Abstract

This paper presents a frequency-domain, impedance-based sensitivity methodology for stability assessment and enhancement of line-commutated converter HVDC (LCC-HVDC) links operating under weak-grid conditions. The methodology integrates frequency-domain identification tailored for black-box systems, the Generalized Nyquist Criterion (GNC) for multivariable stability assessment, and modal impedance decomposition with participation-factor analysis to locate and interpret interaction mechanisms. The approach is validated against a detailed linearized state-space model and nonlinear EMT simulations of an LCC-HVDC benchmark. A sensitivity study varying the grid short-circuit ratio (SCR) reveals a stability limit for the standalone LCC-HVDC link and demonstrates that the integration of a grid-forming voltage source converter (GFM-VSC) substantially increases the stability margin.

Comment
Best Paper Award in the 2026 5th IEEE International Conference on Power Systems and Electrical Technology

Closest papers

Nearest neighbours by meaning across the whole index.

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.67
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

Generalized Frequency-Domain Stability Analysis Formulation for Multi-Terminal HVDC Systems

eess.SY ·2026-11-05 ·Francisco J. Cifuentes Garcia, Thomas Roose, Luis Müller, Jef Beerten
code/data similarity 0.67
Abstract · Under review (10 pages). For the associated packages visit http://github.com/Electa-Git/PowerImpedance.jl and http://github.com/Electa-Git/Z…

The integration of offshore wind farms (OWFs) and the interconnection of different transmission networks are key drivers for multi-terminal DC (MTDC) systems. Bipolar high-voltage direct current (HVDC) employing dedicated metallic return (DMR) are attractive due to their increased availability, which co-exist with monopolar and rigid bipole configurations. While existing works focus on symmetric operation and particular configurations, we present a unified framework for MTDC stability analysis valid for both symmetric and asymmetric conditions. The formulation uses the minimum number of variables without loss of information, and combines the analytical network representation with black-box converter models, thereby enabling sensitivity studies. In addition, a closed-form expression guiding the stability improvement is presented, which requires minimal data exchange between involved parties. The framework is demonstrated on several case studies of increasing complexity, which highlight the importance of considering intra-station converter couplings and possible uncertainty of network parameters.

0.44

Limitations of RMS-based Stability Assessment of Converter-based Grids: A Case Study

eess.SY ·2026-08-19 ·Pol Jane-Soneira, Ognjen Stanojev, Francisco Canales Perez, Qian Long, Mario Schweizer +1 more
similarity 0.64
Abstract

The increasing penetration of power electronic converters in industrial grids introduces stability challenges at frequencies well above the electromechanical range of traditional power systems. Commercial software tools typically perform eigenvalue-based stability analysis using root-mean-square (RMS) models that assume a quasi-stationary network, thereby neglecting electromagnetic dynamics of assets --- which is standard practice in power system analysis. This paper presents a case study of an industrial grid where the conventional RMS-based eigenvalue analysis predicts stable operation, while a detailed electromagnetic transient (EMT) simulation reveals growing oscillations, indicating instability. To bridge this gap, we introduce an alternative modeling approach that formulates the network dynamics in the rotating $dq$ reference frame, retaining the differential equations of electromagnetic dynamics. The resulting model enables eigenvalue analysis that correctly identifies the unstable modes, consistent with the EMT simulation results. Our findings highlight a fundamental limitation of RMS-based stability assessment for converter-dominated grids and demonstrate that dynamic impedance models in the dq frame provide a viable path toward accurate small-signal analysis encompassing high-frequency converter-network interactions.

0.32

Decentralized Impedance Specifications for Grid-Connected Converters: a Sequence-Domain Gershgorin Method, and a Frequency-Wise Framework for Combining Different Criteria

eess.SY ·2026-11-03 ·Lazar Stojanović, Ružica Cvetanović, Paolo Mattavelli, Simone Buso
similarity 0.62
Abstract

In complex grid scenarios, with many power electronics (PE) converters connected, having specifications for converters can ease the design process. A practical approach is to impose the specifications on the converter's small-signal impedance in the frequency domain. This is advantageous since impedance is a physical property that can be measured. This paper focuses on providing decentralized impedance specifications for each converter connected to an ac bus. With decentralized specifications, each converter has its own specifications, which are independent of other converters' impedance. This enables a competitive multi-vendor environment while guaranteeing system stability. Existing methods of imposing decentralized specifications, based on the small-gain, passivity and Gershgorin theorems, are formulated within a common frequency-domain framework. Building on this, two new solutions that reduce the conservativeness of the specifications are proposed. First, Gershgorin-based decentralized specifications are formulated in the modified sequence domain. Second, a framework for combining different specification types across frequency ranges is developed and mathematically proven. The methods are compared on examples covering sub-synchronous and harmonic-range interactions of grid-following converters, grid-forming converters, and a mixed grid-forming/grid-following system, using analytical models, black-box impedance measurements, and time-domain responses obtained from simulations and an experimental setup.

0.24

Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints

eess.SY ·2026-09-28 ·Xiaoying Liu, Linbin Huang, Hangyu Chen, Huanhai Xin
similarity 0.62
Abstract

Small-signal stability analysis of power electronics-dominated power systems is becoming increasingly challenging due to the large-scale integration of heterogeneous grid-following (GFL) and grid-forming (GFM) converters. Classical centralized methods, such as eigenvalue analysis and the generalized Nyquist criterion, provide direct stability assessment tools but exhibit limited scalability as the system size increases. This motivates scalable analysis methods for stability assessment and device-level diagnosis, and calls for less conservative stability conditions. To this end, this paper proposes a scalable small-signal stability assessment method with quantitative stability indices for multi-converter systems based on frequency-domain quadratic constraints (FQCs). It is shown that several existing stability conditions, including geometric conditions based on the Davis-Wielandt (DW) shell, numerical range, $x$-$z$ graph, scaled relative graph (SRG), mixed gain-phase condition, and passivity condition, are special cases of the FQC-based stability condition. This FQC-based formulation also clarifies the requirements for decentralized verification of these existing stability conditions. To further reduce conservatism, a full-multiplier FQC-based stability condition is developed, based on which an optimization problem is formulated for scalable stability certification and device-level diagnosis using quantitative stability indices without relying on graphical inspection. Combined with the mixed gain-phase condition, this optimization problem forms a hierarchical screening-diagnosis procedure that improves efficiency. Case studies demonstrate that the proposed method is less conservative than existing criteria and can effectively identify problematic devices associated with potential instability risks.

0.39

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation

eess.SY ·2026-10-28 ·Songyang Zhang, Xun Gong, Bo Cao, Reza Iravani
similarity 0.61
Abstract

Passive grid impedance estimators that return a single resistance--inductance pair cannot represent a grid whose phase impedances are unequal. This paper identifies a separate pair for each phase from recorded point-of-common-coupling (PCC) voltage and current without injected perturbations. In each phase, the unknown grid-source voltage is cancelled by a periodic difference (PD) or by a second-order-generalized-integrator notch difference (SOGID), and moving-window integration (MWI) replaces the current derivative by an integral and an endpoint feature. The resulting two-parameter regression requires a period or notch-frequency estimate but no phase-locked-loop angle. A voltage-balance analysis gives the source residual left by frequency mismatch and bounds the parameter error by the ratio of this residual to the conditioning of the two features. In the unequal-phase interval (8.3--9.8~s) of a 10-s EMTP grid-forming record, SOGID-MWI attains phase-averaged R/L errors of 5.09/0.33\%; a shared value has a minimum error of 41.67\% for the phase ratio 1:0.5:2. On a 50-s constant-impedance grid-following record, the errors are 0.56/0.06\% over the 20--30-s synchronization disturbance. In a controlled 40-dB noise study, a noise-referenced update rule reduces the white-noise GFL error from 55.9/65.0\% to 12.3/11.5\%.

0.34

Impact of Reduced-Order Modelling on Sum-of-Squares Region-of-Attraction Certification for Grid-Forming and Grid-Following Converters

eess.SY math.OC ·2026-11-10 ·Chenxi Yuan, Jeremy D. Watson, Neville R. Watson
similarity 0.58
Abstract · 13 pages, 5 figures, 3 tables

With the increasing penetration of power-electronic equipment, the transient stability of grid-forming (GFM) and grid-following (GFL) converters is increasingly characterized through the region of attraction (ROA) of the post-fault equilibrium. Sum-of-squares (SOS) programming yields certified inner approximations of the ROA, yet its computational cost grows rapidly with system order. Reduced-order models are therefore widely used to reduce computational cost and, more importantly, to enable analytical investigation. However, ROA analyses based on these models often assume that reproducing the converter's transient response, or retaining more dynamics in the correct time-frame, is sufficient to preserve the ROA of the full-order system. Using time-domain ODE simulations as a reference, the SOS-based ROA of each reduced-order GFM and GFL model is assessed against both its own simulated ROA and that of the corresponding full-order model, thereby separating SOS-induced conservativeness from model-order-induced ROA distortion. The results indicate that increasing reduced-order model complexity does not necessarily improve SOS-based ROA fidelity. In the cases examined, more complex reduced-order models yield lower SOS coverage of the full-order reference ROA, despite closer ODE-boundary agreement in some regions. Model selection should therefore consider both full-order ROA fidelity and certified coverage of the practical operating range, rather than model complexity alone.

0.27

Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control

eess.SY ·2026-10-23 ·Wanrong Li, Shuhan Hu, Hengping Xiong, Runnan Wang, Huawei Yuan +2 more
published similarity 0.57
Abstract · Accepted at the 2026 CPSS & IEEE International Symposium on Energy Storage and Conversion (ISESC)

Cascaded DC systems may become unstable through source-load impedance interactions even when their constituent converters are locally stable. This paper proposes a source-side model-free control (MFC) method that reuses bus-voltage feedback to reshape the source output impedance while preserving nominal reference-to-output dynamics. The controller uses only nominal source-loop information and requires neither a load-converter model nor load-side measurements. A current-controlled buck source supplying a regulated buck-resistor load that exhibits constant-power load (CPL) behaviour at low frequencies is used as the case study. Impedance analysis predicts that the proposed MFC increases the maximum stable load power by approximately 50%, thereby improving the stability margin of the cascaded system. Switched-model simulations confirm preservation of the nominal reference-to-output response and show that the MFC-controlled system remains stable at load levels for which the baseline system becomes unstable.

0.40