CS Paper Radar

Impedance-Aware Optimized Pulse Patterns for Reconfigurable Battery Systems

Julian Estaller, Johannes Buberger, Andreas Wiedenmann, Wolfgang Grupp, Tobias Hoegerl, Thomas Weyh

eess.SY ·submitted 2026-09-15 08:29 UTC · v1

Abstract

Reconfigurable battery systems (RBS) synthesize the converter output voltage by inserting and bypassing battery cell groups, so every switching state changes not only the source voltage but also the source impedance. This paper shows that this configuration-dependent impedance breaks a tacit assumption of optimized pulse patterns (OPP): patterns designed with the customary linear plant model overestimate their achievable current quality by up to an order of magnitude and converge to a distortion floor set by the resistance modulation. We propose impedance-aware optimized pulse patterns (IA-OPP), which embed the level-dependent source impedance in the optimization objective, combined with an event-budget formulation that treats the reconfiguration rate of the communication bus as a managed resource. An exact closed-form evaluation of the piecewise-exponential load current renders the objective smooth in the switching instants. In a simulated cascaded-bridge reference system, IA-OPP attains 0.52% current total harmonic distortion (THD) at a reconfiguration rate of 2.4 kHz, outperforming nearest-level modulation, phase-shifted carrier pulse-width modulation (PWM) at up to five times the switching rate, and a classical OPP baseline at every event budget; the advantage persists across the modulation-index range and under +/-30% parameter mismatch. For three-wire star-connected systems, masking triplen orders in the objective restores the full advantage, with the impedance-aware patterns beating their linear-model counterparts by about 20% at equal budget.

Comment
11 pages, 6 figures. Submitted to the IEEE Open Journal of Power Electronics

Closest papers

Nearest neighbours by meaning across the whole index.

Communication Delay Robust Control of BESS for AI Training Load Smoothing

eess.SY ·2026-09-18 ·Xue Lyu, Wei Du, Sheik Mohammad Mohiuddin, Brett A. Ross
hot direction similarity 0.56
Abstract · 10 pages, 17 figures

AI training loads can exhibit rapid power fluctuations because their power demand differs significantly between computational and communication phases, creating challenging ramp rates at the data center point of common coupling (PCC). Integrating battery energy storage systems (BESS) in data centers is a promising mitigation option. This paper proposes a hybrid BESS control strategy that combines droop-based grid-forming (GFM) control with instantaneous load current-based compensation to suppress high frequency load fluctuations. The GFM control loop regulates the long-term power exchange of the BESS, while the load-following control provides fast compensation for short-term AI workload fluctuations. Communication delay between the load current measurements and the BESS controller is explicitly modeled, and its impact on smoothing performance is analyzed. To mitigate delay-induced degradation, a predictor-based compensation method is incorporated into the BESS control structure. High-fidelity electromagnetic transient simulations are conducted to validate the proposed approach. Results demonstrate effective smoothing of AI training load fluctuations across different grid strength conditions and under time varying communication delays.

0.28

Supporting Data Center Grid Integration via Co-Optimized Battery Energy Storage Sizing and Capacity Allocation

eess.SY math.OC ·2026-11-06 ·Wei Wang, Himanshu Sharma, Thiagarajan Ramachandran
similarity 0.55
Abstract

Interconnecting large data centers can be delayed by grid requirements on demand flexibility, ramping limits, and ride-through performance. This paper proposes an optimization-based framework to size a Battery Energy Storage System (BESS) that accelerates data center grid integration by providing BESS capacity required to meet selected flexibility and grid-support requirements. The model co-optimizes BESS power rating and energy capacity while allocating capability across three services: (i) demand response over a specified duration, (ii) mitigation of high-magnitude, high-frequency load fluctuations through reserved active power with zero net state-of-charge change, and (iii) voltage support via reactive power capability at the point of common coupling. Minute-level operational scheduling enforces state-of-charge feasibility and load ramp constraints, and incorporates a controllable queue of delay-insensitive computing tasks to enhance flexibility. A case study using a real data center load profile demonstrates the proposed method and quantifies the BESS power-energy requirements and operational trade-offs needed to satisfy the multi-service constraints, providing practical guidance for interconnection planning and deployment.

0.05

Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing

eess.SY ·2026-09-03 ·Xin Chen
similarity 0.53
Abstract

To facilitate the grid-friendly integration of highly variable AI data center loads, this paper proposes a grid-mode-aware model predictive control (G-MPC) framework for managing a hybrid energy storage system (HESS) to smooth grid-side power demand. The framework optimally coordinates a battery energy storage system (BESS) and a supercapacitor (SC) by solving a multi-step optimization problem in a receding-horizon manner. In particular, band-pass filter dynamics are directly embedded in the G-MPC formulation to extract and suppress grid-side power components associated with vulnerable grid oscillatory modes, thus mitigating load-induced grid oscillations. The resulting G-MPC optimization jointly minimizes violations of grid-side power-envelope, ramp-rate, and modal-power requirements and the degradation and power-ramping costs of the BESS and SC, while satisfying power limits, state-of-charge limits, and other operational constraints. To enable real-time implementation, a fix-and-re-optimize algorithm is developed to solve each G-MPC problem efficiently while preventing simultaneous charging and discharging. Extensive simulations demonstrate the effectiveness, flexibility, and computational efficiency of the proposed framework. The results also highlight the importance of explicitly suppressing power components associated with vulnerable grid modes, rather than merely reducing overall load variations, to effectively mitigate grid oscillations.

0.40

Low-Voltage Ride-Through in AI Data Centers via Coordinated Battery and Computing Load Control

eess.SY ·2026-11-14 ·Xiaoyang Wang, Xin Chen, Fang Chen Lin, Prasad Enjeti, Ali Yazdanpanah +2 more
hot direction similarity 0.52
Abstract · 5 pages, 7 figures

The ability of large AI data centers to ride through grid voltage sags is critical to power system stability and reliability. This paper frames data center low-voltage ride-through (LVRT) as a DC-link power balance problem. Once the rectifier reaches its current limit, the power drawn from the grid decreases in proportion to the grid voltage. The DC-link capacitor can supply the resulting power deficit only briefly before the DC-link voltage falls low enough to trigger undervoltage protection tripping. To address this issue, this paper proposes effective control strategies for coordinating uninterruptible power supply (UPS) battery and computing load curtailment to offset the power deficit and enable LVRT at minimum control cost. Three control scenarios are studied: UPS battery support alone, computing load curtailment alone, and the coordinated use of both resources. Electromagnetic transient (EMT) simulations using the TAMU-ERCOT AI data center model demonstrate that battery support and the coordinated strategy achieve LVRT for all tested sags, including a near-zero-voltage fault, while load curtailment alone rides through moderate voltage sags.

0.22

RFSR-MI-MPC: Ranking-Based Feasible-Set Restriction for Real-Time Control of Reconfigurable Battery Packs

eess.SY ·2026-09-25 ·Albert Škegro, Quan Ouyang, Torsten Wik, Changfu Zou
similarity 0.52
Abstract · Submitted to IEEE Transactions on Control Systems Technology. 15 pages, 4 figures. Code: https://doi.org/10.5281/zenodo.22136253; data: http…

A ranked-prefix feasible-set restriction is proposed for real-time mixed-integer model predictive control of series-connected reconfigurable battery packs with per-cell bypass switching. Cells are ordered at each sampling instant by a one-step objective-informed suitability score, and the engagement variables are constrained to prefixes of that ordering. The restriction reduces the number of admissible per-step engagement patterns from combinatorial to linear in the number of cells while leaving the model, objective, and physical constraints unchanged. For a 20-cell pack driven over a worldwide harmonized light vehicles test cycle, the proposed controller certifies every active step, solves every instance without branching, and reduces the 95th-percentile solver time by a factor of 6.8 relative to the full subset-selection controller. The cycle-mean cell-to-cell state-of-charge standard deviation decreases by a factor of 3.4, and no power curtailment occurs. Same-state reference solves show a mean restriction gap below 0.11% on jointly certified steps, and the computational gains persist across the tested initial conditions, cell heterogeneity levels, pack sizes, and prediction horizons without retuning.

0.38

Coordinated Conservation Voltage Reduction and Network Topology Reconfiguration in Active Distribution Networks

eess.SY ·2026-10-12 ·Rida Fatima, Hassan Zahid Butt, Xingpeng Li
similarity 0.51
Abstract

Distribution networks rely on conservation voltage reduction (CVR) and network topology reconfiguration (NTR) to manage demand, distributed energy resources (DERs), and tighter operating margins. Yet these strategies are typically deployed independently, despite coupled effects on feeder voltages, losses, and loading. This paper addresses that gap by developing a day-ahead mixed-integer second order cone programming (MISOCP) framework that jointly optimizes feeder head voltage control and network reconfiguration. The formulation incorporates AC branch flow constraints, ZIP load models, DERs, battery energy storage systems, and multi substation radiality. Using modified IEEE 33 bus and 123 bus systems, four configurations isolate the individual and coordinated effects of CVR and NTR. On the 33-bus system under mixed ZIP loading, NTR reduces active energy loss by 2.50%, while coordinated operation reduces it by 2.91% relative to SDN and produces a 2.46% CVR induced active load reduction relative to SDNTR. Under constant impedance loading, coordinated operation reduces active energy loss by 17.65% relative to SDN, while CVR reduces active load by 14.61% relative to SDNTR. DER portfolio scaling shows a nonmonotonic coordinated load reduction response, strongest at 20% penetration and decreasing at higher levels. On the 123 bus system, NTR reduces losses by 19.3%, while CVR reduces voltage dependent load energy by 2.3 to 2.4%. Under loading stress, SDN becomes infeasible at 120% loading, whereas CEDNTR remains feasible. Overall, the results demonstrate complementary, operating condition dependent benefits shaped by load composition, DER portfolio scaling, feeder topology, voltage margins, and source constraints, highlighting the value of joint optimization.

0.29

Improved Single-Input Space Vector for DC-Biased Sinusoidal Current Control in Battery Cyclers

eess.SY ·2026-11-12 ·Manveer Aujla, Philip Lewoc, Harminderjit S. Toor, Ahmad Ali, Caniggia Viana +1 more
publishedunusual similarity 0.51
Abstract · 8 pages, 17 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

This paper presents improvements to the single-input space vector (SISV) concept for current control in a battery cycler based on a two-phase interleaved buck converter. The cycler is controlled to output a dc-biased sinusoidal current, enabling investigation of second-harmonic ripple effects on lithium-ion cell aging. A modified SISV generation scheme is introduced to track current references containing both dc and sinusoidal components, and an impedance-angle compensation method is proposed to decouple the d and q control axes without disturbing dc tracking. A dq phase-portrait visualization method is also introduced to evaluate transient performance for both SISV and proportional-integral-resonant (PIR) control methods. Simulation and experimental results validate dc-biased sinusoidal current tracking using PIR control and SISV control with different decoupling schemes. The phase-portrait framework allows for straightforward evaluation of transient performance for both SISV and PIR control methods and supports controller tuning to obtain desired trajectories. The results demonstrate the feasibility of SISV-based current control as an alternative to PIR control for battery-cycler applications. The proposed improvements support the development of battery cyclers capable of controlling both dc and sinusoidal current components.

0.36

Co-Optimization of Scheduling, Control, and Incentivization of Electric Vehicles for Improving Power System Stability

eess.SY ·2026-10-10 ·Amit Kumer Podder, Tomonori Sadamoto, Aranya Chakrabortty
similarity 0.50
Abstract

We present a finite-horizon, greedy heuristic-based co-optimization and optimal control framework that jointly determines the optimized charging rates, charging times, and an optimal charging control law for electric vehicles (EVs) to improve both voltage stability and small-signal dynamic performance of a power distribution system. The proposed strategy encourages EV drivers to be flexible in choosing their charging rates and times through monetary incentivization under a fixed budget. The design is validated using the IEEE 33-bus distribution system model with ten EV charging stations (EVCSs). Results show that incentivizing drivers to settle for lower charging rates, implemented by a wait-and-save strategy, and rescheduling their charging times strategically can significantly improve the voltage stability index (VSI) of the system as well as the damping factors for the mid-frequency oscillation modes seen in the DC-link bus voltage.

0.20