CS Paper Radar

A Single-Inductor N:1 Resonant Switched-Capacitor Ladder Converter with Efficient Continuous Voltage Conversion Capability

Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem

eess.SY ·submitted 2026-10-07 01:12 UTC · v1

Abstract

This paper presents an N:1 resonant switched-capacitor (ReSC) ladder converter of an output voltage that can be regulated continuously below the native N:1 resonant ratio while maintaining high efficiency. The topology can be generalized to any N-to-1 dc-dc conversion application while requiring only a single inductor. Efficient wide-range voltage regulation is realized by operating the bottom stack of the ReSC switches as diodes to maintain their switching always in phase with the inductor current, and hence, circumvent circulating currents that increase the inductor RMS current and ohmic losses under frequency control. A theoretical model has been developed to predict the output voltage and efficiency of the converter, with simulation results confirming its accuracy for N = 1, 2, and 4. A hardware prototype on a printed circuit board is developed to validate the performance of the proposed frequency-controlled regulation scheme. The prototype achieves a peak efficiency of 97% (94.3%) with a load of 30Ohms (resp. 6Ohms) and an efficiency >90% while generating a 9V USB-compatible voltage from a 40V-to-60V input. The measurement results match the model predictions within 0.63% accuracy.

Closest papers

Nearest neighbours by meaning across the whole index.

An Inductively Assisted N :1 Switched-Capacitor Ladder Converter

eess.SY ·2026-11-10 ·Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem
similarity 0.70
Abstract

This paper proposes an inductively assisted N:1 switched-capacitor ladder buck (D-SCLB) converter that replaces the output-side switch in the bottom half-bridge of an N:1 SCLB with a small inductor placed in parallel with the ladder capacitors during the demagnetization phase. The flying capacitors share the load current delivery, lowering the average inductor current to (1-M)Iout and enabling continuous regulation with M=D/(N-1+D). A closed-form output-impedance model, valid for arbitrary N under both optimal and uniform switch sizing, is derived and compared against SC, SCLB, FCMC, and DPSC topologies. For a 4:1 48V-to-PoL design, the D-SCLB reduces the average inductor current by up to 20% and improves the equivalent output impedance by up to 30% relative to the SCLB. Two hardware prototypes on a low-cost two-layer PCB achieve a peak efficiency of 96.2%, with the D-SCLB using 49% smaller inductor volume than the SCLB at comparable efficiency. Model predictions agree with measurements to within 1.5% under heavy load.

0.19

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.56
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.54

Analysis and Demonstration of a Current-Stiff, Isolated Capacitive Bridge Transformer

eess.SY ·2026-11-10 ·Patrick Nowakowski, Cameron Little, Mahima Gupta, Daniel C. Ludois
similarity 0.49
Abstract · 10 pages, 17 figures

The traditional Voltage Source Inverter (VSI) based Dual Active Bridge (DAB) utilizes a transformer at its center to provide galvanic isolation and a turns ratio for step up/down functionality. However, the transformer is often the limiting factor of the DAB, especially as semiconductor switching speeds improve, given steel core losses, winding losses, etc. This paper presents a new DAB architecture based on Current Source Inverters (CSIs) coupled through, and isolated by, an AC capacitive bridge, yielding a system called a Capacitive Bridge Transformer (CBT). The CBT architecture eliminates all magnetic components in the AC portion of the isolated DAB circuit, reducing frequency scaling barriers normally present in DABs. The paper introduces the CBT from the perspective of duality and then develops the DC-DC power flow equations, the internal apparent power equations, and effective turns ratio. The analytical models are verified by steady state and detailed time domain measurements on a 2 kW experimental prototype.

0.39

Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K

eess.SY ·2026-10-20 ·Rami Rasheedi, Umeshkumar Patel, Jonathan Baldwin, Antonino Miceli, Inna Partin-Vaisband
unusual similarity 0.47
Abstract

With the increasing complexity and scalability demands of cryogenic electronic systems, such as quantum computing platforms, conversion of power within the cryogenic environment has become a primary concern. Magnetic inductors are among the key components affecting converter performance, as their electrical and magnetic properties can change significantly at low temperatures. In this paper, five commercially available Vishay SMD power inductors are experimentally characterized down to 4 K: DC resistance is measured continuously during cooldown, while frequency-dependent AC inductance and resistance are measured up to 2 MHz at both room temperature and 4 K. The results show substantial DC resistance reductions of 25x-58x at 4 K, while the inductance degrades by only about 5-5.5%. Although cryogenic operation slightly increases the AC resistance (due to the intensified skin effect) and raises core losses, converter-level analysis shows an inductor-only efficiency improvement of approximately 5.3-6.9 percentage points at 1 A, and up to 22.8 points at 3 A. The measured frequency-dependent impedance of each inductor is imported into Cadence and a complete single-phase 24 V-to-1 V buck converter with GaN power devices is simulated at 1, 2, and 3 A at 4 K. The full-converter efficiency at 4 K is shown to improve by 3.0-5.2 percentage points at 1 A and by up to 22.5 points at 3 A for the AC-characterized devices. These findings indicate that commercially available off-the-shelf power inductors remain operationally viable under cryogenic conditions and can simultaneously increase inductor efficiency and reduce the overall power loss in cryogenic power conversion systems.

0.24

DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

eess.SY ·2026-11-06 ·Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang
unusual similarity 0.45
Abstract · Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

0.38

Improved Single-Input Space Vector for DC-Biased Sinusoidal Current Control in Battery Cyclers

eess.SY ·2026-11-12 ·Manveer Aujla, Philip Lewoc, Harminderjit S. Toor, Ahmad Ali, Caniggia Viana +1 more
publishedunusual similarity 0.43
Abstract · 8 pages, 17 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

This paper presents improvements to the single-input space vector (SISV) concept for current control in a battery cycler based on a two-phase interleaved buck converter. The cycler is controlled to output a dc-biased sinusoidal current, enabling investigation of second-harmonic ripple effects on lithium-ion cell aging. A modified SISV generation scheme is introduced to track current references containing both dc and sinusoidal components, and an impedance-angle compensation method is proposed to decouple the d and q control axes without disturbing dc tracking. A dq phase-portrait visualization method is also introduced to evaluate transient performance for both SISV and proportional-integral-resonant (PIR) control methods. Simulation and experimental results validate dc-biased sinusoidal current tracking using PIR control and SISV control with different decoupling schemes. The phase-portrait framework allows for straightforward evaluation of transient performance for both SISV and PIR control methods and supports controller tuning to obtain desired trajectories. The results demonstrate the feasibility of SISV-based current control as an alternative to PIR control for battery-cycler applications. The proposed improvements support the development of battery cyclers capable of controlling both dc and sinusoidal current components.

0.46

PLL-Less Synchronization of Grid-Following Converters Using a Voltage-Driven Frenet Frame

eess.SY ·2026-11-13 ·Jinhui Chen, Huadong Sun, Shiyun Xu, Bing Zhao, Peng Han +1 more
benchmark similarity 0.43
Abstract

In grid-following converters, the synchronization path can transmit voltage disturbances to the current loop under weak or unbalanced grid conditions. This paper develops a Frenet-frame controller that derives its axes from the integral curve of the measured voltage at the point of common coupling. The tangential current governs active power, while the normal and binormal currents govern the transverse components of non-active power. Feedforward terms derived from the output filter model compensate curvature and torsion coupling, yielding identical nominal current dynamics across the axes. The controller operates without a phase-locked loop or sequence extraction. A reduced transverse model accounts for the finite bandwidth of geometric rate reconstruction and predicts a reduction in low-frequency coupling from voltage disturbances to current. Controller hardware-in-the-loop tests using real-time simulation of a three-phase four-wire converter show the shortest settling time after an active power reference step and the smallest peak power deviations during balanced voltage disturbances among the tested controllers. Under single-phase voltage unbalance, the method reduces peak binormal current and maximum phase-current total harmonic distortion relative to both benchmarks. It also settles to the commanded power in a weak-grid connection test where the phase-locked loop benchmark exhibits sustained oscillations.

0.38

Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control

eess.SY ·2026-10-23 ·Wanrong Li, Shuhan Hu, Hengping Xiong, Runnan Wang, Huawei Yuan +2 more
published similarity 0.42
Abstract · Accepted at the 2026 CPSS & IEEE International Symposium on Energy Storage and Conversion (ISESC)

Cascaded DC systems may become unstable through source-load impedance interactions even when their constituent converters are locally stable. This paper proposes a source-side model-free control (MFC) method that reuses bus-voltage feedback to reshape the source output impedance while preserving nominal reference-to-output dynamics. The controller uses only nominal source-loop information and requires neither a load-converter model nor load-side measurements. A current-controlled buck source supplying a regulated buck-resistor load that exhibits constant-power load (CPL) behaviour at low frequencies is used as the case study. Impedance analysis predicts that the proposed MFC increases the maximum stable load power by approximately 50%, thereby improving the stability margin of the cascaded system. Switched-model simulations confirm preservation of the nominal reference-to-output response and show that the MFC-controlled system remains stable at load levels for which the baseline system becomes unstable.

0.40