CS Paper Radar

Surveying Experimentally-Validated Components for DNA-Based Molecular Communication

Andreas Waldner, Regine Wendt, Nils Stumpf, Sarah Scheer, Christian Hyttrek, Stefan Fischer, Florian-Lennert Lau

cs.ET ·submitted 2026-10-16 12:08 UTC · v1
surveyunusual

Abstract

Molecular communication is a novel paradigm for the design of nanonetworks. It uses molecules as information carriers and enables communication between nanodevices. DNA-based molecular communication is a promising approach for medical applications, such as in-body networks for diagnostics and drug delivery. However, the transition from theoretical models to practical experiments is still in its early stages. This survey reviews experimentally validated DNA-tiles, nanocarriers, and biosensors relevant to implementing DNA-tile-based nanonetworks in vitro. We evaluate these components based on their stability, compatibility, cost-effectiveness, and overall suitability for wet-lab implementation. Based on this analysis, we identify promising component combinations and derive a blueprint for a minimal proof-of-concept experiment. The resulting framework provides researchers with both a structured overview of experimentally relevant design choices and a concrete starting point for implementing and validating DNA-based nanonetworks in the wet lab.

Comment
28 pages, 7 Tables, 8 Figures, under submission for IEEE COMST

Closest papers

Nearest neighbours by meaning across the whole index.

Autonomous Receptor Tuning via Integral Feedback for Adaptive Molecular Communication Receivers

cs.ET ·2026-10-04 ·Yagiz Celhan, Murat Kuscu
theory similarity 0.50
Abstract

Molecular communication (MC) uses molecules as information carriers among engineered cells and artificial devices in the Internet of Bio-Nano Things. MC receivers commonly employ ligand receptors, whose discrimination between the two received concentration levels of binary signaling depends on their position relative to the dissociation constant. Changes in the transmitter-receiver distance, ligand degradation, and interference can shift both levels below or above the dynamic range of fixed receptors, impairing detection. Previous work restored performance by externally tuning the dissociation constant to the geometric mean of the estimated received levels. In this paper, inspired by receptor adaptation in living cells, we investigate a receiver whose intracellular antithetic integral feedback network senses the receptor occupancy and autonomously tunes the dissociation constant through a modulator molecule. For constant received levels and equiprobable bits, we prove that, without knowing these levels, the network sets the dissociation constant at equilibrium to their geometric mean, which minimizes the bit error probability (BEP) for any fixed receptor cooperativity. We derive the gain, bandwidth, noise, and stability boundary of this feedback loop. The random bits averaged by the network induce self-noise, which sets an error floor independent of the network molecule count and, balanced against the channel-tracking error, yields a loop-speed design rule. For received levels varying fivefold over a coherence time of 24 loop time constants, adaptation reduces the BEP 61-fold for non-cooperative and 410-fold for cooperative receptors, compared with the best non-adaptive receiver. This benefit grows with the coherence time and peaks at moderate variation depths.

0.09

A Copper-Inducible Yeast Biosensor with Bioluminescent Readout: Mathematical Modeling, Experimental Validation, and Photodetector Coupling for Molecular Communication in IoBNT

cs.ET ·2026-11-17 ·Nikolaos Ntetsikas, Styliana Kyriakoudi, Ariel Klavaris, Antonis Kirmizis, Chrysostomos Chrysostomou +2 more
top venueunusual similarity 0.48
Abstract

Engineered living biosensors constitute promising model organisms for bringing Molecular Communications (MC) closer to practical applications. However, challenges associated with their development and characterization have resulted in the relevant literature being limited in the MC domain, . In this paper, we contribute in this direction by leveraging engineered yeast as a basis to detect heavy metals such as copper. The biosensor's development is supported by a validated mathematical characterization and analysis for possible integration in an MC system. Different from the existing literature, mathematical representations of the major biological processes within the yeast copper detoxification pathway are integrated into a comprehensive framework that predicts the time evolution of the CUP1 gene, which is treated as the system output. In the engineered circuit, CUP1 was replaced with GFP, therefore making GFP fluorescence the final system output. Experimental analysis including mRNA transcript quantification and fluorometric measurements, validate the GFP reporting model to a satisfactory degree. This establishes the proposed model as a useful tool for virtual experimentation and the developed testbed as a suitable platform for further engineering of yeast-based copper sensors. The theoretical analysis is further extended by incorporating a self-sustained bioluminescent reporter for yeast, replacing GFP and enabling optical output without external light excitation. The optical response is coupled to a photodetector model, rendering the system suitable for integration into mobile monitoring devices such as Smart Pills. The presented characterization of the yeast receiver as a copper biosensor, constitutes the first step towards the development and characterization of a complete end-to-end MC based system for gut theranostics after coupling with suitable engineered probiotic senders.

0.53

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

cs.ET ·2026-11-02 ·Alexander Wietfeld, Luiz C. P. Wille, Pit Hofmann, Jonas Fuchtmann, Randy Gelfert +3 more
similarity 0.47
Abstract · 6 pages, 8 figures; submitted to IEEE ICC for review; Alexander Wietfeld and Luiz C. P. Wille contributed equally to this work

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

0.28

Array-Based Molecular Pulse Encoding for Neuro-Spike Communication in Intra-Body Nano-networks

cs.NI ·2026-08-18 ·Keyvan Aghababaiyan
similarity 0.47
Abstract

In this paper, we investigate a neuro-spike communication system designed to bridge severed connections between damaged neurons using auxiliary nano-machines. Natural neuro-spike communication typically relies on instantaneous spike rates and temporal intervals to convey information. However, these temporal encoding schemes require exact time synchronization between the transmitter and receiver, a requirement that poses a significant challenge for resource-constrained nano-machines. To address this issue, it is imperative for future intra-body nano-networks to develop communication schemes that operate under reduced-order synchronization (e.g., symbol-synchronized). In this paper, we propose a novel neuro-spike array-based communication scheme where information is encoded through the specific arrangement of distinct molecular pulses emitted by nano-machines. By distinguishing symbols based on the sequence of these emissions rather than their exact timing, the need for stringent time synchronization is eliminated. We theoretically analyze the performance of the proposed scheme by deriving expressions for the probability of inter-symbol interference (ISI), error probability, and the achievable communication rate. Analytical and numerical results demonstrate that our array-based scheme significantly outperforms previously proposed symbol-synchronized models, providing a 75% - 150% enhancement in the communication rate across various diffusion coefficients.

0.26

Analytical Modeling of Open- and Closed-Loop Dispersive Molecular Communication Channels with Pulsatile Flow

cs.ET physics.flu-dyn ·2026-10-07 ·Theofilos Symeonidis, Fardad Vakilipoor, Timo Jakumeit, Robert Schober, Nunzio Tuccitto +1 more
published similarity 0.42
Abstract · 15 pages, 8 figures. This paper substantially extends the preliminary version presented at the 13th ACM International Conference on Nanoscal…

Molecular communication (MC) is a communication paradigm in which information is conveyed through the release, propagation, and reception of molecules. Many envisioned healthcare applications of MC are expected to operate inside the human body, where the cardiovascular system (CVS) may serve as the physical propagation environment and molecular transport is governed by diffusion and blood flow. Although blood flow is inherently pulsatile, most analytical MC channel models assume steady flow. In this paper, we develop a time-variant analytical model for dispersive MC channels with pulsatile flow. We derive the straight-duct response as a Normal distribution with time-variant mean and variance, capturing the combined effects of diffusion and pulsatile flow, and extend it to closed-loop channels through a wrapped-Normal representation. The model is validated against three-dimensional (3D) particle-based simulations (PBSs) for synthetic and physiologically motivated velocity waveforms. We further derive a closed-form first-order approximation for the first-arrival peak time and introduce the nondimensional indicator $S_{\mathrm{Rx}}$ for assessing the applicability of the reduced one-dimensional (1D) model. Our results show that pulsatility has the strongest influence when molecular transport is predominantly advective and the temporal flow variations are not averaged out, whereas stronger diffusion and faster pulsations reduce its impact on the received signal. Moreover, a PBS-based parameter sweep supports $S_{\mathrm{Rx}} \ge 2$ as a practical criterion for the applicability of the proposed analytical model. Finally, relating the analytical assumptions to representative blood-vessel classes shows that model applicability depends not only on the transport conditions but also on physiological properties such as vessel rigidity, geometric uniformity, and blood rheology.

0.39

Learning When to Listen: Physics-Informed Synchronization in Molecular Channels

eess.SP ·2026-10-16 ·Osman Tugay Basaran, Saswati Pal, Falko Dressler, Jorge Torres Gómez
similarity 0.42
Abstract

Recent advances in chemical computing create new opportunities to realize biocompatible communication devices for application in precision medicine. Implanted microscopic transmitters and receivers can exchange information using molecules that diffuse through a biological medium, enabling them to form a network and jointly coordinate sensing and actuation operations. However, randomness in molecular propagation causes severe signal distortion, and receivers have limited computational capacity to compensate. The receiver design must therefore combine robustness to diffusion-induced distortion with computational architectures amenable to implementation in the chemical domain. To meet these requirements, we propose a physics-informed reinforcement learning (RL) framework implemented with the reservoir computing (RC) architecture. We study the task of synchronizing the receiver's clock with a sequence transmitted through a molecular communication (MC) channel. The physics part approximates the maximum-likelihood function synchronization objective, while the other learns a timing policy using this objective as its reward. Simulation results yield clock misalignments above half a second, compatible with molecular transmissions operating on the timescale of seconds.

0.24

Molecular LLM Agents: From Architectural Design to Scientific Autonomy

cs.CL cs.AI ·2026-08-24 ·Jiatong Li, Wengyu Zhang, Weida Wang, Yuxuan Ren, Wei Liu +6 more
similarity 0.42
Abstract · 25pages

Molecular science represents an important frontier for LLM-based agents. Unlike general agents that mainly operate over natural language, code, or web environments, molecular LLM agents must perceive, reason about, and act upon chemical objects across symbolic strings, molecular graphs, 3D conformations, spectra, simulations, and wet-lab measurements. Their capabilities depend on chemically faithful molecular perception, an LLM-centered agent framework, domain-specific tool grounding, and computational or experimental feedback, in addition to planning and tool use. This work develops a conceptual framework for molecular LLM agents from two complementary perspectives. First, we introduce an architectural view of molecular-agent design, covering molecular representation and perception, the agent framework, domain-specific toolboxes, and learning and optimization. Second, we propose a scientific autonomy ladder inspired by staged autonomy in engineering systems, categorizing agents into four levels: L1 assistive or fixed workflows, L2 adaptive computational agents, L3 feedback-aware physical experiment agents, and L4 scientific-agenda agents. Together, these two perspectives establish a comprehensive framework for comparing existing molecular LLM agents, identifying missing capabilities and deployment risks, and guiding the design, evaluation, and deployment of future agents in molecular discovery workflows.

0.23

Receiver-Surface Hit Patterns via Legendre Approximation for Molecular Signal Detection

cs.IT cs.LG ·2026-09-10 ·Yasin Bastug, Erencem Ozbey, H. Birkan Yilmaz
unusual similarity 0.42
Abstract · 5 pages, 4 figures

Detecting whether a transmitter is actively communicating with a receiver is a fundamental problem in molecular communications. A spherical receiver may measure not only the number and arrival times of absorbed molecules, but also their absorption locations on the receiver surface. These locations contain a directional signature that is lost in count-only detection. In this letter, we develop a molecular signal detector based on a Legendre polynomial expansion of the receiver-surface hit density and extend it to a Legendre-based Viterbi sequence detector. By exploiting the surface-level directional signature of molecular arrivals, the proposed detectors provide geometry-aware, efficient, and better-performing alternatives to count-only detection.

0.29