Abstract

Equivalent dq0 models of three-phase passive impedances are widely used for the design of three-phase inverter and rectifier controllers in the synchronous frame. However, these equivalent models assume that the impedance in each phase are the same, which is not always applicable. The fact that the impedance in each phase is different, generates second order harmonic content in the dq0 components, which hinders the advantages of the dq0 transformation. To avoid the second harmonic in these scenarios, it is possible to use the Fortescue's theorem to represent any asymmetrical set of three-phase signals as a linear combination of three symmetrical sequences. In the literature, only a few works have attempted to derive the equivalent model of unbalanced three-phase passive elements in the sequence domain, and none is able to account for the interaction between the zero sequence and the positive and negative sequences. This work presents the derivation of the equivalent dq sequence-domain model of unbalanced three-phase passive elements both analytically and with an intuitive graphical approach. Experimental results are shown to validate the proposed models.

Comment
8 pages, 7 figures, 2023 IEEE Applied Power Electronics Conference and Exposition (APEC)
DOI
10.1109/APEC43580.2023.10131365

Closest papers

Nearest neighbours by meaning across the whole index.

Blackbox Small-Signal Modeling of Grid-Connected Inverters in Asymmetrical Power Grids

eess.SY ·2026-09-01 ·Airan Frances, Dionisio Ramirez, Javier Uceda
top venuehighly cited similarity 0.59
Abstract · 11 pages, 14 figures, IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 38, NO. 10, OCTOBER 2023

Power electronic converters are envisaged to be key enablers of modern electric power distribution systems. Grid-connected three-phase inverters are widely used in Smart Grids and microgrids, but also in standard grids. They provide controllability and dynamic decoupling capabilities, which are fundamental in the integration of renewable sources and storage systems and in specialized applications such as FACTS. Nevertheless, power electronics-based systems can exhibit dynamic interactions, which may lead to power quality issues. Although the electrical model of each element of these systems is important for their system-level analysis, they are rarely available. Blackbox modeling strategies are useful for obtaining behavioral models of commercial electronic converters. Most blackbox modeling strategies are focused on dc-dc electronic converters; however, some works have extended these concepts to three-phase converters by means of the dq framework, under the assumption of symmetrical and balanced conditions. This work proposes a new structure in the sequence domain to represent the dynamic behavior of grid-connected commercial converters in asymmetrical conditions. Experimental tests have been performed on a three-phase inverter to identify its blackbox model and its performance has been validated during an asymmetric voltage sag.

0.82

Phase-Compensated Frequency-Scan Measurement of Harmonic Transfer Function Impedance

eess.SY ·2026-10-28 ·Yiyang Liao, Yitong Li, Jinjun Liu
similarity 0.56
Abstract

Impedance models obtained through frequency scanning provides terminal characterization for small-signal stability analysis without requiring detailed knowledge of internal converter parameters. When unbalanced steady-state components introduce cross-frequency coupling, conventional $2\times2$ impedance scan methods must be extended to identify harmonic transfer function (HTF) impedance. However, the measured phases of frequency-coupling terms depend on the starting time of the fast Fourier transform (FFT) window, potentially introducing phase errors when different time references are used. This paper presents a $dq$-domain measurement method of HTF impedance that explicitly accounts for this time dependence. Phase compensation aligns the measured Fourier coefficients to a common electrical phase reference, correcting the resulting phase discrepancies and enabling consistent impedance reconstruction. Comparisons with analytical models under balanced and unbalanced conditions verify the measurement method, recovering the conventional $2\times2$ impedance and the dominant coupling blocks of a $6\times6$ HTF representation, respectively.

0.34

Decentralized Impedance Specifications for Grid-Connected Converters: a Sequence-Domain Gershgorin Method, and a Frequency-Wise Framework for Combining Different Criteria

eess.SY ·2026-11-03 ·Lazar Stojanović, Ružica Cvetanović, Paolo Mattavelli, Simone Buso
similarity 0.53
Abstract

In complex grid scenarios, with many power electronics (PE) converters connected, having specifications for converters can ease the design process. A practical approach is to impose the specifications on the converter's small-signal impedance in the frequency domain. This is advantageous since impedance is a physical property that can be measured. This paper focuses on providing decentralized impedance specifications for each converter connected to an ac bus. With decentralized specifications, each converter has its own specifications, which are independent of other converters' impedance. This enables a competitive multi-vendor environment while guaranteeing system stability. Existing methods of imposing decentralized specifications, based on the small-gain, passivity and Gershgorin theorems, are formulated within a common frequency-domain framework. Building on this, two new solutions that reduce the conservativeness of the specifications are proposed. First, Gershgorin-based decentralized specifications are formulated in the modified sequence domain. Second, a framework for combining different specification types across frequency ranges is developed and mathematically proven. The methods are compared on examples covering sub-synchronous and harmonic-range interactions of grid-following converters, grid-forming converters, and a mixed grid-forming/grid-following system, using analytical models, black-box impedance measurements, and time-domain responses obtained from simulations and an experimental setup.

0.24

Characterisation of the DQsym Framework Against Harmonic State-Space and Dynamic Phasor Models for Modular Multilevel Converters

eess.SY ·2026-11-13 ·Saif Alsarayreh, Robert Dimitrovski, Aleksandra Lekic'
similarity 0.53
Abstract · Submitted to the 25th IET International Conference on AC and DC Power Transmission

Modern power systems rely on power converters that exhibit multifrequency periodic dynamics, such as modular multilevel converters (MMCs). Such converters are commonly analysed using harmonic state-space (HSS) and dynamic phasor (DP) representations. Both approaches rely on building state matrices based on the system topology, whose size grows with the number of harmonics retained in the model. This paper shows that a symmetrical direct-quadrature (dq) dynamic phasor formulation for time-domain simulation, named DQsym, has a smaller solver state matrix than HSS and DP, and whose size is independent of the truncation order K. This reduction results from evaluating harmonic coupling outside the state matrix, in the nonlinear signal blocks. The open-loop MMC model used in this paper is derived in three harmonic-domain (HD) formulations and validated against a three-phase time-domain reference model. The models are compared in terms of state-space size and sparsity, harmonic content, steady-state accuracy and eigenvalues. For truncation at K = 4, the DQsym solver has 45 states against 135 for HSS and DP, stays within about 4% of the reference, and, once closed with its coupling blocks, yields eigenvalues identical to those of HSS and DP.

0.30

Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow

cs.ET ·2026-09-02 ·Kamini Shahare, Fei Feng, Peng Zhang
similarity 0.53
Abstract

This letter introduces Grid-Forming Three-Phase Power Flow (GFM-3PF), an augmented Newton power flow framework for modeling single-phase grid-forming inverters (GFMs) in three-phase unbalanced networks. The contributions of this work are threefold: 1) developing a two-stage solution strategy based on positive-sequence initialization followed by three-phase phase-domain lifting for robust large-scale computation; 2) incorporating phase-domain unbalanced network modeling with controlled mutual coupling together with phase-dependent, frequency-sensitive load representation; and 3) embedding a single-phase GFM bus model directly into the three-phase unbalanced Newton power flow equations through a common droop-governed frequency state. GFM-3PF is validated on 3-bus, 33-bus, and 118-bus test systems, demonstrating its accuracy, robustness, and scalability.

0.54

Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation

eess.SP eess.SY ·2026-08-30 ·Mohamed Abdalmoaty, Zheran Zeng, Dongsheng Yang, Florian Dörfler
similarity 0.52
Abstract

Cross-coupling between the $dq$ coordinates makes the identification of asymmetric grid impedances a challenging problem, particularly near the fundamental frequency where the asymmetric coupling is strongest. Existing schemes usually handle it either by perturbing the two coordinates sequentially, which lengthens the measurement, or by using a time-domain method with a global parametric model whose order must be tuned. This paper develops a single-shot active non-parametric frequency-domain method that avoids both. The equivalent impedance is parameterized by a pair of single-input single-output complex transfer functions. Each spectral line is fitted with a local rational model; the leakage and transient contributions are estimated, so that neither periodic steady-state excitation nor repeated excitation cycles are required. We give the exact finite-time discrete Fourier transform relation for the conjugate-coupled complex-signal model, and analyse the distortion that a stationary-frame filter placed ahead of the Park transform imposes on the identified pair. The method is validated on a controller hardware-in-the-loop platform against an analytically derived small-signal model, for a symmetric grid and for the same grid with an added grid-following converter that renders it asymmetric. Both complex transfer functions and all four real transfer functions of the $dq$ impedance are recovered over a wide band from a single one-second record of a random excitation, at 1 Hz resolution.

0.26

Comparative Assessment of Frequency Scans using EMT and RMS Models

eess.SY ·2026-08-27 ·Clea Bürgel, Gustavo Valverde, Gabriela Hug
similarity 0.50
Abstract

Frequency scans of inverter and grid impedances are crucial for assessing small-signal stability and system strength in inverter-dominated power systems. This paper compares frequency-scan results for several generating units, including a synchronous generator, grid-following, and grid-forming inverters, using fully dq electromagnetic transient and root-mean-square (RMS) models in Simulink. The scans are performed for the same device rating and operating point. Frequency scans and time-domain simulations show that the RMS models are valid only at low frequencies. We find that the current-controlled grid-forming inverter is more difficult to represent in RMS than the voltage-controlled grid-forming inverter. However, including the inner voltage-control loops improves the accuracy of the RMS representation. The paper also investigates the influence of generator and grid impedance on the total system impedance seen from the point of common coupling and relates the oscillatory modes and zeros of the system to peaks and dips in the first and second singular values of the system impedance, respectively.

0.22

Why Three Phases? A Historical and Engineering Reassessment of Phase Order in AC Power Transmission

eess.SY ·2026-08-27 ·Kai Sun
unusual similarity 0.50
Abstract

Three-phase alternating current is so deeply embedded in modern electric-power infrastructure that its phase order is often treated as self-evident. Historically, however, 1-phase and true 2-phase systems were commercially important, while commercial 6-phase transmission was later demonstrated. This paper reassesses why 3 phases became the dominant architecture for bulk AC transmission. A general balanced \(m\)-phase formulation is used to show that constant aggregate instantaneous power is not unique to 3 phases: an ideal balanced 2-phase system also cancels the double-frequency power term and can generate a constant-magnitude rotating field. Consequently, the historical displacement of 2 phases cannot be explained by power smoothness alone. The comparison is instead organized around conductor architecture, insulation stress, machine and transformer utilization, conversion requirements, right-of-way utilization, and technological path dependence. A historical, commercial 6-phase demonstration showed that high-phase-order transmission was technically feasible and could improve corridor utilization. The paper then asks: if PE conversion and protection make phase count less costly, could \(m>3\) offer intrinsic advantages? Six such advantages are identified: modular decomposition into interleaved 3-phase groups, redundant control degrees of freedom, structured modal/fault analysis, increased corridor power density under field constraints, potentially higher natural loading and loadability, and enhanced harmonic/field cancellation. A companion derivation shows that phase count alone does not intrinsically reduce \(I^2R\) loss at fixed total conductor material and phase voltage. As a conditional conclusion, 3 phases are an unusually favorable historical optimum for electromechanical grids, but not a mathematically universal optimum for a future converter-dominated grid.

0.27