CS Paper Radar

Physiology-Aware Graph Attention for Early Ventricular Reentry Prediction

Ma{ë}lis Morier, Jairo Rodr{í}guez Padilla, Patrick Gallinari, Maxime Sermesant

cs.AI ·submitted 2026-10-19 13:55 UTC · v1

Abstract

Sudden cardiac death mostly originates from post-infarct ventricular tachycardia. This reentry is sustained by propagation around scar tissue, but its risk remains difficult to predict from infarct imaging alone. While in silico induction studies can reveal these mechanisms, exploring many substrates and pacing locations remains computationally expensive. We propose a graph attention classifier for early prediction of sustained ventricular reentry from simulated cardiac electrophysiology. Each simulation is represented as a graph with early nodal voltage samples and edge attributes encoding geometry, stimulation frequency, tissue labels, amplitude, and diastolic interval. These descriptors are computed only from the first two paced activations, before sustained reentry is observed. On a balanced independent test set of 1000 simulations, the classifier achieves 94.6% accuracy, 95.4% sensitivity, 93.8% specificity, 94.6% F1-score, 0.987 ROC-AUC, and 0.985 PR-AUC. Ablation experiments show that diastolic interval is the most critical descriptor. Qualitative attention inspection suggests that different heads focus on border-zone, stimulation location, and early propagation path. These results support graph attention as a fast early-prediction approach for large-scale in silico ventricular reentry studies.

Journal ref
STACOM 2026 - 17th International Workshop on Statistical Atlases and Computational Models of the Heart, Sep 2026, Strasbourg, France

Closest papers

Nearest neighbours by meaning across the whole index.

Accurate and Auditable ECG Classification via Visibility Graph Neural Networks

cs.LG cs.AI ·2026-10-30 ·Artur Xavier, Guilherme Henrique Gomes Evangelista, Aitazaz Khan, Antonio Luiz Pinho Ribeiro, Mohammed J. Zaki +2 more
hot direction similarity 0.66
Abstract · 43 pages, 10 figures, 21 tables, including Supplementary Information

Physicians read electrocardiograms (ECGs) from waveform shape and timing, yet accurate deep-learning classifiers rarely show which waveform regions drive their predictions. We introduce LYNX-ECG, a graph neural network that represents each heartbeat as a sparse visibility graph of timestamped turning points. On CODE-Test, LYNX-ECG reaches a macro F1 score of 0.889, outperforming five baselines including the ECGFounder foundation model, while its graphs need about 14% of the storage of graphs built from every sample. Because each node maps to a specific ECG time, we can delete clinically defined waveform regions and alter beat timing to audit predictions. For conduction disorders, the clinically expected region was the strongest evidence in more than 90% of correct predictions. Bradycardia and tachycardia calls follow heart rate with conduction intervals held fixed, and atrial fibrillation calls vanish when beat-to-beat variation is removed. Sparse visibility graphs thus pair accurate ECG classification with clinically grounded, testable explanations.

0.31

Characterising cardiac tissue properties with graph neural networks

cs.AI q-bio.QMeess.SP ·2026-08-16 ·Ching-En Chiu, Yoo Ri Kim, Magdi Saba, Danilo Mandic, Marta Varela
similarity 0.65
Abstract · Accepted at The Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop 2026

Characterising electrophysiological properties of cardiac tissue efficiently and accurately from spatially sparse intracardiac measurements is clinically important for localising ablation targets and improving arrhythmia treatment. We developed a graph neural network-based framework trained on synthetic electrogram signals on 2D flat surfaces to identify areas of interest in the context of cardiac ablation for premature ventricular complexes (PVCs). Our method achieved an average precision of 0.96, 0.97, and 0.95 for the detection of single-patch fibrosis, rapid depolarisation and high excitability, respectively. The trained model can then be applied to 2D curved surfaces with few-shot fine-tuning, demonstrating its generalisation capability. Future work will develop this framework further for clinical use in PVC ablation.

0.13

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.61
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.21

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.61
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.60
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.60
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.23

BeatGraph: Self-Supervised Heartbeat Graphs for Infant ECG Representations from the Home Environment

cs.LG ·2026-09-25 ·Mohammad Nur Hossain Khan, M. S. Krafczyk, Beverly G. Bolster, Nancy McElwain, Mark A. Hasegawa-Johnson +1 more
benchmark similarity 0.59
Abstract

Electrocardiogram (ECG) foundation models typically tokenize the signal into fixed-length patches that ignore cardiac structure, so a patch may split a heartbeat and the number of beats in each patch shifts with heart rate. This matters most for infants, whose heart rates are higher and whose ECG differs from the adult, clinic-recorded 12-lead data these models are built on. A model for infant ECG should therefore reason about heartbeats directly rather than recover them from arbitrary patches. We propose BeatGraph, which makes the heartbeat its unit of representation, modeling each 30-second window as a graph of beats. A shared beat encoder embeds each heartbeat from its waveform and inter-beat intervals, a Transformer with positional encoding orders the beats in time, and residual graph attention layers relate every beat to every other before attention pooling yields a window embedding. We pretrain BeatGraph on our new corpus of unlabeled infant recordings by predicting masked-beat embeddings, then fine-tune it for each task. One backbone supports sleep-wake detection, infant-state classification, activity-source identification (infant- or caregiver-initiated movement), and affect recognition, improving macro-F1 over the strongest baseline on each task by 0.076 to 0.158. It also transfers across age groups, reaching 0.892 AUROC on the ZZU-pECG pediatric benchmark (ages 0 to 14), within 0.001 of the best published self-supervised ECG model, and matching that model under linear evaluation on the adult PTB-XL benchmark despite infant-only pretraining. Finally, to our knowledge, we release the first public infant ECG corpus collected in homes, classrooms, and laboratory settings with state and affect labels. It contains 3,408 hours of single-channel ECG from 143 infants aged 3 to 11 months, with unlabeled pretraining data, benchmark tasks, and subject-level splits.

0.26

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

cs.LG ·2026-08-27 ·Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya +2 more
published similarity 0.59
Abstract · 7 pages, 7 figures. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026…

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.

0.32