropCop: An Auditable 120-Class Plant-Health Model from Benchmark Reconstruction to a Quantised Runtime Artifact

cs.CV cs.LG ·2026-08-26 ·Rana Muhammad Ahmed, Sabahat Abbas
benchmark similarity 0.59
Abstract · 25 pages, 6 figures, and 15 tables. Includes benchmark-audit, model-retention, runtime-fidelity, and reproducibility appendices

A plant-health score can appear precise while resting on duplicated image families, a long-tailed label space, or a runtime file that was never evaluated. We present CropCop, a closed-set recognition system spanning 120 operational plant-health classes and an evidence chain from corpus reconstruction to direct execution of the final quantised artifact. Starting from 117,546 audited images, we rejected the inherited partition after confirming 3,233 duplicate relationships across split boundaries and froze a 109,107-image benchmark with zero crossings among the audited trusted leakage groups and a 151.7 largest-to-smallest class ratio. A fully fine-tuned DINOv3 ConvNeXt-Tiny reference achieved 98.51% accuracy and 96.87% macro-F1 on the locked internal test. A compact MobileNetV4 Conv-Medium derivative achieved 98.46% accuracy and 96.27% macro-F1 without being presented as evidence for a new distillation method. Validation-only post-training quantisation selected dynamic activations with per-channel weights, and the final 22.60 MiB ExecuTorch/XNNPACK PTE achieved 98.46% accuracy and 96.23% macro-F1 when executed directly. Only six of 16,363 top-1 decisions changed between the converted INT8 graph and the PTE, while paired analysis showed a modest class-balanced loss; an exploratory post hoc fruit-label slice localized a larger recall decline than aggregate accuracy revealed. CropCop establishes strong leakage-controlled internal recognition and software-runtime fidelity; it does not establish performance on unseen farms, camera pipelines, or physical Android hardware.

0.38

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.59
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.44

Exact Dice Degradation Envelopes for Label-Free Segmentation Update Selection

eess.IV cs.LG ·2026-10-01 ·Yuvraj Verma
similarity 0.58
Abstract · 18 pages, 7 figures, 6 tables. Includes mathematical proofs and a three-seed study on ClinicDB, Massachusetts Buildings, and Kvasir-SEG

Test-time segmentation updates can improve an unlabeled input while damaging another. Confidence and transformation consistency can rank candidates, but do not in themselves bound the loss caused by returning a changed mask. We derive the exact largest decrease in binary Dice between a baseline and a candidate, maximized over every possible unknown reference mask on the same pixels. A maximizing reference always lies inside baseline foreground: three observable mask counts reduce the problem to at most four reference-cardinality checks. Accepting an output only when its envelope is below a budget gives a deterministic, per-case Dice degradation limit relative to the baseline. A finite grid of logit interpolations permits partial candidate outputs without extra network forwards. Exhaustive and randomized validation checks 5,026,592 reference masks with no discrepancy. We evaluate six independently trained MK-UNet sources, three seeds per task, on ClinicDB, Massachusetts Buildings and the external Kvasir-SEG cohort, including appearance corruptions. Across 17,808 case-condition-seed evaluations, 0 certificate violations occur in the checked candidate comparisons. At a one-point Dice budget, exact versus loose interpolation changes the returned mask in the following fractions of episodes (ClinicDB: 51.0% versus 38.7%; Buildings: 62.1% versus 53.1%; Kvasir-SEG: 52.3% versus 34.9%). Mean Dice effects and useful-update rejection are reported separately from admissibility. An exploratory oracle-presence-bit ablation examines how weak supervision relaxes the empty-baseline restriction. The envelope quantifies relative mask-change risk; it does not certify anatomical correctness, preserve other metrics, or guarantee adaptation benefit.

0.33

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.58
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24

Different Models, Shared Failures: Auditing Frozen-Encoder Pools for Medical Segmentation

cs.CV cs.AI ·2026-10-30 ·Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim
top venuecode/datahot direction similarity 0.58
Abstract · Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 47 pages, 8 figures. Code and data: https://github.com/eunseobchoi/CoFailMed

Average segmentation accuracy and model count do not reveal whether models fail on the same cases. We present CoFailMed, an audit of correlated failures in pretrained-encoder pools for medical segmentation. Across five 2D tasks, we evaluate 11 public pretrained encoders (a controlled sample, not a census) using frozen features and separately trained $1\times 1$ readouts with four seeds per encoder. Shared-checkpoint pairs have the highest mean per-case Dice correlation. An expanded 17-encoder analysis shows that distinct checkpoints within the same encoder family remain more correlated than cross-family pairs. At the pooled 33rd-percentile Dice threshold, four-member pools drawn from distinct encoders have mean effective sizes of 1.56-2.92, estimated from failure correlations in pools with enough failures and passes per member. In the primary pool, richer readouts and fine-tuning narrow the Dice-correlation gap between pairs sharing a checkpoint (or the DINOv2-B/S release) and all other pairs. Yet dependence between different encoders can increase, and fine-tuning does not consistently increase effective pool size at 33rd-percentile thresholds recomputed for each training recipe. A smaller between-group gap can coexist with greater dependence. Pool evaluation should therefore report absolute dependence and threshold-specific effective size alongside accuracy and nominal pool size. The CoFailMed release provides aligned per-case traces, analysis scripts and study code to reproduce the central audit results.

0.63