CS Paper Radar

Solid State Transformer - Next Generation MV Interface for Native DC loads

Steffan Hansen, Marco Liserre, Mohamed Moharram

eess.SY ·submitted 2026-10-23 09:51 UTC · v1

Abstract

About PowerNexa PowerNexa is the project name for a start- up initiative driven by Marco Liserre and Steffan Hansen with the ambition to develop the next generation power grid interface. Battery integration and DC loads Ongoing electrification is fundamentally changing how electrical energy is produced and consumed. DC loads are becoming an integral part of the infrastructure while battery integration is increasingly needed to manage peak demand and address grid capacity constraints. The next generation grid interface PowerNexa aims to combine a fully controllable Medium Voltage grid interface with native battery integration and multiple DC voltage levels, based on an architecture designed for high efficiency, modularity and redundancy.

Comment
8 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

A Critical Review of Grid Integration Challenges and Flexibility Opportunities for Large-Scale Data Centers

eess.SY ·2026-10-14 ·Bibek Dhakal, Manohar Chamana, Biswambhar Gayen, Jatendar Kumar, S M Shams Rahman +5 more
similarity 0.55
Abstract

The rapid proliferation of cloud computing and artificial intelligence workloads is fundamentally reshaping the magnitude, spatial concentration, and electrical characteristics of data center power demand. Data centers differ from conventional commercial loads because they combine high rack densities, converter-dominated interfaces, thermally coupled cooling, uninterruptible power supplies, programmable workloads, and increasingly complex behind-the-meter generation and storage within a single facility. This review examines their grid integration from utility and sustainable-energy perspectives across resource planning, large-load interconnection, distribution feeders, market operation, real-time dynamics, power quality, and asset management. Particular attention is given to distribution-level issues that receive limited treatment in broader energy reviews: bidirectional operation on renewable-rich feeders, harmonic propagation and resonance, ride-through and reconnection, transformer derating, cable ampacity, neutral-conductor heating, protection, and measurement. Static, composite, physics-based dynamic, calibrated, impedance, electromagnetic transient, and hybrid load models are compared according to study purpose and data requirements, and utility coordination platforms, uninterruptible power supply and battery control, workload flexibility, renewable co-location, cogeneration, fuel cells, thermal storage, and clean firm supply are assessed. The central finding is that requested peak demand and annual energy matching alone cannot establish reliable or sustainable integration. Credible assessment must consider hourly and locational supply, network deliverability, marginal emissions, lifecycle and water impacts, backup obligations, rebound, asset health, and verified operating capability.

0.12

From Grid to Chip: Power Architecture, Stability, and Flexibility of AI Data Centers

cs.ET cs.AReess.SY ·2026-09-10 ·Yubo Song, Rui Kong, Takuro Umihara, Pooya Davari, Frede Blaabjerg +1 more
hot direction similarity 0.54
Abstract · The manuscript has been submitted for review to IEEE Open Journal of Power Electronics

The rapid growth of artificial intelligence (AI) computing is transforming data centers into large, dynamic electrical loads. Their deployment is primarily constrained by energy availability and grid-connection capacity, which is further aggravated by the ability of power-delivery architectures, control systems, and computing workloads to operate reliably during fast grid disturbances. This article presents a technological perspective on AI data centers as grid-interactive computing systems. First, it reviews grid-integration bottlenecks, evolving connection policies, grid-code requirements, which has fostered new technological trends via spatio-temporal flexibility available through workload orchestration, cooling systems, on-site resources, and energy storage. Second, it maps the evolution of power-delivery architectures from medium-voltage grid interfaces to chip-level, discussing higher-voltage DC distribution, solid-state transformers, wide-bandgap devices, advanced chip-level power delivery, and liquid cooling. Third, it establishes a three-level stability framework spanning rack-level DC-bus dynamics, facility-level converter interactions, and system-level grid-coupled behavior. The framework connects dominant instability mechanisms, including constant power load effects, impedance interactions, forced oscillations, and operating-mode transitions, with suitable modeling, assessment, and mitigation approaches. Synthesizing these topics, this article highlights grid-to-chip co-design as a central requirement for scalable AI infrastructure, linking computing workloads, power-delivery systems, energy buffers, and grid operation.

0.27

An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

eess.SY ·2026-11-06 ·Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang
similarity 0.53
Abstract · 13 pages, 19 figures. Submitted to IEEE for possible publication

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

0.40

Supporting Data Center Grid Integration via Co-Optimized Battery Energy Storage Sizing and Capacity Allocation

eess.SY math.OC ·2026-11-06 ·Wei Wang, Himanshu Sharma, Thiagarajan Ramachandran
similarity 0.52
Abstract

Interconnecting large data centers can be delayed by grid requirements on demand flexibility, ramping limits, and ride-through performance. This paper proposes an optimization-based framework to size a Battery Energy Storage System (BESS) that accelerates data center grid integration by providing BESS capacity required to meet selected flexibility and grid-support requirements. The model co-optimizes BESS power rating and energy capacity while allocating capability across three services: (i) demand response over a specified duration, (ii) mitigation of high-magnitude, high-frequency load fluctuations through reserved active power with zero net state-of-charge change, and (iii) voltage support via reactive power capability at the point of common coupling. Minute-level operational scheduling enforces state-of-charge feasibility and load ramp constraints, and incorporates a controllable queue of delay-insensitive computing tasks to enhance flexibility. A case study using a real data center load profile demonstrates the proposed method and quantifies the BESS power-energy requirements and operational trade-offs needed to satisfy the multi-service constraints, providing practical guidance for interconnection planning and deployment.

0.05

Scalable Reference Electrical Architectures for Modern Data Centers

eess.SY ·2026-11-11 ·Kiran Kumar Challa, Yan, Zhou, Kumarsinh Jhala
benchmarkhot direction similarity 0.51
Abstract · 5 pages, 3 figures, conference article

The rapid growth of cloud computing, artificial intelligence (AI), and high-performance computing is driving the deployment of data centers with electrical demands ranging from tens of megawatts to multi-gigawatt campuses, creating significant challenges for utility interconnection and power system planning. This paper presents scalable, vendor-neutral reference electrical architectures for colocation, hyperscale, and AI data centers. The proposed framework integrates modular Power PODs, hierarchical HV/MV/LV distribution, standby generation, uninterruptible power supplies (UPS), battery energy storage systems (BESS), and scalable utility interfaces into a unified planning methodology. Three representative Power POD configurations are developed to support systematic capacity expansion while maintaining consistent electrical topology and equipment sizing. The proposed architectures facilitate utility interconnection studies, equipment demand forecasting, transmission planning, and grid infrastructure assessment, providing an open and reproducible benchmark for evaluating the impacts of large-scale data center deployment on future power systems.

0.31

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.51
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36

Beyond Tomorrow -- Electrification of Hard-to-Abate Sectors

eess.SY ·2026-09-28 ·Jonas Huber, Johann W. Kolar
similarity 0.50
Abstract · Submitted to IEEE magazine

Reaching net-zero greenhouse-gas (GHG) emissions requires deep electrification beyond ground transportation, buildings, and conventional industry automation. This article discusses direct electrification pathways for hard-to-abate sectors, which today account for 30% of global GHG emissions and include steel, cement, chemicals, aviation, and shipping. Whereas indirect electrification via hydrogen and synthetic fuels will remain indispensable for some applications, direct use of electricity is generally preferable from an efficiency perspective. We review selected emerging opportunities for power electronics in industrial process electrification, including steelmaking through hydrogen plasma smelting reduction or molten-oxide electrolysis, electrified cement production, high-temperature process heat, plasma-assisted chemistry, and electrochemical synthesis. Across these examples, power converters must interface with highly application-specific loads, ranging from low-voltage high-current electrolysis cells to dynamic plasma reactors and megawatt-scale induction heating systems. In addition, high-power grid interfaces and in-plant energy management/buffering solutions must be clarified. Thus, future electrified industrial processes open new "beyond-tomorrow" research challenges for power electronics in close interdisciplinary collaboration with scientists from neighboring disciplines.

0.26

Coordinated Conservation Voltage Reduction and Network Topology Reconfiguration in Active Distribution Networks

eess.SY ·2026-10-12 ·Rida Fatima, Hassan Zahid Butt, Xingpeng Li
similarity 0.49
Abstract

Distribution networks rely on conservation voltage reduction (CVR) and network topology reconfiguration (NTR) to manage demand, distributed energy resources (DERs), and tighter operating margins. Yet these strategies are typically deployed independently, despite coupled effects on feeder voltages, losses, and loading. This paper addresses that gap by developing a day-ahead mixed-integer second order cone programming (MISOCP) framework that jointly optimizes feeder head voltage control and network reconfiguration. The formulation incorporates AC branch flow constraints, ZIP load models, DERs, battery energy storage systems, and multi substation radiality. Using modified IEEE 33 bus and 123 bus systems, four configurations isolate the individual and coordinated effects of CVR and NTR. On the 33-bus system under mixed ZIP loading, NTR reduces active energy loss by 2.50%, while coordinated operation reduces it by 2.91% relative to SDN and produces a 2.46% CVR induced active load reduction relative to SDNTR. Under constant impedance loading, coordinated operation reduces active energy loss by 17.65% relative to SDN, while CVR reduces active load by 14.61% relative to SDNTR. DER portfolio scaling shows a nonmonotonic coordinated load reduction response, strongest at 20% penetration and decreasing at higher levels. On the 123 bus system, NTR reduces losses by 19.3%, while CVR reduces voltage dependent load energy by 2.3 to 2.4%. Under loading stress, SDN becomes infeasible at 120% loading, whereas CEDNTR remains feasible. Overall, the results demonstrate complementary, operating condition dependent benefits shaped by load composition, DER portfolio scaling, feeder topology, voltage margins, and source constraints, highlighting the value of joint optimization.

0.29