CS Paper Radar

Improved Single-Input Space Vector for DC-Biased Sinusoidal Current Control in Battery Cyclers

Manveer Aujla, Philip Lewoc, Harminderjit S. Toor, Ahmad Ali, Caniggia Viana, Narayan C. Kar

eess.SY ·submitted 2026-11-12 15:15 UTC · v1
publishedunusual

Abstract

This paper presents improvements to the single-input space vector (SISV) concept for current control in a battery cycler based on a two-phase interleaved buck converter. The cycler is controlled to output a dc-biased sinusoidal current, enabling investigation of second-harmonic ripple effects on lithium-ion cell aging. A modified SISV generation scheme is introduced to track current references containing both dc and sinusoidal components, and an impedance-angle compensation method is proposed to decouple the d and q control axes without disturbing dc tracking. A dq phase-portrait visualization method is also introduced to evaluate transient performance for both SISV and proportional-integral-resonant (PIR) control methods. Simulation and experimental results validate dc-biased sinusoidal current tracking using PIR control and SISV control with different decoupling schemes. The phase-portrait framework allows for straightforward evaluation of transient performance for both SISV and PIR control methods and supports controller tuning to obtain desired trajectories. The results demonstrate the feasibility of SISV-based current control as an alternative to PIR control for battery-cycler applications. The proposed improvements support the development of battery cyclers capable of controlling both dc and sinusoidal current components.

Comment
8 pages, 17 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

Closest papers

Nearest neighbours by meaning across the whole index.

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.54
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.52
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.53

Battery-Aware Predictive Trajectory Planning and Control for Multirotors Under Disturbances

cs.RO eess.SY ·2026-09-10 ·Krishna Bhavithavya Kidambi
similarity 0.52
Abstract

This paper presents a battery-aware predictive trajectory-planning and control framework for multirotors operating under spatially localized disturbances. Candidate trajectories are evaluated through closed-loop vehicle--motor--battery propagation, allowing disturbance-induced control demand, electrical energy, battery evolution, and terminal-voltage-dependent actuator capability to enter the planning process. % A reduced-order battery model is numerically benchmarked against an independently implemented Simscape equivalent-circuit reference, with a power NRMSE of $0.64\%$ and a cumulative-energy discrepancy below $0.7\%$. % In a $150$-s, $640$-m mission containing three disturbance regions, the selected trajectory reduces electrical energy consumption by $7.46\%$ and position-tracking RMSE by approximately $72\%$ relative to the disturbance-aware fixed-reference baseline. % Planner ablations show that battery-dependent terms are nonbinding at nominal SOC but alter the selected trajectory under a depleted-battery stress condition. % Execution with multiple feedback controllers further demonstrates that controller selection changes the tradeoff among tracking accuracy, energy consumption, and actuator utilization. % The results demonstrate the benefit of accounting for predicted closed-loop energetic and battery--actuator consequences during trajectory selection.

0.26

PLL-Less Synchronization of Grid-Following Converters Using a Voltage-Driven Frenet Frame

eess.SY ·2026-11-13 ·Jinhui Chen, Huadong Sun, Shiyun Xu, Bing Zhao, Peng Han +1 more
benchmark similarity 0.51
Abstract

In grid-following converters, the synchronization path can transmit voltage disturbances to the current loop under weak or unbalanced grid conditions. This paper develops a Frenet-frame controller that derives its axes from the integral curve of the measured voltage at the point of common coupling. The tangential current governs active power, while the normal and binormal currents govern the transverse components of non-active power. Feedforward terms derived from the output filter model compensate curvature and torsion coupling, yielding identical nominal current dynamics across the axes. The controller operates without a phase-locked loop or sequence extraction. A reduced transverse model accounts for the finite bandwidth of geometric rate reconstruction and predicts a reduction in low-frequency coupling from voltage disturbances to current. Controller hardware-in-the-loop tests using real-time simulation of a three-phase four-wire converter show the shortest settling time after an active power reference step and the smallest peak power deviations during balanced voltage disturbances among the tested controllers. Under single-phase voltage unbalance, the method reduces peak binormal current and maximum phase-current total harmonic distortion relative to both benchmarks. It also settles to the commanded power in a weak-grid connection test where the phase-locked loop benchmark exhibits sustained oscillations.

0.29

Koopman-Based Model Predictive Control for Simultaneous State of Charge and Temperature Balancing of Lithium-Ion Cells

eess.SY ·2026-09-07 ·Jihoon Moon
similarity 0.51
Abstract

Cell-to-cell electrical and thermal variations produce nonuniform state of charge (SoC) and temperature distributions in lithium-ion battery packs. This paper proposes a Koopman-operator-based framework for simultaneous SoC and temperature balancing of series-connected cells. Cell-specific Koopman predictors identified using extended dynamic mode decomposition are assembled into neighboring-cell error dynamics that retain heterogeneity and thermal-disturbance effects. A Tikhonov-regularized feedforward controller provides numerically robust compensation without excessive current amplification, while constrained Koopman-based model predictive control (KMPC) regulates the residual errors through a convex quadratic program. Three-cell simulations validate the controller under two consecutive Urban Dynamometer Driving Schedule cycles. KMPC achieves balancing performance comparable to nonlinear model predictive control (NMPC). Relative to the uncontrolled case, KMPC reduces the RMSEs of the neighboring-cell SoC and core temperature differences by 66-81% and 57-76%, respectively, while reducing the computation time per optimization from 0.0259s for NMPC to 0.0028s for KMPC.

0.31

Impedance-Aware Optimized Pulse Patterns for Reconfigurable Battery Systems

eess.SY ·2026-09-15 ·Julian Estaller, Johannes Buberger, Andreas Wiedenmann, Wolfgang Grupp, Tobias Hoegerl +1 more
similarity 0.51
Abstract · 11 pages, 6 figures. Submitted to the IEEE Open Journal of Power Electronics

Reconfigurable battery systems (RBS) synthesize the converter output voltage by inserting and bypassing battery cell groups, so every switching state changes not only the source voltage but also the source impedance. This paper shows that this configuration-dependent impedance breaks a tacit assumption of optimized pulse patterns (OPP): patterns designed with the customary linear plant model overestimate their achievable current quality by up to an order of magnitude and converge to a distortion floor set by the resistance modulation. We propose impedance-aware optimized pulse patterns (IA-OPP), which embed the level-dependent source impedance in the optimization objective, combined with an event-budget formulation that treats the reconfiguration rate of the communication bus as a managed resource. An exact closed-form evaluation of the piecewise-exponential load current renders the objective smooth in the switching instants. In a simulated cascaded-bridge reference system, IA-OPP attains 0.52% current total harmonic distortion (THD) at a reconfiguration rate of 2.4 kHz, outperforming nearest-level modulation, phase-shifted carrier pulse-width modulation (PWM) at up to five times the switching rate, and a classical OPP baseline at every event budget; the advantage persists across the modulation-index range and under +/-30% parameter mismatch. For three-wire star-connected systems, masking triplen orders in the objective restores the full advantage, with the impedance-aware patterns beating their linear-model counterparts by about 20% at equal budget.

0.31

Internal-Model-Control-Based Virtual Admittance Emulation for Enhanced Grid-Forming Performance

eess.SY ·2026-09-18 ·Ruzica Cvetanovic, Lazar Stojanovic, Paolo Sbabo, Paolo Mattavelli, Massimo Bongiorno
similarity 0.51
Abstract

The large-scale integration of renewable energy into electrical power systems places a growing reliance on grid-forming converters (GFMs) to overcome critical stability and control hurdles. By emulating a slowly varying voltage source behind a tunable resistive?inductive impedance, GFMs enable precise setpoint tracking and vital grid support. In this regard, virtual admittance (VA)-based inner-loop control provides exceptional flexibility in shaping the converter's small-signal immittance at connection terminals, allowing for advanced GFM functionalities. This article addresses a novel internal-model-control-based VA approach, which inherently accounts for the effects of the inner current-control loop and the voltage feedforward. Unlike the state-of-the-art VA control, the proposed VA control ensures that, at frequencies outside the influence of outer loops, the converter's terminal admittance closely matches the target admittance, which is shown to be relevant for stability. It is revealed how, with the state-of-the art VA control, a small-signal instability in the harmonic range may arise if a low-pass filter with a high cut-off frequency is used for the voltage feedforward. However, the proposed VA control ensures stable operation regardless of this cut-off frequency. The methodology is experimentally validated using a laboratory prototype that features three-phase voltage-source converters.

0.21

Characterisation of the DQsym Framework Against Harmonic State-Space and Dynamic Phasor Models for Modular Multilevel Converters

eess.SY ·2026-11-13 ·Saif Alsarayreh, Robert Dimitrovski, Aleksandra Lekic'
similarity 0.50
Abstract · Submitted to the 25th IET International Conference on AC and DC Power Transmission

Modern power systems rely on power converters that exhibit multifrequency periodic dynamics, such as modular multilevel converters (MMCs). Such converters are commonly analysed using harmonic state-space (HSS) and dynamic phasor (DP) representations. Both approaches rely on building state matrices based on the system topology, whose size grows with the number of harmonics retained in the model. This paper shows that a symmetrical direct-quadrature (dq) dynamic phasor formulation for time-domain simulation, named DQsym, has a smaller solver state matrix than HSS and DP, and whose size is independent of the truncation order K. This reduction results from evaluating harmonic coupling outside the state matrix, in the nonlinear signal blocks. The open-loop MMC model used in this paper is derived in three harmonic-domain (HD) formulations and validated against a three-phase time-domain reference model. The models are compared in terms of state-space size and sparsity, harmonic content, steady-state accuracy and eigenvalues. For truncation at K = 4, the DQsym solver has 45 states against 135 for HSS and DP, stays within about 4% of the reference, and, once closed with its coupling blocks, yields eigenvalues identical to those of HSS and DP.

0.23