CS Paper Radar

The Metrology Atlas: describing recorded physiological data as a measurement system, with VitalDB as a first application

Andrew J. Goodwin

eess.SP physics.med-ph ·submitted 2026-10-21 00:06 UTC · v1
datasetcode/data

Abstract

Every value in a recorded physiological dataset is a pair: a recorded time and a recorded value. Neither is the truth. The time comes from a clock that drifts and is corrected in jumps, and often describes a window that ended earlier. The value was quantised, rounded, sometimes heaped by hand, and measured by an instrument with its own error. We present the Metrology Atlas, a dataset-independent way of describing a recorded dataset as a measurement system, and its first application, to VitalDB, an open dataset of 6,388 surgical patients, as a proof of principle. For every variable, the atlas states what was measured, the measurement model linking it to the recorded pair, and what is known about the true time and true value given a record. Each part of the model carries its evidence: 69 studies, 49 parameters and 54 observations, each marked as measured, derived, estimated or assumed. The atlas maps 11 clocks and 14 devices into one timing network, and closes loops in that network to test its own model. Synchronisation reduces the median timing error between the EEG and ECG from 794 ms to 42 ms, and between ventilator and monitor waveforms from 378 ms to 55 ms. The atlas also documents data-quality issues, several of which correct the dataset's own documentation. It is published as a website and a single machine-readable file, with open-source code and a scheme of time-aware labels. Everything is open under CC BY 4.0 and MIT licences. The engine, schema and timing tools carry over unchanged, and the aim is to describe many other datasets the same way.

Comment
13 pages, 7 figures; companion website https://vitaldb.metrology-atlas.org

Closest papers

Nearest neighbours by meaning across the whole index.

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

cs.AI ·2026-10-21 ·Farouk Ganiyu Adewumi, Timothy Oladunni
similarity 0.59
Abstract

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

0.24

Physiological Trajectories and Observation Patterns in ICU Mortality Prediction: Transportability Under Changing Measurement Conditions

cs.LG q-bio.QM ·2026-10-30 ·Benjamin T. Pike
similarity 0.55
Abstract · 10 pages, 3 figures, 3 tables. Supplementary material available as an ancillary file

Objective: To distinguish the transferable predictive value of physiological trajectories from that of observation patterns in ICU mortality prediction, and to assess whether measurement timing affects performance independently of observation quantity. Materials and Methods: In-hospital mortality was predicted at 48 hours using MIMIC-III, MIMIC-IV, and eICU. Nested representations progressively integrated latest-value snapshots (R1), longitudinal physiological summaries (R2), and measurement frequency and timing features (R3). Models fitted on 7,762 MetaVision patients were evaluated on 21,682 MIMIC-IV patients and 43,878 eICU patients across 204 hospitals. The effect of measurement timing was assessed while holding the number of retained observations constant. Results: Physiological trajectories improved external prediction in eICU (R2-R1 log-loss difference -0.00922, 95% CI -0.01148 to -0.00704). Observation-pattern features improved locally developed eICU models (R3-R2 -0.00257, 95% CI -0.00370 to -0.00146), but not clearly after transfer from MetaVision (-0.00012, 95% CI -0.00206 to +0.00208). R3 was favoured in 10 of 30 source bootstrap refits. At matched observation counts, retaining measurements spread throughout the window reduced log loss relative to random retention by 0.03280 for R3 versus 0.00703 for R2. Removing the final 12 hours increased log loss relative to count-matched random removal by 0.01947 for R3 versus 0.00822 for R2. Under reduced availability, the local R3 increment changed from beneficial to harmful. Discussion: Physiological trajectories transferred more consistently, while observation-pattern features were particularly sensitive to the timing and availability of measurements. Conclusion: Clinical prediction models should be evaluated not only in new patient populations but also under the measurement conditions that supply their inputs.

0.27

Did the Grid Erase the Event? EndoClock for Auditing Medical World-Model Pipelines

cs.CV cs.LG ·2026-08-10 ·Yarin Udi, Tom Sharon-Shahak, Roee Masad, Dan Pri-Tal
published similarity 0.55
Abstract · Accepted for publication at the 1st MICCAI Workshop on Medical World Models (MWM 2026)

Medical world models commonly learn from multimodal recordings synchronized onto a fixed-rate grid. This preprocessing resamples each native stream onto a shared time axis. Each stream has an observation clock that governs when observations are emitted or updated. When this clock depends on the latent or acquisition state, it is endogenous. In such settings, synchronization may not be neutral and can erase task-relevant evidence before the model sees the data. We introduce a four-regime taxonomy that characterizes where the evidence needed to distinguish a target event or state survives. The relevant witness may remain in the sampled values, in grid-cell update patterns, in native timing, or only in an external acquisition channel. EndoClock operationalizes this taxonomy as a conservative pretraining audit. It reports the lowest witness-bearing representation supported by the available evidence, or unresolved when no regime can be established. We illustrate this failure in echocardiography, where B-mode video write-outs cease during pulsed-wave Doppler acquisition while the corresponding measurement events remain recorded only in an external acquisition log. This work is a preliminary failure alert and executable audit. Its practical message is to preserve the native observation process long enough to determine whether synchronization has erased information required by the intended task.

0.18

Large language models in medical time series analysis

eess.SP cs.AIcs.LG ·2026-09-07 ·Yu Han, Cigdem Beyan, Xiang Zhang, Xiaofeng Liu, Nan Liu +4 more
code/data similarity 0.54
Abstract

Medical time series (MedTS), including electrocardiograms (ECG), electroencephalograms (EEG), photoplethysmography (PPG), and vital-sign recordings, are central to clinical diagnosis and health monitoring. As large language models (LLMs) have advanced, a growing body of work has examined how their reasoning, generation, and knowledge-integration capabilities can support MedTS analysis. Yet existing studies remain scattered, and the field still lacks a clear view of how these models should be designed, integrated into clinical workflows, and evaluated. This review synthesizes recent work on large language models for medical time series analysis (MedTSLLMs), covering both methodological progress and issues related to real-world deployment. We review model architectures, data resources, and processing pipelines, and prompt design strategies adapted for diverse clinical scenarios. We further organize existing MedTS applications, ranging from diagnostic interpretation and report generation to longitudinal health monitoring and physiological signal synthesis, highlighting task-specific design choices, common evaluation protocols, and empirical findings reported across studies. By bringing together current practices and open challenges, this review aims to provide a clearer foundation for developing, evaluating, and deploying MedTSLLMs responsibly in healthcare. We also maintain a regularly updated list of MedTSLLM studies and resources at: https://github.com/hy727/MedTSLLM-Review.

0.34

ECG-Scroll: A Long-Horizon, Streaming Benchmark and Agent Environment for Interpretation of Ambulatory Electrocardiograms

cs.LG cs.AIcs.CLeess.SP ·2026-09-27 ·Haitao Li, Chenglin Li, Zhengyao Ding, Ziyu Li, Yiheng Mao +1 more
benchmark similarity 0.54
Abstract

Multimodal large language models (MLLMs) can now interpret a standard ten-second, twelve-lead electrocardiogram (ECG) with clinically grounded, reward-verified reasoning. Real cardiac monitoring is different. Ambulatory (Holter) and telemetry recordings span hours to days and are read as they stream in, and their clinically decisive findings are paroxysmal, brief episodes buried in an otherwise unremarkable trace. Such a recording cannot be held in one context at diagnostic resolution, and its future has not yet happened, so a reader must work online, deciding what to measure now, committing evidence to memory as it passes, and reporting events as they occur. We recast long-duration ECG interpretation as a long-horizon, online (streaming, causal) sequential decision process and introduce ECG-Scroll. As a benchmark, long ambulatory recordings are streamed to an agent chunk by chunk, and it must localize, quantify, and promptly flag paroxysmal events without access to future signal; because the underlying signal is retained, every answer is checkable against objective ground truth, giving rule-based rather than judge-based rewards, and the streaming formulation adds a metric batch evaluation cannot express, the detection latency between an event's onset and the moment the agent records it. As an agent environment, it is a fixed, gym-style interaction layer that exercises three competencies single-glance ECG models never touch: Memory, Tool use through signal-grounded measurement rather than reading pixels, and Planning of what to measure now and when to commit. We release 390 whole-recording instances spanning 2,536 hours of two-lead ambulatory ECG and evaluate a signal-threshold rule agent alongside off-the-shelf LLM agents online, characterizing how they use memory, tools, and planning and where the benchmark's head-room lies.

0.08

PGP-Clinical-TimeKAN: Prior-Guided Joint Probabilistic Forecasting of Clinical Trajectories

cs.AI ·2026-08-24 ·Weizhi Nie, Rihao Chang, Weijie Wang, Yuting Su
similarity 0.53
Abstract · 30 pages, 12 figures, and 17 tables

Clinical deterioration unfolds through coupled, partially observed trajectories, not a single diagnostic label. We introduce PGP-Clinical-TimeKAN, a trajectory-first framework for joint probabilistic forecasting of multivariate physiology. It combines missingness-aware temporal encoders, a soft organ-system prior, patient-specific relations, nonlinear Kolmogorov-Arnold messages, and a low-rank multivariate Student-t head. We evaluate 24-hour histories and six-hour forecasts on a frozen MIMIC-IV-derived cohort of 6,882 patients and 54,694 windows. Across five seeds and 13 models, PGP-Clinical-TimeKAN obtains the second-lowest normalized MAE (0.37727 +/- 0.00029) and the lowest RMSE (0.52656 +/- 0.00034). It reduces MAE by 0.52% relative to deterministic TimeKAN. For probabilistic forecasting, it reaches a marginal NLL of 0.66380 and a CRPS of 0.27301. Empirical coverage is 0.533, 0.831, and 0.958 for nominal 50%, 80%, and 95% intervals. Removing relational structure causes the largest ablation loss. Increasing covariance rank improves joint likelihood but has little effect on point accuracy. A trajectory-derived risk score remains weaker than a dedicated GRU-D classifier (AUROC 0.603 versus 0.650), which limits the present clinical claim. Joint trajectory forecasting therefore provides an inspectable intermediate task, but accurate physiology forecasts alone do not ensure a calibrated event detector.

0.15

When2What: A Timing-Conditioned Framework for Long-Horizon Forecasting of Continuous Cardiovascular Waveforms

cs.LG ·2026-11-06 ·Chaoqi Zhang, Shujie Yan, Zhao Zhang, Yanhua Sun, Yu Wang +4 more
code/data similarity 0.53
Abstract · 31 pages (18 pages main text, 13 pages supplementary material), 7 figures, 31 tables. Code available at https://github.com/prncoprs/when2wha…

Long-horizon forecasting of quasi-periodic cardiovascular waveforms, such as the electrocardiogram (ECG), arterial blood pressure (ABP), and photoplethysmogram (PPG), requires predicting both when future cardiac events will occur (beat timing) and what the local structural pattern looks like around each event (beat morphology). However, standard sequence forecasters trained with pointwise mean squared error (MSE) average across uncertain future heartbeat phases, flattening sharp R peaks and pulse upstrokes into featureless baselines. Our analysis of intraoperative ECG reveals a clear temporal asymmetry: beat-time predictability from history decays within seconds due to stochastic heart-rate variability, whereas local beat morphology aligned at true beat times remains stable over several minutes. Guided by this insight, we introduce When2What, a timing-conditioned framework comprising three stages: Predict, Commit, and Generate. Given a 120-s history, When2What predicts a dense 60-s timing map, selects and sharpens discrete beat events into unit-height Gaussian impulses, and conditions a neural waveform generator on both these committed events and the observed history. Across intraoperative ECG, When2What substantially outperforms existing time-series and physiological forecasters, achieving a near-term waveform event skill of 0.644 and reproducing 95.62% of its predicted heartbeats in the generated waveform where direct long-horizon forecasters collapse into flat baselines. Furthermore, When2What transfers zero-shot to external hospital and atrial fibrillation cohorts, extends effectively to ABP and PPG pulse waveforms, and is supported by ablations and synthetic analyses that establish explicit timing conditioning as an effective paradigm for quasi-periodic long-horizon waveform forecasting.

0.24

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.52
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08