Abstract

Cytokine-mediated inflammation disorders such as sepsis and cytokine release syndrome demand bedside multiplex panels that resolve pro- and anti-inflammatory dynamics in minutes, yet label-free FET cytokine sensors remain limited to few devices, single analytes, and PDMS packaging that sorbs small molecules and leaches oligomers. We present a CMOS platform pairing a 128 x 128 ion-sensitive field-effect transistor (ISFET) array (SkyWater 130 nm, SiN gate) with a FlexDym 4 x 1 micro-well overlay that partitions the membrane into four chemically independent regions (approximately 2,176 pixels each, square-root-of-N averaging). Two wells carry capture antibodies (anti-IL-6, anti-IL-10), one is a non-specific reference, and one tests specificity; the transduced signal is defined as the differential current relative to the reference signal (Delta I_D(W_n) - Delta I_D(W_3)). Single-analyte dose-response measurements spanning 100 fM to 10 nM successfully resolve both IL-6 and IL-10 above the non-specific detection floor, including at healthy-serum baseline concentrations. The array shows a per-pixel pH sensitivity of 1.13 microamperes per pH unit (CV approximately 14%). Across two chips, device-to-device variation is dominated by transconductance spread (g_m CV approximately 62%); a one-time per-device g_m calibration reduces analyte-measurement variance to approximately 16%. We further validate the surface functionalization, characterize device-to-device variation, and demonstrate the FlexDym integration workflow. Simultaneous multiplexed cytokine measurements resolve IL-6 (W1) and IL-10 (W2) against the chemistry-only reference (W3). At the same time, cross-specificity characterization is assessed by applying IL-6 to an anti-IL-10 well (W4), establishing a scalable label-free ISFET architecture for multiplexed cytokine sensing.

Closest papers

Nearest neighbours by meaning across the whole index.

Computational De Novo Design of Miniprotein Candidate Neutralizers Targeting the IL-23 Cytokine Subunit p19

cs.LG q-bio.BM ·2026-10-23 ·Raghav Paladugu, Fardina Fathmiul Alam
published similarity 0.45
Abstract · Accepted as a short paper at the 2026 IEEE International Conference on Bioinformatics and Biomedicine (BIBM 2026)

Interleukin-23 (IL-23) drives T-helper-17 inflammation underlying inflammatory bowel disease and psoriasis; anti-p19 antibodies are clinically effective but large, costly, and injectable. De novo miniproteins are an attractive alternative, yet published designs target the IL-23 receptor; the IL-23 cytokine itself has not been addressed. A further obstacle is that the standard confidence score (ipTM) tracks construct length rather than interface quality. We computationally design miniprotein binders against the IL-23R-binding face of p19 (PDB 3DUH) and score every design with ipSAE, a length-robust interface metric derived from AlphaFold-initial-guess predicted aligned error. A conventional RFdiffusion/ProteinMPNN/ColabFold pipeline yields no reliable predicted interface across 972 designs (best ipSAE 0.30), and a scoring artifact, in which single-sequence ColabFold under-rates binder pLDDT by approximately 56 points, explains an earlier misleading "binders do not fold" signal. An interface-optimized hallucination method (BindCraft), scored identically, yields 42 of 50 designs above ipSAE 0.60 (best 0.804). An AlphaFold-independent geometric check reproduces the conventional failure: no top-ranked conventional design reaches the buried area or interface hydrogen-bond count of the weakest lead. Five all-alpha-helical leads (72-104 residues) collectively engage all six targeted hotspots; two dock within the intact p40/p19 heterodimer and all show favorable Rosetta energetics. A p40-alone counter-screen returns ipSAE 0.00 for all five, indicating no spurious p40 interface. To our knowledge, these are the first computationally proposed de novo miniprotein candidates designed to occlude the IL-23R-binding face of IL-23 p19. All results require experimental validation.

0.40

FLaG: Frequency-Domain Latent-attention Gated Pooling for Token Aggregation

cs.AI q-bio.BM ·2026-09-01 ·Kewei Li, Rongying Zhang, Xueli Wang, Xiwen Gong, Zhongjian Wang +4 more
code/data similarity 0.44
Abstract

Token aggregation converts token-level representations into fixed-dimensional sample representations, but most pooling methods operate only in the original token space. We introduce Frequency-Domain Latent-attention Gated Pooling (FLaG), a plug-in aggregation module that re-expresses encoder outputs in the Fourier domain before final pooling. FLaG represents the nonredundant rFFT spectrum through concatenated real and imaginary components, summarizes spectral tokens with learnable latent queries, derives a sample-conditioned channel gate, and reconstructs modulated token representations for downstream aggregation. We evaluate the same architecture across ESM2-based antimicrobial peptide (AMP) activity prediction, ResNet18 image classification on CIFAR-10 and CIFAR-100, and three RoBERTa-based language tasks. FLaG achieves the best macro-averaged Spearman correlation coefficient, RMSE, and Recall@50 across four AMP backbone-species settings and the highest top-1 accuracy on CIFAR 10. It also achieves the best mean results on five of seven language metrics, although mean pooling remains strongest on STSBenchmark. AMP-side mechanistic analyses reveal low-frequency prediction sensitivity across most encoder layers, with increased relative high-frequency sensitivity in the final layer, and pronounced peptide-specific positional responses. The residual gate broadly amplifies spectral channels while preserving the low-frequency-dominated energy profile, whereas latent cross-attention exhibits sample- and species-specific spectral allocation. Overall, FLaG provides a transferable frequency-domain aggregation bias across protein, visual, and textual representations, with benefits that depend on the backbone and downstream task. Supplementary materials, source code, and data are available at https://www.healthinformaticslab.org/supp/ and https://github.com/Kewei2023/AMPCliff/tree/FLaG.

0.36

Multi-label versus multi-class classification of blood cells and their aggregates in microfluidic channels

cs.CV cs.LG ·2026-09-07 ·Igor Zingman, Shada Abuhattum, Sara Kaliman, Maximilian Schlögel, Paul Müller +6 more
similarity 0.43
Abstract · 26 pages, 5 figures

Deformability cytometry (DC) is a type of imaging flow cytometry, which uses a camera-equipped device to measure cellular stiffness in addition to other cellular properties at high throughput. Cellular properties such as area and elongation can identify cell types, but this requires prior knowledge of distinguishing properties and cannot be applied to clinically important cell aggregates. Using DC data, we evaluated conventional multi-class (MC) classification and introduced a multi-label (ML) approach for identifying blood cells and their aggregates. In particular, an ML classifier can simultaneously assign multiple cell-type labels to a single imaged event. We show that, unlike MC classification, ML classification can identify cell aggregates not represented in the training data. It also avoids the need for exhaustive, strictly defined aggregate labels, thereby simplifying and speeding up annotation. Since automated blood analyzers do not reliably analyze cell aggregates, our approach may help address this clinical gap.

0.32

Multi-Agent AI Design of a Nanowatt Biomedical Low-Pass Filter from Topology to Layout

cs.AR ·2026-10-19 ·Danial Noori Zadeh, Devanshu Prasad, Mohamed B. Elamien
similarity 0.43
Abstract · 5 pages, 5 Figures, 1 Table, Submitted to IEEE ISCAS 2027

We demonstrate a multi-agent framework that takes an analog circuit from topology synthesis to layout. A researcher agent directs schematic and layout agents, a four-tier memory stores the specification and lessons, and separate agents review the designs. Deterministic tools provide pass/fail simulation reports, symbolic analysis, graph-based netlist equivalence, parasitic injection, and extraction with DRC and LVS in every optimization trial. A human approves the specification and the layout plan. For a fourth-order, 250-Hz subthreshold biopotential low-pass filter, the researcher agent synthesized, through simulation-guided trial and error, a novel current-reuse architecture that shares a single dc bias branch between a super-source-follower biquad and a flipped-voltage-follower biquad. The agents completed a DRC- and LVS-clean layout in 130-nm IHP SG13G2 CMOS that meets the specification in nominal post-layout simulation, despite the noise-power trade-off and threshold-voltage sensitivity of subthreshold operation. The filter's input-referred noise over 0.5-200 Hz is 41.6% below that of the super-source-follower reference design at about equal core power.

0.23

OTTER - Two Transistor - One RRAM Architecture for Reliable In-Memory-Computing in 28 nm CMOS Technology

cs.ET ·2026-09-08 ·Yang Chen, Daniele Storelli, Xinyi Zhao, Ankit Bende, Paul-Philipp Manea +18 more
similarity 0.40
Abstract

This work presents OTTER, a 28 nm CMOS platform co-integrated with TaOx-based valence-change mechanism (VCM) RRAM, demonstrating a two-transistor-one-memristive-device (2T1R) architecture for reliable in-memory computing. The 2T1R cell combines a low-drive-current (LD) transistor and a high-drive-current (HD) transistor in parallel, providing dedicated bias paths for SET programming and RESET operation, respectively. Through systematic experimental and simulated comparison of various transistor-pairing configurations using the physical compact model JART VCM Rth, design guidelines for transistor sizing are derived, establishing the minimum RESET transistor W/L required for complete RESET as a function of the SET current compliance. The 2T1R cell is further characterized under pulse-based programming, demonstrating multilevel analog conductance tuning with narrow, well separated conductance states across six programmable levels. An analog content-addressable memory (aCAM) design based on the same 2T1R cell is additionally analyzed at the circuit level, evaluating trade-offs between top- and bottom-connected RRAM comparator configurations. A hardware implementation of compute-in-memory (CIM) multiply-and-accumulate (MAC) operations is further demonstrated on a 15 x 15 2T1R crossbar array.

0.29

Analog Pin Directionality as an Exfiltration Attack Surface in Mixed-Signal ICs

cs.CR cs.AR ·2026-09-16 ·Ramana Ranganatham, Chirag Adiga, Michael Zuzak, Tejasvi Das
similarity 0.40
Abstract · Submitted to IEEE Transactions on Information Forensics and Security (TIFS)

Mixed-signal SoCs rely on nominally input-only analog pins to acquire off-chip signals, but the directionality of these interfaces is generally treated as a functional property rather than explicitly verified as a security property. This work identifies and experimentally demonstrates a directionality-based class of analog and mixed-signal (AMS) exfiltration attacks in which data-dependent circuit-offset modulation converts a nominally input-only pin into an outbound information channel. We analytically model the attack mechanism and identify three enabling host conditions: a closed-loop amplifier, an exposed amplifier input, and sufficiently high impedance at that pin. This attack class is validated through a representative silicon case study using a photoplethysmography (PPG) analog front-end (AFE) fabricated in a commercial 55-nm CMOS process. The payload incurs $<$0.001\% area overhead relative to typical biosensing AFEs. Under the evaluated conditions, payload activation reduces the filtered PPG-output SNR by only 0.03~dB, while the maximum HT-induced perturbation of 5.9\% of the PPG amplitude remains within the 34.3\% benign variation at the exposed sensor-input pin across process and temperature. The raw exfiltration SINR remains below -20~dB, while targeted filtering increases it above 14~dB and enables signal recovery. Silicon measurements demonstrate data exfiltration through the input pin at bit rates up to 10~kbps and error-free recovery of a PRBS message. These results expose a conventional test-observability gap and establish analog pin directionality as an AMS security property requiring explicit verification, test coverage, and defense rather than being inferred from nominal signal flow.

0.30

S-ALSA: Co-Design of Adiabatic Logic-based Sensing and Balanced Bit-Cells for Secure and Energy-Efficient MRAM

cs.AR ·2026-09-27 ·Wu Yang, Amit Degada, Himanshu Thapliyal
similarity 0.40
Abstract · 6 pages; 2026 IEEE Computer Society Annual Symposium on VLSI, July 2026

Magnetoresistive Random Access Memory (MRAM) technologies such as Spin-Transfer Torque (STT-MRAM) and Spin-Orbit Torque assisted (SOT-STT-MRAM) offer nonvolatility and low leakage, making them attractive for IoT systems. However, conventional MRAM read circuits face two fundamental challenges: high dynamic energy consumption and vulnerability to side-channel attacks caused by data-dependent current variations in Magnetic Tunnel Junctions (MTJs). This paper presents a Secured Adiabatic Logic Sense Amplifier (SALSA) that addresses both challenges simultaneously through circuit-device co-design. S-ALSA combines structural current balancing via a 4T-2MTJ bit cell, which eliminates read current asymmetry at the storage level, with dynamic power equalization via adiabatic charge recovery in the sensing circuit. The proposed architecture supports both STT-MRAM and SOT-STT-MRAM. Case studies using 4x4 MRAM macros shows up to 80% energy savings over conventional Pre-Charge Sense Amplifiers (PCSA) across IoT frequencies. Correlation Power Analysis (CPA) attacks on PRESENT-80 encryption confirm complete suppression of key leakage when S-ALSA is combined with a balanced bit cell. This work establishes a unified framework where energy efficiency and hardware security are achieved simultaneously, enabling secure and low-power IoT memory design.

0.26

Data-Efficient and Interpretable Classification of Circulating Tumor Cell Phenotypes in Microfluidic Devices via Deep Learning

cs.LG ·2026-08-17 ·Serena Su, Yifan Wang, Senwei Liang
similarity 0.38
Abstract

Accurate classification of circulating tumor cell (CTC) phenotypes can provide valuable information for assessing metastatic potential. Label free microfluidic devices provide a hydrodynamic obstacle course that transforms subtle biophysical characteristics of CTCs, including size and deformability, into distinct kinematic trajectories. However, the highly nonlinear fluid structure interactions governing these trajectories make the inverse problem of inferring cellular phenotype from trajectory data analytically intractable. While deep neural networks (DNNs) have emerged as a powerful approach for addressing this inverse problem, their effectiveness is constrained by the limited availability of trajectory data and the lack of physical interpretability. To address these challenges, we propose an interpretable and data efficient DNN framework for trajectory based CTC classification. To mitigate the scarcity of data, we develop Subsequence (SubSeq), a targeted augmentation strategy that randomly extracts informative local trajectory segments during training to promote learning from localized patterns. We further apply Gradient Weighted Class Activation Mapping to identify the trajectory features and physical regions of the microfluidic device that drive model predictions. Experimental results demonstrate that SubSeq improves classification accuracy over the evaluated baseline and augmentation methods. Furthermore, interpretability analysis suggests that localized trajectory segments contain substantial biophysical information relevant to accurate classification. This provides justification for SubSeq and also highlights the redundancy of full-length trajectories. More broadly, the proposed framework views microfluidic geometries as physical encoders of cellular mechanical properties, providing mechanistic insights that may inform the future design of diagnostic devices.

0.47