CS Paper Radar

Characterisation of the DQsym Framework Against Harmonic State-Space and Dynamic Phasor Models for Modular Multilevel Converters

Saif Alsarayreh, Robert Dimitrovski, Aleksandra Lekic'

eess.SY ·submitted 2026-11-13 14:25 UTC · v1

Abstract

Modern power systems rely on power converters that exhibit multifrequency periodic dynamics, such as modular multilevel converters (MMCs). Such converters are commonly analysed using harmonic state-space (HSS) and dynamic phasor (DP) representations. Both approaches rely on building state matrices based on the system topology, whose size grows with the number of harmonics retained in the model. This paper shows that a symmetrical direct-quadrature (dq) dynamic phasor formulation for time-domain simulation, named DQsym, has a smaller solver state matrix than HSS and DP, and whose size is independent of the truncation order K. This reduction results from evaluating harmonic coupling outside the state matrix, in the nonlinear signal blocks. The open-loop MMC model used in this paper is derived in three harmonic-domain (HD) formulations and validated against a three-phase time-domain reference model. The models are compared in terms of state-space size and sparsity, harmonic content, steady-state accuracy and eigenvalues. For truncation at K = 4, the DQsym solver has 45 states against 135 for HSS and DP, stays within about 4% of the reference, and, once closed with its coupling blocks, yields eigenvalues identical to those of HSS and DP.

Comment
Submitted to the 25th IET International Conference on AC and DC Power Transmission

Closest papers

Nearest neighbours by meaning across the whole index.

Data-driven current control of modular multilevel converter-based HVDC transmission system

eess.SY ·2026-11-05 ·Victor D. Reyes Dreke, Rahul Rane, Aleksandra Lekić
similarity 0.60
Abstract · 8 pages, submitted to IET AC and DC Power Transmission (ACDC)

Model-based design (MBD) is a mature framework for designing the current controllers of modular multilevel converters (MMCs) in high-voltage direct current (HVDC) transmission systems. In MBD, linear state-space models are preferred for their good trade-off between accurate dynamics prediction and simplicity. However, first-principle derivations often neglect relevant MMC dynamics, which can hinder controller performance. Data-driven (DD) methods can deliver less biased models that capture parameter uncertainties, control-loop interactions, and grid dynamics, yet they remain under-exploited for controlling MMC currents. This paper studies DD current control method based on integral Subspace Predictive Control (iSPC), synthesized directly from input--output data measured in a high fidelity real-time digital simulator (RTDS), and proposes an initial guideline outlining the main steps for its systematic application to MMC current control. The proposed iSPC is compared against state-of-the-art DD solution, and the findings are validated through simulation studies in MATLAB/Simulink.

0.32

Harmonic Stability of Power Systems: A Control-Theoretic Definition and Assessment Criteria

eess.SY ·2026-08-20 ·N. Bhoir, A. Sarkar, J. E. Machado, J. Schiffer
similarity 0.58
Abstract

Harmonic interactions have become a defining dynamic stability phenomenon in converter-based power systems (CBPSs). However, a formalization of the notion of harmonic stability in the context of nonlinear dynamical systems is not available thus far. In this paper, we propose a definition of harmonic stability formulated as a combination of two standard stability notions, namely, bounded-input bounded-output (BIBO) and internal stability properties with respect to any nominal periodic trajectory. Moreover, we rigorously show that the local harmonic stability of any nominal periodic trajectory of nonlinear CBPSs is implied by the stability properties of its linear time-periodic (LTP) approximation. In addition, to enable computationally tractable stability assessment, we develop a framework based on harmonic state-space (HSS) representations of LTP models. In particular, we provide time-invariant linear matrix inequality (LMI) conditions to certify harmonic stability. The proposed methodology is illustrated on a grid-following converter system, where the HSS-based analysis numerically confirms harmonic stability around the periodic operating trajectory.

0.29

Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints

eess.SY ·2026-09-28 ·Xiaoying Liu, Linbin Huang, Hangyu Chen, Huanhai Xin
similarity 0.53
Abstract

Small-signal stability analysis of power electronics-dominated power systems is becoming increasingly challenging due to the large-scale integration of heterogeneous grid-following (GFL) and grid-forming (GFM) converters. Classical centralized methods, such as eigenvalue analysis and the generalized Nyquist criterion, provide direct stability assessment tools but exhibit limited scalability as the system size increases. This motivates scalable analysis methods for stability assessment and device-level diagnosis, and calls for less conservative stability conditions. To this end, this paper proposes a scalable small-signal stability assessment method with quantitative stability indices for multi-converter systems based on frequency-domain quadratic constraints (FQCs). It is shown that several existing stability conditions, including geometric conditions based on the Davis-Wielandt (DW) shell, numerical range, $x$-$z$ graph, scaled relative graph (SRG), mixed gain-phase condition, and passivity condition, are special cases of the FQC-based stability condition. This FQC-based formulation also clarifies the requirements for decentralized verification of these existing stability conditions. To further reduce conservatism, a full-multiplier FQC-based stability condition is developed, based on which an optimization problem is formulated for scalable stability certification and device-level diagnosis using quantitative stability indices without relying on graphical inspection. Combined with the mixed gain-phase condition, this optimization problem forms a hierarchical screening-diagnosis procedure that improves efficiency. Case studies demonstrate that the proposed method is less conservative than existing criteria and can effectively identify problematic devices associated with potential instability risks.

0.40

Equivalent DQ Sequence-Domain Model of Unbalanced Three-Phase Passive Elements for Power Converter Controllers

eess.SY ·2026-09-01 ·Air\án Franc\és, Luis Saz, Rafael Castillo, Dionisio Ramirez, Javier Uceda
publishedtheoryhighly cited similarity 0.53
Abstract · 8 pages, 7 figures, 2023 IEEE Applied Power Electronics Conference and Exposition (APEC)

Equivalent dq0 models of three-phase passive impedances are widely used for the design of three-phase inverter and rectifier controllers in the synchronous frame. However, these equivalent models assume that the impedance in each phase are the same, which is not always applicable. The fact that the impedance in each phase is different, generates second order harmonic content in the dq0 components, which hinders the advantages of the dq0 transformation. To avoid the second harmonic in these scenarios, it is possible to use the Fortescue's theorem to represent any asymmetrical set of three-phase signals as a linear combination of three symmetrical sequences. In the literature, only a few works have attempted to derive the equivalent model of unbalanced three-phase passive elements in the sequence domain, and none is able to account for the interaction between the zero sequence and the positive and negative sequences. This work presents the derivation of the equivalent dq sequence-domain model of unbalanced three-phase passive elements both analytically and with an intuitive graphical approach. Experimental results are shown to validate the proposed models.

0.73

An Analytical Review of Model Order Reduction Methodologies of Converter-Dominated Power Systems for Stability Studies

eess.SY ·2026-10-02 ·Goran Grdenić, Marco Fraccaro, Josipa-Pina Milišić
similarity 0.53
Abstract · 53 pages, 4 figures

The rapid integration of renewable energy sources is transforming modern electric power systems into converter-dominated networks characterized by complex multi-timescale dynamics and new stability interactions over a wide frequency range. Accurate analysis of these phenomena requires high-fidelity models of transmission networks and power electronic converters, which often result in large-scale differential-algebraic systems with significant computational burden. This paper provides an analytical review of model order reduction techniques for converter-rich power systems, with particular emphasis on the key equations employed in the reduction process. Advantages and limitations of commonly used strategies, including timescale-based singular perturbation, projection-based, operator-based, data-driven, and machine-learning based methods, are discussed. The synthesis highlights key challenges related to harmonic interactions and multi-frequency dynamics, and outlines directions for the development of computationally efficient yet dynamically accurate reduced-order models for future power systems.

0.29

Continuous-Discrete Dual-Domain Co-Design for Optimized Digital Control of Power Converters

eess.SY ·2026-11-04 ·Shen Chen, Jinjun Liu, Xuancai Zhu, Yanlong Li, Jisong Wang +4 more
benchmarktheory similarity 0.52
Abstract

Optimizing digital control for power converters typically involves designing continuous-time controllers and discretizing them via Euler, Tustin, or Generalized Bilinear Transform (GBT) methods. However, the intrinsic coupling between continuous-domain control parameters and discrete-domain implementation parameters remains underexplored, often leading to suboptimal performance. To bridge this gap, this paper first establishes a Non-Uniqueness Theorem, elucidating the coupling mechanism between dual-domain parameters. Based on this, two co-design methodologies are proposed to derive optimized parameter sets: the Explicit Frequency-Domain Analytical Method (EFDAM) and the Implicit Computer-Aided Search Method (ICASM). The EFDAM derives closed-form solutions by maximizing the crossover frequency and resonant magnitude via logarithmic frequency stability criteria, while minimizing discretization errors using Taylor-series bounds. The ICASM formulates the search for optimized parameters as a constrained multi-objective optimization problem, balancing bandwidth, resonant magnitude, and fundamental magnitude. To solve ICASM efficiently, two algorithms are introduced: the Multi-Start COBYLA (MS-COBYLA), which employs Latin Hypercube Sampling for physics-informed initialization to escape local optima, and the PSO-COBYLA hybrid algorithm, which couples global particle swarm exploration with local refinement. Experimental results on a 5-kW single-phase inverter with a Proportional-Integral-Resonant (PIR) regulator validate that the proposed methods outperform the conventional benchmark, achieving a 43.3\% reduction in the peak-to-peak current ripple measured at the zero-active-power operating point and an 11.7\%--35.9\% decrease in THDi across various harmonic profiles.

0.27

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.51
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

Impedance-Based Sensitivity Analysis for Stability Enhancement of LCC-HVDC Links Connected to Weak Grids Using Grid-Forming Converters

eess.SY ·2026-09-09 ·Luis A. Garcia-Reyes, Anup Joshi, Javier Renedo, Macarena Martin-Almenta, Oriol Gomis-Bellmunt +3 more
benchmark similarity 0.51
Abstract · Best Paper Award in the 2026 5th IEEE International Conference on Power Systems and Electrical Technology

This paper presents a frequency-domain, impedance-based sensitivity methodology for stability assessment and enhancement of line-commutated converter HVDC (LCC-HVDC) links operating under weak-grid conditions. The methodology integrates frequency-domain identification tailored for black-box systems, the Generalized Nyquist Criterion (GNC) for multivariable stability assessment, and modal impedance decomposition with participation-factor analysis to locate and interpret interaction mechanisms. The approach is validated against a detailed linearized state-space model and nonlinear EMT simulations of an LCC-HVDC benchmark. A sensitivity study varying the grid short-circuit ratio (SCR) reveals a stability limit for the standalone LCC-HVDC link and demonstrates that the integration of a grid-forming voltage source converter (GFM-VSC) substantially increases the stability margin.

0.20