CS Paper Radar

Analysis and Demonstration of a Current-Stiff, Isolated Capacitive Bridge Transformer

Patrick Nowakowski, Cameron Little, Mahima Gupta, Daniel C. Ludois

eess.SY ·submitted 2026-11-10 17:57 UTC · v1

Abstract

The traditional Voltage Source Inverter (VSI) based Dual Active Bridge (DAB) utilizes a transformer at its center to provide galvanic isolation and a turns ratio for step up/down functionality. However, the transformer is often the limiting factor of the DAB, especially as semiconductor switching speeds improve, given steel core losses, winding losses, etc. This paper presents a new DAB architecture based on Current Source Inverters (CSIs) coupled through, and isolated by, an AC capacitive bridge, yielding a system called a Capacitive Bridge Transformer (CBT). The CBT architecture eliminates all magnetic components in the AC portion of the isolated DAB circuit, reducing frequency scaling barriers normally present in DABs. The paper introduces the CBT from the perspective of duality and then develops the DC-DC power flow equations, the internal apparent power equations, and effective turns ratio. The analytical models are verified by steady state and detailed time domain measurements on a 2 kW experimental prototype.

Comment
10 pages, 17 figures

Closest papers

Nearest neighbours by meaning across the whole index.

DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

eess.SY ·2026-11-06 ·Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang
unusual similarity 0.62
Abstract · Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

0.38

A Modulation Strategy for Bidirectional Integrated Onboard and Wireless EV Charging

eess.SY ·2026-11-12 ·Manveer Aujla, Gavin Feher, Caniggia Viana
published similarity 0.57
Abstract · 7 pages, 9 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

Integrated electric vehicle chargers reduce cost by sharing power conversion hardware between the onboard charger (OBC) and the wireless charger (WC). A previously proposed dual active bridge (DAB)-based OBC/WC shares the rectification stage between the OBC and WC; however, the modulation required to realize its wireless operation has not yet been reported. This paper details a modulation strategy that enables the operation of the integrated OBC/WC topology. Differential-mode operation is used for the OBC, and common-mode operation is used for the WC. In OBC mode, the shared full-bridge produces differential-mode voltage for wired power transfer while ideally generating zero common-mode voltage on the wireless charging path. In WC mode, the same full-bridge produces common-mode voltage for wireless power transfer while ideally generating zero differential-mode voltage on the onboard charging path. The method preserves conventional DAB phase-shift power control and enables bidirectional power transfer in wired and wireless charging modes without additional contactors. Design considerations for the OBC transformer and WC coils are derived based on the resulting square-wave voltage amplitudes. Offline PLECS simulations demonstrate power tracking and decoupled charger operation at $\pm$7.4 kW. Hardware-in-the-loop simulations using a PLECS RT Box and an external Texas Instruments microcontroller further validate the proposed modulation method.

0.34

A Discrete Digital Isolator with Shielded Planar Transformer for Gate Driver Applications

eess.SY ·2026-11-17 ·Thomas A. Conway
similarity 0.53
Abstract · 5 pages, 11 figures

Galvanically isolated gate drivers are required in many power electronics applications. This paper describes an implementation of a digital isolator using discrete components with a planar coreless PCB signal transformer providing the isolation. The use of an electrostatic shield between the transformer windings is shown to provide sufficient common-mode transient immunity to support IGBT half-bridge drivers, an application subject to a severe dV/dt transient during switching. The design is verified through the experimental implementation of a prototype half bridge using two of the proposed discrete digital isolators with SiC power transistors and demonstrates common-mode transient immunity greater than 15 kV/us with very low implementation complexity.

0.30

A Single-Inductor N:1 Resonant Switched-Capacitor Ladder Converter with Efficient Continuous Voltage Conversion Capability

eess.SY ·2026-10-07 ·Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem
similarity 0.49
Abstract

This paper presents an N:1 resonant switched-capacitor (ReSC) ladder converter of an output voltage that can be regulated continuously below the native N:1 resonant ratio while maintaining high efficiency. The topology can be generalized to any N-to-1 dc-dc conversion application while requiring only a single inductor. Efficient wide-range voltage regulation is realized by operating the bottom stack of the ReSC switches as diodes to maintain their switching always in phase with the inductor current, and hence, circumvent circulating currents that increase the inductor RMS current and ohmic losses under frequency control. A theoretical model has been developed to predict the output voltage and efficiency of the converter, with simulation results confirming its accuracy for N = 1, 2, and 4. A hardware prototype on a printed circuit board is developed to validate the performance of the proposed frequency-controlled regulation scheme. The prototype achieves a peak efficiency of 97% (94.3%) with a load of 30Ohms (resp. 6Ohms) and an efficiency >90% while generating a 9V USB-compatible voltage from a 40V-to-60V input. The measurement results match the model predictions within 0.63% accuracy.

0.52

An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

eess.SY ·2026-11-06 ·Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang
similarity 0.48
Abstract · 13 pages, 19 figures. Submitted to IEEE for possible publication

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

0.40

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.47
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

An Inductively Assisted N :1 Switched-Capacitor Ladder Converter

eess.SY ·2026-11-10 ·Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem
similarity 0.47
Abstract

This paper proposes an inductively assisted N:1 switched-capacitor ladder buck (D-SCLB) converter that replaces the output-side switch in the bottom half-bridge of an N:1 SCLB with a small inductor placed in parallel with the ladder capacitors during the demagnetization phase. The flying capacitors share the load current delivery, lowering the average inductor current to (1-M)Iout and enabling continuous regulation with M=D/(N-1+D). A closed-form output-impedance model, valid for arbitrary N under both optimal and uniform switch sizing, is derived and compared against SC, SCLB, FCMC, and DPSC topologies. For a 4:1 48V-to-PoL design, the D-SCLB reduces the average inductor current by up to 20% and improves the equivalent output impedance by up to 30% relative to the SCLB. Two hardware prototypes on a low-cost two-layer PCB achieve a peak efficiency of 96.2%, with the D-SCLB using 49% smaller inductor volume than the SCLB at comparable efficiency. Model predictions agree with measurements to within 1.5% under heavy load.

0.15

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.47
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36