An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang

eess.SY ·submitted 2026-11-06 10:56 UTC · v1

Abstract

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

Comment
13 pages, 19 figures. Submitted to IEEE for possible publication

Closest papers

Nearest neighbours by meaning across the whole index.

DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

eess.SY ·2026-11-06 ·Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang
unusual similarity 0.64
Abstract · Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

0.38

Steady-State Equivalent Circuit Model for Data Center Loads

eess.SY ·2026-08-18 ·Muhammad Hamza Ali, Peng Sang, Hyeon Woo, Hyein Kang, Sungyun Choi +1 more
similarity 0.56
Abstract

Planners currently represent data centers as aggregate constant-PQ or ZIP loads in steady-state interconnection and contingency studies. These aggregate models are computationally convenient. However, they obscure the electrical relationship between computational workloads, server utilization, and grid-side demand. They ignore the internal power-electronic conversion stages of IT loads and assume homogeneous workload distributions across the compute clusters. This hides operating-point-dependent converter losses and efficiency variations. We propose a steady-state equivalent-circuit model (ECM) for data centers, which explicitly builds circuit models for IT loads, power supply units, cooling, and auxiliary systems. For power supply units, the equivalent circuit model explicitly represents internal power-electronic conversion stages. For IT loads, we develop a utilization-dependent server power model, and we combine it with loss-aware ECMs of power supply units. This approach captures the grid-side impact of heterogeneous workload distributions while preserving compatibility with conventional power-flow analysis. We evaluate this data center ECM in large-scale transmission power flows, using Monte Carlo simulations under heterogeneous and homogeneous cluster utilization. In comparison with the fixed-efficiency constant-PQ model, the ECM predicts that the most stressed line exceeds its thermal limit in about 30% of Monte Carlo samples. The results further show that homogeneous server utilization overstates line-loading variability by 17%-46% relative to heterogeneous server utilization, depending on the intra-cluster workload correlation.

0.47

Solid State Transformer - Next Generation MV Interface for Native DC loads

eess.SY ·2026-10-23 ·Steffan Hansen, Marco Liserre, Mohamed Moharram
similarity 0.53
Abstract · 8 pages, 5 figures

About PowerNexa PowerNexa is the project name for a start- up initiative driven by Marco Liserre and Steffan Hansen with the ambition to develop the next generation power grid interface. Battery integration and DC loads Ongoing electrification is fundamentally changing how electrical energy is produced and consumed. DC loads are becoming an integral part of the infrastructure while battery integration is increasingly needed to manage peak demand and address grid capacity constraints. The next generation grid interface PowerNexa aims to combine a fully controllable Medium Voltage grid interface with native battery integration and multiple DC voltage levels, based on an architecture designed for high efficiency, modularity and redundancy.

0.27

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.53
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.53
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

Coordinated Conservation Voltage Reduction and Network Topology Reconfiguration in Active Distribution Networks

eess.SY ·2026-10-12 ·Rida Fatima, Hassan Zahid Butt, Xingpeng Li
similarity 0.52
Abstract

Distribution networks rely on conservation voltage reduction (CVR) and network topology reconfiguration (NTR) to manage demand, distributed energy resources (DERs), and tighter operating margins. Yet these strategies are typically deployed independently, despite coupled effects on feeder voltages, losses, and loading. This paper addresses that gap by developing a day-ahead mixed-integer second order cone programming (MISOCP) framework that jointly optimizes feeder head voltage control and network reconfiguration. The formulation incorporates AC branch flow constraints, ZIP load models, DERs, battery energy storage systems, and multi substation radiality. Using modified IEEE 33 bus and 123 bus systems, four configurations isolate the individual and coordinated effects of CVR and NTR. On the 33-bus system under mixed ZIP loading, NTR reduces active energy loss by 2.50%, while coordinated operation reduces it by 2.91% relative to SDN and produces a 2.46% CVR induced active load reduction relative to SDNTR. Under constant impedance loading, coordinated operation reduces active energy loss by 17.65% relative to SDN, while CVR reduces active load by 14.61% relative to SDNTR. DER portfolio scaling shows a nonmonotonic coordinated load reduction response, strongest at 20% penetration and decreasing at higher levels. On the 123 bus system, NTR reduces losses by 19.3%, while CVR reduces voltage dependent load energy by 2.3 to 2.4%. Under loading stress, SDN becomes infeasible at 120% loading, whereas CEDNTR remains feasible. Overall, the results demonstrate complementary, operating condition dependent benefits shaped by load composition, DER portfolio scaling, feeder topology, voltage margins, and source constraints, highlighting the value of joint optimization.

0.29

Low-Voltage Ride-Through in AI Data Centers via Coordinated Battery and Computing Load Control

eess.SY ·2026-11-14 ·Xiaoyang Wang, Xin Chen, Fang Chen Lin, Prasad Enjeti, Ali Yazdanpanah +2 more
hot direction similarity 0.52
Abstract · 5 pages, 7 figures

The ability of large AI data centers to ride through grid voltage sags is critical to power system stability and reliability. This paper frames data center low-voltage ride-through (LVRT) as a DC-link power balance problem. Once the rectifier reaches its current limit, the power drawn from the grid decreases in proportion to the grid voltage. The DC-link capacitor can supply the resulting power deficit only briefly before the DC-link voltage falls low enough to trigger undervoltage protection tripping. To address this issue, this paper proposes effective control strategies for coordinating uninterruptible power supply (UPS) battery and computing load curtailment to offset the power deficit and enable LVRT at minimum control cost. Three control scenarios are studied: UPS battery support alone, computing load curtailment alone, and the coordinated use of both resources. Electromagnetic transient (EMT) simulations using the TAMU-ERCOT AI data center model demonstrate that battery support and the coordinated strategy achieve LVRT for all tested sags, including a near-zero-voltage fault, while load curtailment alone rides through moderate voltage sags.

0.22

Why Three Phases? A Historical and Engineering Reassessment of Phase Order in AC Power Transmission

eess.SY ·2026-08-27 ·Kai Sun
unusual similarity 0.51
Abstract

Three-phase alternating current is so deeply embedded in modern electric-power infrastructure that its phase order is often treated as self-evident. Historically, however, 1-phase and true 2-phase systems were commercially important, while commercial 6-phase transmission was later demonstrated. This paper reassesses why 3 phases became the dominant architecture for bulk AC transmission. A general balanced \(m\)-phase formulation is used to show that constant aggregate instantaneous power is not unique to 3 phases: an ideal balanced 2-phase system also cancels the double-frequency power term and can generate a constant-magnitude rotating field. Consequently, the historical displacement of 2 phases cannot be explained by power smoothness alone. The comparison is instead organized around conductor architecture, insulation stress, machine and transformer utilization, conversion requirements, right-of-way utilization, and technological path dependence. A historical, commercial 6-phase demonstration showed that high-phase-order transmission was technically feasible and could improve corridor utilization. The paper then asks: if PE conversion and protection make phase count less costly, could \(m>3\) offer intrinsic advantages? Six such advantages are identified: modular decomposition into interleaved 3-phase groups, redundant control degrees of freedom, structured modal/fault analysis, increased corridor power density under field constraints, potentially higher natural loading and loadability, and enhanced harmonic/field cancellation. A companion derivation shows that phase count alone does not intrinsically reduce \(I^2R\) loss at fixed total conductor material and phase voltage. As a conditional conclusion, 3 phases are an unusually favorable historical optimum for electromechanical grids, but not a mathematically universal optimum for a future converter-dominated grid.

0.27