CS Paper Radar

Continuous-Discrete Dual-Domain Co-Design for Optimized Digital Control of Power Converters

Shen Chen, Jinjun Liu, Xuancai Zhu, Yanlong Li, Jisong Wang, Shuaipo Guo, Zhipeng Song, Lijun Hang, Zeng Liu

eess.SY ·submitted 2026-11-04 04:01 UTC · v1
benchmarktheory

Abstract

Optimizing digital control for power converters typically involves designing continuous-time controllers and discretizing them via Euler, Tustin, or Generalized Bilinear Transform (GBT) methods. However, the intrinsic coupling between continuous-domain control parameters and discrete-domain implementation parameters remains underexplored, often leading to suboptimal performance. To bridge this gap, this paper first establishes a Non-Uniqueness Theorem, elucidating the coupling mechanism between dual-domain parameters. Based on this, two co-design methodologies are proposed to derive optimized parameter sets: the Explicit Frequency-Domain Analytical Method (EFDAM) and the Implicit Computer-Aided Search Method (ICASM). The EFDAM derives closed-form solutions by maximizing the crossover frequency and resonant magnitude via logarithmic frequency stability criteria, while minimizing discretization errors using Taylor-series bounds. The ICASM formulates the search for optimized parameters as a constrained multi-objective optimization problem, balancing bandwidth, resonant magnitude, and fundamental magnitude. To solve ICASM efficiently, two algorithms are introduced: the Multi-Start COBYLA (MS-COBYLA), which employs Latin Hypercube Sampling for physics-informed initialization to escape local optima, and the PSO-COBYLA hybrid algorithm, which couples global particle swarm exploration with local refinement. Experimental results on a 5-kW single-phase inverter with a Proportional-Integral-Resonant (PIR) regulator validate that the proposed methods outperform the conventional benchmark, achieving a 43.3\% reduction in the peak-to-peak current ripple measured at the zero-active-power operating point and an 11.7\%--35.9\% decrease in THDi across various harmonic profiles.

Closest papers

Nearest neighbours by meaning across the whole index.

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.56
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.54

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.54
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints

eess.SY ·2026-09-28 ·Xiaoying Liu, Linbin Huang, Hangyu Chen, Huanhai Xin
similarity 0.54
Abstract

Small-signal stability analysis of power electronics-dominated power systems is becoming increasingly challenging due to the large-scale integration of heterogeneous grid-following (GFL) and grid-forming (GFM) converters. Classical centralized methods, such as eigenvalue analysis and the generalized Nyquist criterion, provide direct stability assessment tools but exhibit limited scalability as the system size increases. This motivates scalable analysis methods for stability assessment and device-level diagnosis, and calls for less conservative stability conditions. To this end, this paper proposes a scalable small-signal stability assessment method with quantitative stability indices for multi-converter systems based on frequency-domain quadratic constraints (FQCs). It is shown that several existing stability conditions, including geometric conditions based on the Davis-Wielandt (DW) shell, numerical range, $x$-$z$ graph, scaled relative graph (SRG), mixed gain-phase condition, and passivity condition, are special cases of the FQC-based stability condition. This FQC-based formulation also clarifies the requirements for decentralized verification of these existing stability conditions. To further reduce conservatism, a full-multiplier FQC-based stability condition is developed, based on which an optimization problem is formulated for scalable stability certification and device-level diagnosis using quantitative stability indices without relying on graphical inspection. Combined with the mixed gain-phase condition, this optimization problem forms a hierarchical screening-diagnosis procedure that improves efficiency. Case studies demonstrate that the proposed method is less conservative than existing criteria and can effectively identify problematic devices associated with potential instability risks.

0.40

Characterisation of the DQsym Framework Against Harmonic State-Space and Dynamic Phasor Models for Modular Multilevel Converters

eess.SY ·2026-11-13 ·Saif Alsarayreh, Robert Dimitrovski, Aleksandra Lekic'
similarity 0.52
Abstract · Submitted to the 25th IET International Conference on AC and DC Power Transmission

Modern power systems rely on power converters that exhibit multifrequency periodic dynamics, such as modular multilevel converters (MMCs). Such converters are commonly analysed using harmonic state-space (HSS) and dynamic phasor (DP) representations. Both approaches rely on building state matrices based on the system topology, whose size grows with the number of harmonics retained in the model. This paper shows that a symmetrical direct-quadrature (dq) dynamic phasor formulation for time-domain simulation, named DQsym, has a smaller solver state matrix than HSS and DP, and whose size is independent of the truncation order K. This reduction results from evaluating harmonic coupling outside the state matrix, in the nonlinear signal blocks. The open-loop MMC model used in this paper is derived in three harmonic-domain (HD) formulations and validated against a three-phase time-domain reference model. The models are compared in terms of state-space size and sparsity, harmonic content, steady-state accuracy and eigenvalues. For truncation at K = 4, the DQsym solver has 45 states against 135 for HSS and DP, stays within about 4% of the reference, and, once closed with its coupling blocks, yields eigenvalues identical to those of HSS and DP.

0.30

Generalized Frequency-Domain Stability Analysis Formulation for Multi-Terminal HVDC Systems

eess.SY ·2026-11-05 ·Francisco J. Cifuentes Garcia, Thomas Roose, Luis Müller, Jef Beerten
code/data similarity 0.51
Abstract · Under review (10 pages). For the associated packages visit http://github.com/Electa-Git/PowerImpedance.jl and http://github.com/Electa-Git/Z…

The integration of offshore wind farms (OWFs) and the interconnection of different transmission networks are key drivers for multi-terminal DC (MTDC) systems. Bipolar high-voltage direct current (HVDC) employing dedicated metallic return (DMR) are attractive due to their increased availability, which co-exist with monopolar and rigid bipole configurations. While existing works focus on symmetric operation and particular configurations, we present a unified framework for MTDC stability analysis valid for both symmetric and asymmetric conditions. The formulation uses the minimum number of variables without loss of information, and combines the analytical network representation with black-box converter models, thereby enabling sensitivity studies. In addition, a closed-form expression guiding the stability improvement is presented, which requires minimal data exchange between involved parties. The framework is demonstrated on several case studies of increasing complexity, which highlight the importance of considering intra-station converter couplings and possible uncertainty of network parameters.

0.44

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.50
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36

Robust Data-Driven Controller Synthesis from Sampled and Uncertain Frequency Response Estimates using Integral Quadratic Constraints

eess.SY ·2026-10-14 ·Luuk Marceau Spin, Maurice W. P. M. H. Heemels, Nathan van de Wouw, Roland Toth
similarity 0.49
Abstract · 15 pages, 6 figures, none other publications

In this paper, we develop a novel MIMO controller synthesis method that relies solely on frequency-domain data of discrete-time systems. The approach is based on an iterative design procedure using \emph{integral quadratic constraints} (IQCs). It generalizes existing data-driven methods that approximate semi-infinite IQC conditions by enforcing them on a finite set of measured frequency points. Such approximations do not provide guarantees on the continuous frequency axis and may fail to capture inter-frequency behavior. We address this limitation by formulating a convex optimization problem that preserves robustness guarantees over the entire frequency range. In particular, the proposed method explicitly accounts for inter-frequency behavior of both plant and controller, leading to certified robust stability and performance. The effectiveness and computational efficiency of the approach are demonstrated using experimentally obtained frequency response data from industrial-grade semiconductor equipment. The synthesized controller is implemented on the physical setup, and its performance is validated in real-time experiments.

0.35

Decentralized Impedance Specifications for Grid-Connected Converters: a Sequence-Domain Gershgorin Method, and a Frequency-Wise Framework for Combining Different Criteria

eess.SY ·2026-11-03 ·Lazar Stojanović, Ružica Cvetanović, Paolo Mattavelli, Simone Buso
similarity 0.48
Abstract

In complex grid scenarios, with many power electronics (PE) converters connected, having specifications for converters can ease the design process. A practical approach is to impose the specifications on the converter's small-signal impedance in the frequency domain. This is advantageous since impedance is a physical property that can be measured. This paper focuses on providing decentralized impedance specifications for each converter connected to an ac bus. With decentralized specifications, each converter has its own specifications, which are independent of other converters' impedance. This enables a competitive multi-vendor environment while guaranteeing system stability. Existing methods of imposing decentralized specifications, based on the small-gain, passivity and Gershgorin theorems, are formulated within a common frequency-domain framework. Building on this, two new solutions that reduce the conservativeness of the specifications are proposed. First, Gershgorin-based decentralized specifications are formulated in the modified sequence domain. Second, a framework for combining different specification types across frequency ranges is developed and mathematically proven. The methods are compared on examples covering sub-synchronous and harmonic-range interactions of grid-following converters, grid-forming converters, and a mixed grid-forming/grid-following system, using analytical models, black-box impedance measurements, and time-domain responses obtained from simulations and an experimental setup.

0.24