Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control

Wanrong Li, Shuhan Hu, Hengping Xiong, Runnan Wang, Huawei Yuan, Jianguo Zhu, Sinan Li

eess.SY ·submitted 2026-10-23 02:27 UTC · v1
published

Abstract

Cascaded DC systems may become unstable through source-load impedance interactions even when their constituent converters are locally stable. This paper proposes a source-side model-free control (MFC) method that reuses bus-voltage feedback to reshape the source output impedance while preserving nominal reference-to-output dynamics. The controller uses only nominal source-loop information and requires neither a load-converter model nor load-side measurements. A current-controlled buck source supplying a regulated buck-resistor load that exhibits constant-power load (CPL) behaviour at low frequencies is used as the case study. Impedance analysis predicts that the proposed MFC increases the maximum stable load power by approximately 50%, thereby improving the stability margin of the cascaded system. Switched-model simulations confirm preservation of the nominal reference-to-output response and show that the MFC-controlled system remains stable at load levels for which the baseline system becomes unstable.

Comment
Accepted at the 2026 CPSS & IEEE International Symposium on Energy Storage and Conversion (ISESC)

Closest papers

Nearest neighbours by meaning across the whole index.

Model-Free Output-Admittance Reshaping for Stability Enhancement of Grid-Connected Inverters

eess.SY ·2026-10-23 ·Runnan Wang, Wanrong Li, Huawei Yuan, Sinan Li
published similarity 0.59
Abstract · Accepted at the 2026 IEEE PES Australasian Universities Power Engineering Conference (AUPEC)

Grid-connected inverters can be unstable when their current-control loops interact with an uncertain external network. Returning the existing controller to improve damping also alters current tracking because tracking dynamics and output admittance are coupled. This paper adds a local model-free control (MFC) loop around the existing current controller to reduce output admittance while closely preserving nominal current-tracking dynamics. The added loop uses local inverter parameters without an external grid or neighbouring converter model. A Norton formulation separates reference tracking from the current response to terminal-voltage disturbances and establishes a tracking-preservation condition for admittance reshaping. Reducing the disturbance response makes the inverter behave more like an ideal controlled current source. Averaged-model simulations show reductions exceeding 65% in the magnitudes of all four dq output-admittance elements over 10-200 Hz, with closely preserved current-tracking dynamics. Generalised Nyquist analysis predicts small-signal stability for all sampled grid-impedance cases with MFC, compared with 90.0% without MFC.

0.28

Impedance-Based Sensitivity Analysis for Stability Enhancement of LCC-HVDC Links Connected to Weak Grids Using Grid-Forming Converters

eess.SY ·2026-09-09 ·Luis A. Garcia-Reyes, Anup Joshi, Javier Renedo, Macarena Martin-Almenta, Oriol Gomis-Bellmunt +3 more
benchmark similarity 0.57
Abstract · Best Paper Award in the 2026 5th IEEE International Conference on Power Systems and Electrical Technology

This paper presents a frequency-domain, impedance-based sensitivity methodology for stability assessment and enhancement of line-commutated converter HVDC (LCC-HVDC) links operating under weak-grid conditions. The methodology integrates frequency-domain identification tailored for black-box systems, the Generalized Nyquist Criterion (GNC) for multivariable stability assessment, and modal impedance decomposition with participation-factor analysis to locate and interpret interaction mechanisms. The approach is validated against a detailed linearized state-space model and nonlinear EMT simulations of an LCC-HVDC benchmark. A sensitivity study varying the grid short-circuit ratio (SCR) reveals a stability limit for the standalone LCC-HVDC link and demonstrates that the integration of a grid-forming voltage source converter (GFM-VSC) substantially increases the stability margin.

0.20

Grid-Forming AC/DC Converters for Meshed DC Networks via Dual-Measurement Frequency Droop

eess.SY ·2026-10-26 ·Hisham Mahmood, Marcelo A. Elizondo
similarity 0.56
Abstract · 10 pages, 12 figures, 1 table

This paper proposes and analyzes a dual-measurement frequency-droop (DMFD) controller for meshed MVDC networks. Using only two local DC measurements, bus-voltage deviation and a filtered DC-port current or power deviation, the controller enables grid-forming operation at both AC and DC ports across the mesh. Although the DMFD regulates neither the DC voltage nor the DC current directly and acts only on the terminal frequency, it is shown that AC-side synchronization closes an effective DC droop at every synchronized terminal, so that the steady operating point of the mesh exists and is unique. Constant frequency deviations at a terminal and single-terminal islanding enter the same DC equations as equivalent current offsets, with the island frequency fixed by the island power balance, allowing node voltages and branch currents to be obtained from one linear system. The steady-state model yields design-use envelopes to map the droop ratios and the net DC-injection levels into bounds on DC-voltage deviation and terminal currents. A small-signal dynamic model is developed and used to generate eigenvalue loci and damping-ratio charts that guide controller-gain selection. Averaged EMT simulations on a four-terminal ring corroborate the analysis: in regimes where PLL-based grid-following control is known to lose damping, the DMFD controller maintains stable operation and follows the predicted steady-state characteristics.

0.29

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.55
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.54

Reshaping Converter-Network Interactions in Microgrids: From Virtual Impedance to Virtual Two-Port Control

eess.SY ·2026-09-23 ·Liaoyuan Yang, Peng Yang, Yang Wu, Feng Liu
similarity 0.55
Abstract

Converter terminal characteristics are central to both dynamic interactions with the network and steady-state power sharing in inverter-based microgrids. Conventional additive virtual impedance (VI) shapes these characteristics through a single virtual branch. This paper proposes virtual two-port control, which uses four coordinated transfer channels to reconstruct the terminal impedance. The connected network consequently observes the original converter through a virtually inserted twoport interface, with conventional virtual impedance recovered as a degenerate case. The proposed control transforms the original impedance through a matrix linear-fractional map. We also derive a necessary and sufficient condition for the reconstruction to be stable and proper. Among its various potential applications in microgrids, we develop three representative ones in detail: passivation with reduced control effort, uncertainty compression, and seriesshunt power-flow regulation. Simulations of VSG-controlled converters demonstrate the advantages of the proposed method over conventional VI in these applications.

0.23

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.54
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

An Energy-Based Framework for Transient Stability of Grid-Forming Converter Networks With Current Limiting

eess.SY ·2026-09-29 ·Wei Zhou, Yunjie Gu
similarity 0.54
Abstract · 10 pages, 6 figures

Existing analyses for the transient stability of grid-forming (GFM) converters under current limiting mainly address single-converter systems, while network-level transient stability analysis remains challenging. This paper develops a network energy construction that incorporates current limiting while retaining a provable dissipation property. This structure enables Lyapunov-based analysis consistent with classical direct method for synchronous-machine based systems, without switching between mode-dependent energy functions. A two-GFM example using a reactive circular current limiter and impedance insertion illustrates the proposed framework. Electromagnetic transient simulations support the theoretical results.

0.25

Decentralised Plug-and-Play Stability Conditions for AC Grids-Part I

eess.SY ·2026-09-07 ·Liam Hallinan, Ioannis Lestas
similarity 0.53
Abstract · 15 pages, 10 figures

The rise of renewable generation in AC power systems calls for small-signal stability assessment methods that do not rely on centralised, system-wide models. In this two-part paper, we present a decentralised stability framework based on frequency-domain conditions imposed on local subsystems (many admitting equivalent graphical interpretations) which collectively imply the stability of the entire grid. The framework generalises many previously reported results, with added flexibility and plug-and-play compatibility provided by the additional degrees of freedom of the imposed conditions, the ability to mix conditions across frequency ranges, conditions on extended subsystems that couple buses to their connecting lines and loads, and a method to incorporate unstable subsystems. Detailed, heterogeneous device and line models are accommodated in the frequency domain using impedance, admittance, and power-flow models, making the framework suitable as a foundation for grid codes that enable plug-and-play functionality in inverter-dominated grids. Part I focuses on stable impedance and admittance representations and Part II extends the results to unstable subsystems, which are shown to be fundamentally present in many grid models. The results of Part I are validated on a modified 9-bus case study, demonstrating the reduced conservatism and significance of the proposed approach.

0.54