CS Paper Radar

Recovering Plausible Transmission Outage Scenarios

Karen Ji, Cameron Khanpour, Samuel Talkington, J. Kyle Skolfield, Daniel K. Molzahn

eess.SY math.OC ·submitted 2026-10-21 15:25 UTC · v1

Abstract

Expansion planning for extreme weather needs outage scenarios that specify which transmission branches fail. However, public outage records often only report customers without power by county, making it unclear how to exploit this information to create outage scenarios. We propose a method to recover sets of outaged branches that most closely match regional load shed data. This gives us sets of plausible outages for a given hazard event. We formulate a bilevel problem with a load shedding DC optimal power flow in the lower level. We relax the binary branch states to differentiate the lower level problem, replace it with its sensitivity matrix, and use gradient descent to update the upper level. We treat the relaxed branch states as probabilities and perform randomized rounding to restore integrality. On three test systems with synthetic outages, the recovered sets reduce the load shed error to $0.02-4.5\%$. On the California Test System with storm data from December 2025, the error falls to $23\%$. These scenarios give expansion planning a reliable source of outage data tied to observed hazards.

Closest papers

Nearest neighbours by meaning across the whole index.

OutageDiT: A Foundation Model for Power Outage Forecasting and Scenario Generation

cs.LG cs.AI ·2026-09-01 ·Yunqin Zhu, Feng Qiu, Yao Xie
published similarity 0.63
Abstract · 11 pages, 3 figures, 3 tables. Accepted at the NeurIPS 2026 Second Workshop on MLxOR

Power-outage planning requires scenarios before an event occurs. These scenarios must represent uncertainty in magnitude, timing, and duration while preserving temporal dependence. However, severe events are rare, and data from any single region contain few examples of extreme outage and restoration patterns. To address this challenge, we introduce OutageDiT, a foundation model for generating seven-day outage trajectories at 15-minute resolution, trained on outage and weather records across the United States. Specifically, a condition encoder processes historical context and known future covariates once per forecast, and a shallow flow-matching decoder reuses the resulting horizon-aligned states to sample complete outage trajectories. This enables point forecasting, uncertainty quantification, and conditional scenario generation within one deep generative model. Across outage forecasting benchmarks, OutageDiT improves forecast accuracy and scenario quality over strong baselines and supports zero-shot transfer to held-out regions. Together, these results position conditional outage scenario generation as a bridge from outage forecasting to operational planning under uncertainty.

0.26

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.61
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Learned Control Variates for Rare Grid-Outage Estimation at Electric Vehicle Charging Stations

cs.AI cs.CEeess.SYstat.ML ·2026-10-19 ·Sulyman Iyanda, Mansur Arief
similarity 0.61
Abstract

Public charging of electric vehicles (EVs) adds a large and synchronized load to the distribution feeders. In most networks, it is rare to overload a feeder at the same time. When it does happen, the consequences can be severe: an overloaded feeder stresses its transformers and can trigger cascading outages across a city. Planners who design for high reliability therefore need to estimate very small outage probabilities. To that end, plain Monte Carlo estimation with an expensive grid simulator can require a prohibitively large number of runs for this task. To reduce the number of runs, we propose a control variate (CV) built from a learned classifier of the outage, trained on cheap observable features such as temperature and load forecasts. We show that for any binary learner, the variance reduction is an explicit function of its recall and false-positive rate. Furthermore, we show that control variate based on a Gaussian proxy of the load loses its effect as outages become rarer, while a learner with non-vanishing precision keeps removing a fixed fraction of the variance even in the extreme rare-event regime. We verify these results in numerical experiments using a feeder-overload simulator across three orders of magnitude of outage probability and obtain that even weak learner with a single feature can remove a quarter of the variance, while a boosted-tree learner is able to remove about 60%. We then apply the estimator to the feeder network of Surabaya, Indonesia, in which the Gaussian load model leaves every feeder three to seven times the one-day-in-ten-years blackout target. At the same simulation budget, planning the reserve with the learned CV and a 95% confidence limit reduces the city-wide blackout days by a third compared with Monte Carlo. These results show that learned control variates can help planners design distribution grids that stay reliable against rare outages.

0.20

Long-Term Operational Planning Using Scenario-Based System Load Forecasting

cs.CR ·2026-09-28 ·Akash Debnath, Shiuli Subhra Ghosh, Jaime De La Ree, Alex Freeman, Kavin D Jones
similarity 0.60
Abstract

The rapid expansion of hyperscale data centers is significantly increasing electricity demand in Northern Virginia. Dominion Energy, the region's primary electric utility, must reinforce its transmission network to support this growth. These projects require planned outages that must be evaluated months in advance to support construction planning and outage coordination while meeting NERC and PJM N-1 reliability requirements. Long-term outage studies are commonly performed day by day using monthly or seasonal peak-load assumptions. Although this approach simplifies analysis, it can be overly conservative because it does not capture granular load variability. Consequently, short-duration outages that may be feasible under realistic loading conditions are often postponed or denied, delaying critical transmission expansion and grid modernization projects. This paper evaluates the operational value of incorporating realistic multigranular load forecasts into long-term, contingency-based outage assessments and compares the results with conventional peak-based methods. Daily, weekly, and monthly forecasts are developed using statistical and machine-learning models, including SARIMA, Prophet, Gradient Boosting, and Random Forest, followed by bottom-up temporal reconciliation to maintain consistency across forecast horizons. Results show that granular load forecasts reduce unnecessary conservatism and improve outage accommodation, particularly for short-duration requests, without changing existing reliability criteria. The proposed approach can strengthen long-term outage coordination and support timely transmission reinforcement and grid modernization.

0.20

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.58
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24

Critical Weather Scenario Screening Using Weather-to-Voltage (W2V) Predictive Modeling

eess.SY ·2026-08-24 ·Sol Lim, Min-Seung Ko, Hao Zhu
published similarity 0.58
Abstract · 6 pages, 2 figures. Accepted to IEEE SmartGridComm 2026

This paper proposes a critical weather scenario screening framework for identifying weather conditions that can trigger high-voltage (HV) events in the power grid. Unlike conventional weather-aware contingency analysis limited to component-level outage risk, our framework screens weather scenarios as potential drivers of grid-level voltage violations. Given a non-critical weather scenario, we seek the perturbation over the high-dimensional weather space to maximize a pre-defined voltage criticality score, by using a differentiable weather-to-voltage (W2V) predictive model to facilitate the gradient update over a compact latent space. Specifically, a non-negativity constraint is used for achieving physically-consistent perturbations, with another L1-norm based constraint for bounded perturbation. The latter could promote sparse and interpretable perturbations, and this uniform budget also yields a sensitivity-aware vulnerability ranking across different weather scenarios. Numerical experiments on a 6717-bus synthetic Texas system have effectively demonstrated the potential of weather uncertainty in triggering HV events, and this potential cannot be represented by the voltage analysis of individual weather scenarios. Interestingly, the most vulnerable scenarios are characterized by wind-dominated perturbation patterns concentrated in high wind-capacity regions, coinciding with observations from actual power flow data and experiences in real system operations.

0.40

Minimum Bounding Sets for N-1-1 Branch Contingencies Under Thermal and Voltage Limits in Linear Network Models

eess.SY ·2026-10-08 ·Timothy N. Thacker
similarity 0.58
Abstract · 10 pages, 4 figures

N-1-1 contingency analysis studies the loss of one element followed by system adjustments and the loss of a second. The number of contingency pairs increases quadratically with the number of applicable elements, and traditional ranking-based screening methods cannot guarantee that omitted pairs are bounded. This paper determines the minimum bounding set of two-branch-outage pairs: the smallest set that can reproduce the worst value of every violated thermal and voltage limit of a linear network model. In the DC model, effects of an outage pair can be quantified by the extent of the coupling between the outages. The paper measures this by the cosine between the two outages in the network's cycle space, with a bound that splits into one term per outage and is within a near-ideal factor of $\sqrt{1+\varepsilon}$. This argument extends to every linear model in which an outage subtracts a positive semi-definite low-rank term from a symmetric positive definite matrix, with a tight bound and a collapse test. A model with voltage magnitudes is extracted by performing one Newton step on the energy function of the lossless network in rectangular coordinates. A best-first search built on these bounds reproduced brute force on public systems of up to 2{,}869 buses with 130 to 3{,}800 times fewer pair evaluations for flows and 170 to 23{,}700 times fewer for voltages. Gaps in translation to nonlinear models are explored on the IEEE 118-bus system.

0.26

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.57
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34