CS Paper Radar

Characterising cardiac tissue properties with graph neural networks

Ching-En Chiu, Yoo Ri Kim, Magdi Saba, Danilo Mandic, Marta Varela

cs.AI q-bio.QMeess.SP ·submitted 2026-08-16 16:31 UTC · v1

Abstract

Characterising electrophysiological properties of cardiac tissue efficiently and accurately from spatially sparse intracardiac measurements is clinically important for localising ablation targets and improving arrhythmia treatment. We developed a graph neural network-based framework trained on synthetic electrogram signals on 2D flat surfaces to identify areas of interest in the context of cardiac ablation for premature ventricular complexes (PVCs). Our method achieved an average precision of 0.96, 0.97, and 0.95 for the detection of single-patch fibrosis, rapid depolarisation and high excitability, respectively. The trained model can then be applied to 2D curved surfaces with few-shot fine-tuning, demonstrating its generalisation capability. Future work will develop this framework further for clinical use in PVC ablation.

Comment
Accepted at The Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Physiology-Aware Graph Attention for Early Ventricular Reentry Prediction

cs.AI ·2026-10-19 ·Ma{ë}lis Morier, Jairo Rodr{í}guez Padilla, Patrick Gallinari, Maxime Sermesant
similarity 0.65
Abstract

Sudden cardiac death mostly originates from post-infarct ventricular tachycardia. This reentry is sustained by propagation around scar tissue, but its risk remains difficult to predict from infarct imaging alone. While in silico induction studies can reveal these mechanisms, exploring many substrates and pacing locations remains computationally expensive. We propose a graph attention classifier for early prediction of sustained ventricular reentry from simulated cardiac electrophysiology. Each simulation is represented as a graph with early nodal voltage samples and edge attributes encoding geometry, stimulation frequency, tissue labels, amplitude, and diastolic interval. These descriptors are computed only from the first two paced activations, before sustained reentry is observed. On a balanced independent test set of 1000 simulations, the classifier achieves 94.6% accuracy, 95.4% sensitivity, 93.8% specificity, 94.6% F1-score, 0.987 ROC-AUC, and 0.985 PR-AUC. Ablation experiments show that diastolic interval is the most critical descriptor. Qualitative attention inspection suggests that different heads focus on border-zone, stimulation location, and early propagation path. These results support graph attention as a fast early-prediction approach for large-scale in silico ventricular reentry studies.

0.40

Accurate and Auditable ECG Classification via Visibility Graph Neural Networks

cs.LG cs.AI ·2026-10-30 ·Artur Xavier, Guilherme Henrique Gomes Evangelista, Aitazaz Khan, Antonio Luiz Pinho Ribeiro, Mohammed J. Zaki +2 more
hot direction similarity 0.62
Abstract · 43 pages, 10 figures, 21 tables, including Supplementary Information

Physicians read electrocardiograms (ECGs) from waveform shape and timing, yet accurate deep-learning classifiers rarely show which waveform regions drive their predictions. We introduce LYNX-ECG, a graph neural network that represents each heartbeat as a sparse visibility graph of timestamped turning points. On CODE-Test, LYNX-ECG reaches a macro F1 score of 0.889, outperforming five baselines including the ECGFounder foundation model, while its graphs need about 14% of the storage of graphs built from every sample. Because each node maps to a specific ECG time, we can delete clinically defined waveform regions and alter beat timing to audit predictions. For conduction disorders, the clinically expected region was the strongest evidence in more than 90% of correct predictions. Bradycardia and tachycardia calls follow heart rate with conduction intervals held fixed, and atrial fibrillation calls vanish when beat-to-beat variation is removed. Sparse visibility graphs thus pair accurate ECG classification with clinically grounded, testable explanations.

0.31

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

cs.LG ·2026-08-27 ·Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya +2 more
published similarity 0.58
Abstract · 7 pages, 7 figures. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026…

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.

0.32

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.56
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

A New AFIB Detection Method with Deep Neural Networks

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ana Angjelevska, Dimitar Trajanov, Marjan Gusev
benchmarkhot direction similarity 0.55
Abstract · 10 pages, 7 tables, 3 formulas

Early detection of atrial fibrillation (AFIB), characterized by irregular heart rhythms, can potentially save thousands of lives annually [20]. Numerous studies have attempted to address this challenge using various algorithms and methodologies. This paper introduces a novel and robust method that enhances the precision of AFIB detection. Neural Networks (NN) are widely recognized for their ability to identify complex electrocardiogram (ECG) patterns, facilitating the accurate detection of irregular heart rhythms. This study explores multiple conventional machine learning algorithms alongside neural network approaches to develop a robust AFIB detection system. To evaluate the effective- ness and robustness of the proposed method, the MIT BIH arrhythmia database (MITDB) and the Long-term Atrial Fibrillation Database (LTAFDB), both available on the Physionet site. Our approach presents a novel feature engineering technique, employing specific features such as a time series of the differences in successive heart rates (dBPM) rather than traditional inter-beat intervals. The model analyzes inputs labeled into five distinct classes, using only clean intervals identified through a new labeling method for training while treating others as outliers. This strategy ensures a more accurate and reliable AFIB detection process. The best-performing model, a Deep Neural Network (DNN), achieved an F1 score of 95.18% for binary atrial fibrillation classification on a benchmark dataset distinct from the training set. Models trained using our approach have demonstrated superior performance than previously published models.

0.47

Mean Curvature Minimizing Foliations Of A Vector Field

cs.CV ·2026-11-18 ·Tabish A. Syed, Marc Theveneau, Benedikt Wirth, Rustum Choksi, Kaleem Siddiqi
similarity 0.54
Abstract

Streamline patterns are ubiquitous in nature. Prominent examples include white matter fibre tracts in the mammalian brain and arrangements of elongated cells, such as cardiomyocytes in the heart wall. It has been posited that such organisations foliate into locally smooth surfaces to optimise function. However, the recovery of these foliations from a single vector field aligned with the local orientation of the underlying sheets remains an open problem. We address this challenge by introducing a mathematical model of a sheet and developing an algorithm for sheet inference, from measurements of the oriented structures. Given an input vector field, our model estimates a second vector field that is orthonormal to it, while also requiring the Lie bracket of the two to vanish. To balance sheet likelihood against low surface area, we also reduce the mean curvature of the recovered local surface. We compute the first variation of an associated energy and provide a numerical method which admits an efficient, parallel implementation for sheet estimation. We demonstrate our approach on both synthetic and biological examples, motivated by applications to medical imaging. These include white matter fibre tracts from a brain atlas and confocal microscopy images of cleared heart wall tissue. For the latter we are able to reconstruct sheets aligned with local cardiomyocyte directions at unprecedented (micrometre) scale.

0.24

GNN-Enhanced TCN Algorithms for ECG Anomaly Detection

cs.LG ·2026-11-12 ·Angelica Simonetti, Ferdinando Zanchetta
published similarity 0.54
Abstract · Follow-up to arXiv:2310.02774, which introduced a pipeline for an industrial dataset. A shortened version of that earlier paper appeared in …

To a time series can be also given the structure of directed graph, opening the doors to the usage of graph neural networks (GNNs) in this context. In this paper we develop a new pipeline involving novel geometric deep learning models that merge the capabilities of ordinary TCNs with the ones of GNNs to solve an anomaly detection problem on electrocardiogram signals.

0.25

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.54
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28