DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang

eess.SY ·submitted 2026-11-06 10:32 UTC · v1
unusual

Abstract

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

Comment
Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Closest papers

Nearest neighbours by meaning across the whole index.

An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

eess.SY ·2026-11-06 ·Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang
similarity 0.64
Abstract · 13 pages, 19 figures. Submitted to IEEE for possible publication

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

0.40

Analysis and Demonstration of a Current-Stiff, Isolated Capacitive Bridge Transformer

eess.SY ·2026-11-10 ·Patrick Nowakowski, Cameron Little, Mahima Gupta, Daniel C. Ludois
similarity 0.62
Abstract · 10 pages, 17 figures

The traditional Voltage Source Inverter (VSI) based Dual Active Bridge (DAB) utilizes a transformer at its center to provide galvanic isolation and a turns ratio for step up/down functionality. However, the transformer is often the limiting factor of the DAB, especially as semiconductor switching speeds improve, given steel core losses, winding losses, etc. This paper presents a new DAB architecture based on Current Source Inverters (CSIs) coupled through, and isolated by, an AC capacitive bridge, yielding a system called a Capacitive Bridge Transformer (CBT). The CBT architecture eliminates all magnetic components in the AC portion of the isolated DAB circuit, reducing frequency scaling barriers normally present in DABs. The paper introduces the CBT from the perspective of duality and then develops the DC-DC power flow equations, the internal apparent power equations, and effective turns ratio. The analytical models are verified by steady state and detailed time domain measurements on a 2 kW experimental prototype.

0.39

A Modulation Strategy for Bidirectional Integrated Onboard and Wireless EV Charging

eess.SY ·2026-11-12 ·Manveer Aujla, Gavin Feher, Caniggia Viana
published similarity 0.53
Abstract · 7 pages, 9 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

Integrated electric vehicle chargers reduce cost by sharing power conversion hardware between the onboard charger (OBC) and the wireless charger (WC). A previously proposed dual active bridge (DAB)-based OBC/WC shares the rectification stage between the OBC and WC; however, the modulation required to realize its wireless operation has not yet been reported. This paper details a modulation strategy that enables the operation of the integrated OBC/WC topology. Differential-mode operation is used for the OBC, and common-mode operation is used for the WC. In OBC mode, the shared full-bridge produces differential-mode voltage for wired power transfer while ideally generating zero common-mode voltage on the wireless charging path. In WC mode, the same full-bridge produces common-mode voltage for wireless power transfer while ideally generating zero differential-mode voltage on the onboard charging path. The method preserves conventional DAB phase-shift power control and enables bidirectional power transfer in wired and wireless charging modes without additional contactors. Design considerations for the OBC transformer and WC coils are derived based on the resulting square-wave voltage amplitudes. Offline PLECS simulations demonstrate power tracking and decoupled charger operation at $\pm$7.4 kW. Hardware-in-the-loop simulations using a PLECS RT Box and an external Texas Instruments microcontroller further validate the proposed modulation method.

0.43

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.51
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.49
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

Solid State Transformer - Next Generation MV Interface for Native DC loads

eess.SY ·2026-10-23 ·Steffan Hansen, Marco Liserre, Mohamed Moharram
similarity 0.48
Abstract · 8 pages, 5 figures

About PowerNexa PowerNexa is the project name for a start- up initiative driven by Marco Liserre and Steffan Hansen with the ambition to develop the next generation power grid interface. Battery integration and DC loads Ongoing electrification is fundamentally changing how electrical energy is produced and consumed. DC loads are becoming an integral part of the infrastructure while battery integration is increasingly needed to manage peak demand and address grid capacity constraints. The next generation grid interface PowerNexa aims to combine a fully controllable Medium Voltage grid interface with native battery integration and multiple DC voltage levels, based on an architecture designed for high efficiency, modularity and redundancy.

0.27

A Discrete Digital Isolator with Shielded Planar Transformer for Gate Driver Applications

eess.SY ·2026-11-17 ·Thomas A. Conway
similarity 0.48
Abstract · 5 pages, 11 figures

Galvanically isolated gate drivers are required in many power electronics applications. This paper describes an implementation of a digital isolator using discrete components with a planar coreless PCB signal transformer providing the isolation. The use of an electrostatic shield between the transformer windings is shown to provide sufficient common-mode transient immunity to support IGBT half-bridge drivers, an application subject to a severe dV/dt transient during switching. The design is verified through the experimental implementation of a prototype half bridge using two of the proposed discrete digital isolators with SiC power transistors and demonstrates common-mode transient immunity greater than 15 kV/us with very low implementation complexity.

0.31

Non-Blocking Fault Current Limiting Control of Half-Bridge MMCs for MTDC Transmission

eess.SY ·2026-08-31 ·Pengxiang Huang, Shahil Shah
similarity 0.47
Abstract

A key protection requirement in multiterminal HVDC (MTDC) transmission systems is to selectively isolate faulted areas using DC circuit breakers (DCCBs) during DC faults while keeping the rest of the systems in operation. However, in MTDC systems using half-bridge modular multilevel converters (HB-MMCs), the lack of inherent fault current suppression capability in HB-MMCs can cause converter blocking before fault clearance by DCCBs. This work presents an active fault current limiting (AFCL) control strategy for HB-MMCs to mitigate DC fault currents, thus avoiding converter blocking and reducing the breaking capability required of DCCBs. In addition, a systematic approach is proposed to design the AFCL control strategy under converter and network stability constraints. The effectiveness of the proposed strategy is demonstrated through PSCAD on two typical MTDC systems during DC faults.

0.20