CS Paper Radar

Receiver-Surface Hit Patterns via Legendre Approximation for Molecular Signal Detection

Yasin Bastug, Erencem Ozbey, H. Birkan Yilmaz

cs.IT cs.LG ·submitted 2026-09-10 18:15 UTC · v1
unusual

Abstract

Detecting whether a transmitter is actively communicating with a receiver is a fundamental problem in molecular communications. A spherical receiver may measure not only the number and arrival times of absorbed molecules, but also their absorption locations on the receiver surface. These locations contain a directional signature that is lost in count-only detection. In this letter, we develop a molecular signal detector based on a Legendre polynomial expansion of the receiver-surface hit density and extend it to a Legendre-based Viterbi sequence detector. By exploiting the surface-level directional signature of molecular arrivals, the proposed detectors provide geometry-aware, efficient, and better-performing alternatives to count-only detection.

Comment
5 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Exact Cap Response and Aperture Selection for Molecular Communication under Aligned Drift

cs.IT cs.ETeess.SP ·2026-10-14 ·Yen-Chi Lee, Chun-An Yang, Nan Yang
similarity 0.55
Abstract · 7 pages, 3 figures, 2 tables. Full version including two appendices. A shortened version omitting Appendix A is being prepared for submissio…

Spatial reception under directed molecule transport requires balancing useful molecule capture against intersymbol interference (ISI). To characterize this balance, we study a fully absorbing spherical receiver that counts absorption events only within a prescribed cap. Using the known joint first-hitting law under aligned drift, we derive exact cap impulse, cumulative, and eventual responses. We perform stable cumulative evaluation. We then assess the derived responses through particle simulations and time-step comparisons, and demonstrate that our conditional-timing analysis explains when opposite drifts of equal magnitude can favor the same wider aperture. We also show that for the studied geometry and a symbol duration of $0.15$ s, the aperture that maximizes the signal-to-interference difference (SID) increases from $29.13^\circ$ at zero drift to $61.86^\circ$ at a drift magnitude of $40$ $μ$m/s. These results (i) connect joint arrival-time and location statistics to spatial reception design, (ii) characterize the tradeoff between useful molecule capture and ISI, (iii) support SID-based aperture selection for a given drift and symbol duration, and (iv) quantify the SID loss incurred by retaining the zero-drift optimal aperture for the same symbol duration.

0.32

A Closed-Form Molecule-Release Rule for Diffusion-Based Molecular Communications with Ligand Receptors

cs.ET ·2026-09-17 ·Eren Kural, Murat Kuscu
unusual similarity 0.49
Abstract

The number of molecules released per bit is a fundamental design variable of diffusion-based molecular communication (MC), and ligand-receptor reception breaks the more-is-better intuition. Too few molecules leave the bound-receptor observations buried in binding noise, while too many amplify the accumulated intersymbol interference and saturate the finite receptor population, again making the observations indistinguishable. Reliability therefore peaks in an interior operating region whose location seems to require an exhaustive search over the channel dynamics. In this paper, we show that this search can be obviated for a biologically plausible receiver that compares consecutive bound-receptor counts without channel state information or a decision threshold. We derive a closed-form transmission rule, which sets the number of molecules released per bit such that the receptor dissociation constant equals the geometric mean of the two bit-conditioned received concentration levels, prove that it exactly minimizes the bit error probability of a memoryless binomial receptor model, and express it in the physical channel parameters through an Euler--Maclaurin evaluation of the interference. Time-domain Monte Carlo sweeps of the channel and receptor parameters, corroborated by particle-based simulations, show that the empirically optimal release count coincides with the prediction or lies above it by a small factor.

0.26

Noise Characterization and Robust Signal Detection in Yeast Pheromone Molecular Communication

cs.IT cs.ET ·2026-11-17 ·Nikolaos Ntetsikas, Styliana Kyriakoudi, Antonis Kirmizis, Ioannis Krikidis, Ian F. Akyildiz +1 more
top venueunusual similarity 0.46
Abstract

A critical aspect of Molecular Communications (MC) is the implementation of signal detection policies amidst noise. To date, noise characterizations within the MC field have predominantly drawn from methodologies found in wireless communications literature. In this study, we diverge from existing MC research by utilizing a newly developed experimental platform that employs yeast, allowing us to consider more realistic noise characterizations based on the relevant signaling pathways. We propose suitable signal detection mechanisms tailored to this experimental setup, which focuses on yeast cell-to-cell communications. Our analysis identifies gene transcription as the primary source of noise, and we utilize a Markov birth-death process model with Poisson arrivals and departures to characterize it. The noisy expression of the FUS1 gene is best represented using a mixed Gaussian distribution model. This model serves as a foundation for evaluating the performance of Maximum Likelihood Detection mechanisms in terms of Bit Error Rate (BER) for both symbol-by-symbol and sequence transmission schemes. Error analysis indicates that appropriate adjustments to the signal threshold can reduce errors to as low as 10%, which is not negligible. In contrast, the detection of symbol sequences demonstrates enhanced error performance, achieving error rates as low as 0.4%, albeit at the cost of increased computational complexity.

0.71

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

cs.ET ·2026-11-02 ·Alexander Wietfeld, Luiz C. P. Wille, Pit Hofmann, Jonas Fuchtmann, Randy Gelfert +3 more
similarity 0.44
Abstract · 6 pages, 8 figures; submitted to IEEE ICC for review; Alexander Wietfeld and Luiz C. P. Wille contributed equally to this work

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

0.28

Autonomous Receptor Tuning via Integral Feedback for Adaptive Molecular Communication Receivers

cs.ET ·2026-10-04 ·Yagiz Celhan, Murat Kuscu
theory similarity 0.44
Abstract

Molecular communication (MC) uses molecules as information carriers among engineered cells and artificial devices in the Internet of Bio-Nano Things. MC receivers commonly employ ligand receptors, whose discrimination between the two received concentration levels of binary signaling depends on their position relative to the dissociation constant. Changes in the transmitter-receiver distance, ligand degradation, and interference can shift both levels below or above the dynamic range of fixed receptors, impairing detection. Previous work restored performance by externally tuning the dissociation constant to the geometric mean of the estimated received levels. In this paper, inspired by receptor adaptation in living cells, we investigate a receiver whose intracellular antithetic integral feedback network senses the receptor occupancy and autonomously tunes the dissociation constant through a modulator molecule. For constant received levels and equiprobable bits, we prove that, without knowing these levels, the network sets the dissociation constant at equilibrium to their geometric mean, which minimizes the bit error probability (BEP) for any fixed receptor cooperativity. We derive the gain, bandwidth, noise, and stability boundary of this feedback loop. The random bits averaged by the network induce self-noise, which sets an error floor independent of the network molecule count and, balanced against the channel-tracking error, yields a loop-speed design rule. For received levels varying fivefold over a coherence time of 24 loop time constants, adaptation reduces the BEP 61-fold for non-cooperative and 410-fold for cooperative receptors, compared with the best non-adaptive receiver. This benefit grows with the coherence time and peaks at moderate variation depths.

0.09

Predicting Collision Cross Sections with GRACE: Geometric Residual Adduct Conditioning via Early-fusion

cs.LG cs.AIq-bio.BM ·2026-09-10 ·Parthasarathy Suryanarayanan, Susanta Das, Shreyans Sethi, Kenneth M. Merz,, Joseph A. Morrone
similarity 0.42
Abstract · 35 pages, including 10 figures and 18 tables

Collision cross section (CCS), derived from ion mobility mass spectrometry, is a common descriptor for molecular annotation. Prediction is challenging for machine learning models because it reflects the size, shape, and ionization state of a gas-phase molecular ion. Most predictors either ignore explicit 3D structure or treat adduct identity as a late categorical feature, which limits their ability to capture adduct-dependent geometric effects. We present GRACE (Geometric Residual Adduct Conditioning via Early-fusion), a 3D CCS predictor that adapts a pretrained molecular geometry encoder using geometric residual adduct conditioning via early fusion. GRACE combines two inductive biases: a residual objective relative to an adduct-aware physical descriptor baseline and adduct conditioning within the encoder via a learned adduct token and low-rank attention adapters. We evaluate the model on a curated set of over 9,000 experimental molecule-adduct CCS records with random, scaffold, and adduct-sensitive splits designed to separate interpolation, scaffold generalization, and adduct-driven generalization. GRACE achieves the best mean percentage difference among the evaluated learned models on all three splits: 1.67% on the random split, 2.11% on the scaffold split, and 2.36% on the adduct-sensitive split. Diagnostic analyses suggest that residual learning stabilizes training by removing the dominant mass-CCS trend, while early fusion improves adduct-sensitive prediction relative to late fusion. Across four independent external test sets, GRACE shows consistently lower error than the other evaluated models. On a held-out set, GRACE also attains the lowest mean percent difference when compared with four previously reported physics-based workflows. These results support residual learning and encoder-level adduct conditioning as practical inductive biases for fast, accurate CCS prediction.

0.22

A Three-Axis Rydberg Atomic Receiver Model for Polarization-Based Direction-of-Arrival Sensing

eess.SP ·2026-10-13 ·Bangyan Xia, Bo Tan
benchmark similarity 0.42
Abstract

This paper develops a three-axis Rydberg atomic receiver model for direction-of-arrival (DoA) estimation of the radio frequency (RF) signal source. Three nominally orthogonal RF local oscillators (LOs), each assigned a distinct frequency offset, project the weak incident RF field into resolvable complex beat coefficients in the optical readout. A beat-vector observation is obtained by adopting a response calibration mechanism that maps the coefficients onto the three axes of the Cartesian coordinate system. For a known circularly polarised RF signal, this observation induces a direction-dependent Rydberg steering vector, enabling maximum-likelihood DoA estimation. The pro posed procedure translates the Rydberg beat-vector front end into a highly sensitive RF field DoA sensor. Simulation results show that trace-level beat extraction supports the proposed DoA sensing workflow and provides a basis for comparison with a traditional vector antenna (VA) benchmark.

0.22

Surveying Experimentally-Validated Components for DNA-Based Molecular Communication

cs.ET ·2026-10-16 ·Andreas Waldner, Regine Wendt, Nils Stumpf, Sarah Scheer, Christian Hyttrek +2 more
surveyunusual similarity 0.42
Abstract · 28 pages, 7 Tables, 8 Figures, under submission for IEEE COMST

Molecular communication is a novel paradigm for the design of nanonetworks. It uses molecules as information carriers and enables communication between nanodevices. DNA-based molecular communication is a promising approach for medical applications, such as in-body networks for diagnostics and drug delivery. However, the transition from theoretical models to practical experiments is still in its early stages. This survey reviews experimentally validated DNA-tiles, nanocarriers, and biosensors relevant to implementing DNA-tile-based nanonetworks in vitro. We evaluate these components based on their stability, compatibility, cost-effectiveness, and overall suitability for wet-lab implementation. Based on this analysis, we identify promising component combinations and derive a blueprint for a minimal proof-of-concept experiment. The resulting framework provides researchers with both a structured overview of experimentally relevant design choices and a concrete starting point for implementing and validating DNA-based nanonetworks in the wet lab.

0.31