CS Paper Radar

An Agent Architecture with Tools and Memory for Selective Correction of Wrist PPG Heart Rate Estimates

Xu Wang, Shuhan Yi, Zhen Cheng

cs.LG ·submitted 2026-10-22 03:59 UTC · v1

Abstract

Wrist photoplethysmography (PPG) heart rate estimates are vulnerable to motion artifacts, and corrections that reduce mean error can worsen individual windows. We propose an agent architecture with tools and memory around a fixed heart rate estimator. Pulse, motion, and limited historical evidence generate candidate estimates, whose predicted benefits and harms guide selection. An independent risk gate determines whether to retain, correct, or reject each output. We trained the architecture on PPG-DaLiA and tested it on Wrist Exercise, GalaxyPPG, and WildPPG with frozen weights. Across these four public datasets, mean absolute error (MAE), macro-averaged over ten estimators, decreased by up to 44.5%, with the largest reduction on GalaxyPPG. Beneficial and harmful corrections decreased and increased absolute error by more than 1 bpm, respectively. Their ten-estimator macro-averaged proportions ranged from 16.06% to 36.64% and from 1.68% to 6.77%, respectively, across the four datasets. At 60% and 80% target coverage, numerical correction on the same accepted windows contributed more to total error reduction than window selection. We implemented real-time wearable acquisition, Bluetooth reception, and smartphone deployment of a selected estimator and the framework. In backend analysis of four prototype recordings from one participant, ten-estimator macro-averaged MAE decreased from 9.09 to 4.45 bpm without additional rejection. Under the evaluated conditions, the architecture improved average accuracy while quantifying correction benefits and harms, supporting wearable heart rate analysis that considers error, correction risk, and coverage.

Comment
71 pages, including 48 pages of Supplementary Information

Closest papers

Nearest neighbours by meaning across the whole index.

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.62
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.60
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

StrokeGuard: A Multi-Agent Guided System for Prehospital Stroke Assessment

cs.HC cs.AIcs.MA ·2026-08-25 ·Wentao Yang, Zhenye Xu, Ruoyi Li, Musen Zhang, Yao Guo
similarity 0.58
Abstract

Prehospital stroke assessment aims to accurately identify stroke symptoms and make rapid decisions through standardized procedures within an extremely narrow time window, thereby saving valuable time for subsequent treatment. In clinical practice, FAST-based scales are widely used for prehospital stroke assessment by issuing instructions that guide subjects to perform specific actions to screen facial, arm, and speech functions. However, in home and community settings, non-clinical users often encounter challenges such as inaccurate descriptions, incomplete symptom observation, and difficult operational procedures, which may lead to inaccurate or biased assessment results. To address these challenges, this paper presents StrokeGuard: a multi-agent guided system designed for prehospital stroke assessment that makes mobile FAST screening more standardized and executable. Specifically, to overcome the limitations of traditional single-agent systems in terms of procedural fault tolerance and user guidance capability, StrokeGuard adopts a dual-channel agent mechanism that separates formal assessment (i.e., facial palsy, arm weakness, speech impairment) from procedural support (e.g., step prompts, error correction, and real-time feedback). It guides the assessment process through multi-agent collaboration, dual-channel interaction, state-machine control, and stage-local fallback recovery mechanisms. Stage-specific scoring is delegated to constrained pretrained video assessment modules, while evidence source records are integrated with structured report generation. The user evaluation uses MATES-9, an exploratory scale for measuring user experience in multistep AI-guided tasks. In a simulated prehospital scenario, StrokeGuard improves the MATES-9 total score over a paper FAST-style form by 10.83 points, corresponding to a 23.8% relative increase.

0.21

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

cs.RO cs.LGeess.SP ·2026-11-14 ·Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong
similarity 0.56
Abstract · 8 pages, 5 figures, 3 tables. Submitted to IEEE Robotics and Automation Letters (RA-L)

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

0.23

Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors

eess.SP ·2026-10-27 ·Elisabetta De Giovanni, Iñigo Urteaga, Matteo Croci, Tomas Teijeiro
publishedbenchmark similarity 0.56
Abstract · Accepted and presented at 53rd Computing in Cardiology conference in Madrid, Spain on 20th - 23rd September 2026

PPG is the main technology for wearable heart rate (HR) monitoring. However, motion artifacts during intense physical activity reduce its reliability due to spectral overlap with the cardiac signal. This study investigates whether severely contaminated PPG signals can yield reliable HR estimates without auxiliary sensors by leveraging prior knowledge of HR dynamics. We acquired simultaneous PPG and ECG signals from 21 subjects during a maximal cycloergometer test. Using Leave-One-Subject-Out cross-validation, we built HR evolution priors from the ground-truth ECG and applied Dynamic Time Warping (DTW) to align normalized HR curves and estimate a barycenter average. DTW aligns normalized HR curves with minimal error across all subjects, validating robust population-based priors. For each test subject, we combined the PPG Power Spectral Density (PSD) with the prior distribution to generate a "posterior PSD". We identified and ranked candidate HR trajectories using heuristic search within the "posterior PSD" and selected the most likely path. Our approach reduced mean absolute error (MAE) in BPM relative to the ground-truth ECG by a median of 63.3% (IQR: 47.3%-74.6%) compared to a PPG+accelerometer benchmark. These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.

0.30

Deep Learning for Sleep Heart Rate Estimation from Accelerometers: Toward Population-Scale Cardiac Insight Without Optical Sensors

cs.LG cs.AI ·2026-10-05 ·Tanbin Islam Rohan, Pranjol Sen Gupta, Tanusree Debi, Nazmus Sakib
similarity 0.55
Abstract · 8 pages, submitted in BHI 2026

Large longitudinal cohorts often contain wrist accelerometry without optical heart-rate sensing, motivating recovery of cardiac information from motion signals already collected during sleep. We present SeqSmoother, a transformer-based temporal corrector for sleep heart rate (HR) estimation from wrist accelerometry. SeqSmoother combines spectral descriptors with an intermediate Nightbeat-derived frequency anchor and a physics-motivated sub-harmonic feature designed to identify harmonic frequency lock-on. All inference-time features are derived from wrist accelerometry, while ECG is used only to construct reference HR labels and training-label quality weights. We evaluate SeqSmoother using 13 participant-disjoint held-out folds and compare it with the official Nightbeat implementation under a matched 60-s window and 15-s step protocol. Across all out-of-fold predictions, SeqSmoother achieved a participant-macro MAE of 1.60 bpm. On Nightbeat-retained matched intervals, Nightbeat achieved lower absolute error than SeqSmoother (0.615 versus 1.091 bpm), while SeqSmoother provided estimates over a larger portion of the eligible recording; Nightbeat produced final estimates for 72.85% of the SeqSmoother-eligible out-of-fold grid. Separately, the proposed sub-harmonic ratio achieved an AUROC of 0.972 for identifying reference-defined harmonic lock-on candidates. These findings reveal an accuracy-availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.

0.32

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring

eess.SP ·2026-10-29 ·Hongda Huang, Xiao Peng, Xiaoyu Li, Shuailong Tang, Guangpu Zhu +4 more
published similarity 0.55
Abstract · Accepted by the 2026 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI 2026)

Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.

0.25

When Temporal Perturbations Act Like Sensor Biases: Label-Free Auditing of Wearable Activity Recognizers

cs.LG cs.AIcs.CR ·2026-09-24 ·Qingyu Wu, Yuan Wei, Renju Liu, Hua Cheng
similarity 0.55
Abstract

Wearable human-activity recognition (HAR) models operate across sensors, subjects, and backbones, yet a smooth waveform may appear temporal while exploiting a persistent sensor offset primarily. We introduce SpectrumAudit, a label-sealed audit that fits a phase-randomized full-window stimulus on calibration windows from subjects held out from training and testing. After selection, it replays its exact DC projection and budget-constrained zero-mean residual on the same frozen victim without refitting. Across 27 victims from three datasets and three backbones, the selected waveforms cause 2.87-40.83-point three-phase robust accuracy losses. Under this replay budget, DC is more damaging than AC on 24/27 victims and recovers at least 90% of the full drop on 22/27; all 5 failures occur on WISDM. In a held-out UTD-MHAD check, the selected waveform causes 13.49-pp accuracy and 11.68-pp macro-F1 losses, versus -0.66 pp for matched random changes. The audit diagnoses offset versus zero-mean variation under a common peak-budget cap. The code will be released upon acceptance.

0.34