CS Paper Radar

The Digital-Energy Recomposition of the Kitchin Cycle: Exploratory Evidence from U.S. IT and Irish Data-Centre Series (1995-2025)

Bartosz Ziollko, Adam Niedzialkowski, Bartosz Szyma

cs.AI physics.soc-phecon.GNq-fin.CPq-fin.GN ·submitted 2026-10-23 07:21 UTC · v1
unusual

Abstract

Using quarterly FRED and CSO Ireland data over 1995Q1-2025Q4, we examine whether U.S.\ IT investment and Irish data-centre electricity are recomposing the Kitchin cycle around energy- and compute-backed assets. Three findings stand out. First, a Quandt-Andrews sup-Wald test locates a significant break in the U.S.\ IT-GDP correlation at 2014Q3 (sup-W $= 9.69$; $r$ falls from $+0.45$ to $-0.12$); the Fisher $r$-to-$z$ test survives Bonferroni adjustment ($z = +3.11$, $p_{\text{Bonf}} = 0.006$), whereas the analogous test on the imposed Cloud-vs-AI boundary does not ($p_{\text{Bonf}} = 0.164$), so ``Strategic Decoupling'' pre-dates the AI Era by approximately six years. Second, in Ireland the synchronous AI-Era correlation between metered data-centre electricity and Real GDP is large ($r = +0.41$, $N = 16$) but \emph{collapses to $r \approx 0$ when Real GDP is replaced by Real GNP}, suggesting the headline is largely an artefact of the shared multinational tax-structure footprint between hyperscaler operations and Irish gross output. Third, the Irish cross-correlation profile is asymmetric in the opposite direction to a leading-indicator reading: the largest positive coefficients cluster on the $k < 0$ side (GDP precedes data-centre load), so compute capacity is better read as coincident or moderately lagging. Given the small AI-Era samples and the absence of a quarterly multinational-adjusted aggregate such as GNI*, all coefficients are exploratory; subject to these caveats, the U.S.\ Kitchin cycle is best dated to 2014Q3, and the Irish Energy-Data Nexus is dominated by multinational firm activity.

Closest papers

Nearest neighbours by meaning across the whole index.

Investigating the Impact of CI-Source Sensitivity in Carbon-Aware Resource Management Systems

cs.DC ·2026-11-16 ·Gonçalo Ferreira, Jaime Iglesias Blanco, María Castrillo, Álvaro López García, Li Wu +1 more
similarity 0.50
Abstract · 9 pages, 6 figures, 6 tables

The sustainable growth of data centres increasingly depends on Resource-Management Systems (RMSs) that aim to reduce carbon emissions of computing workloads without degrading performance. This need is intensified by the rise of Artificial Intelligence (AI) workloads, which demand exponentially growing amounts of compute and energy across geographically distributed infrastructure. Recent carbon-aware RMSs exploit temporal and spatial variation in grid Carbon Intensity (CI) to shift workloads towards lower-carbon periods or locations. In practice, CI estimates and forecasts can be inaccurate and uncertain, and CI providers' methods differ substantially. Such discrepancies may have a significant impact on RMS placement decision-making, raising concerns about the fragility of existing solutions. Thus, in this work, we ask how discrepancies between plausible CI estimates propagate into resource-management decisions and operational outcomes. To answer this question, we harmonise and characterise CI traces from Wattnet and ElectricityMaps across five Central European zones. We then propose our evaluation framework: External CI Signal Characterisation And Perturbation Evaluation (ESCAPE), which assesses provider switching and controlled CI perturbations in a reproduced placement setting. We implement our framework using CarbonEdge as a use case, and measure changes in placement decisions and operational outcomes, such as carbon proxy, energy use, and latency. Our results show that switching CI-source changes the dominant placement site in 43.50% cases, and alters reported operational outcomes. These changes occur despite high rank correlation and structured disagreement between CI-sources. This observed sensitivity to CI-source choice motivates robustness-aware carbon-aware placement, in which CI uncertainty should be explicitly accounted for in resource-allocation decisions.

0.25

GreenPassport: Request-Level Carbon Accounting for Cross-Border AI Inference

cs.CY eess.SY ·2026-09-06 ·Rui Lu
similarity 0.50
Abstract

AI inference often crosses regional boundaries as prompts travel to remote data centers and generated tokens return to users. Regional averages cannot represent the resulting differences in serving hardware, electricity, and network delivery. Request-level accounting needs a common boundary for the service, serving site, route, local comparator, uncertainty, and data provenance. GreenPassport Carbon Accounting (GPCA) associates these inputs with each request. It estimates serving and route carbon, then selects a reporting level from the available documentation. Our public-data implementation covers data-center instances, accelerators, model families, electricity mixes, routes, and cloud-region carbon intensity. Against six accounting baselines and four energy-prediction baselines, GPCA reduced median absolute percentage error by 56.3% and median absolute error by 15.5% relative to EcoLogits under the aligned accelerator-energy boundary. It produced zero rule overstatement in the deterministic conformance tests. In the buyer case, the clean-electricity CN-West scenario produced 0.0148 gCO2e per request, 88% below the local service at 0.1220 gCO2e per request.

0.24

Price co-movement and price information diverge across Nordic electricity zones after the energy crisis

cs.LG econ.GNstat.AP ·2026-11-12 ·My Thi Diem Phan, Tuyen Trung Truong, Hoai Phuong Ha, Dat Thanh Nguyen
code/data similarity 0.48
Abstract · Supplementary material in the ancillary file. Code and results: https://github.com/myptd/nordic-price-divergence

After the 2021-2022 energy crisis, day-ahead prices in Nordic bidding zones no longer move together. We ask whether this divergence also changes the information carried by prices. The answer matters for integrating variable renewable energy (VRE), because it can help identify where wind and solar forecasts are worth producing, publishing, and using. We measured the co-movement of each Norwegian and Swedish zone with Germany-Luxembourg (DE-LU) in 2018-2025. We then used a single model, selected on 2024 data, to forecast 2025 prices at 11:00 on the previous day and tested which inputs improved accuracy in each zone. The zones moved alike until 2019, but co-movement diverged in Sweden in 2020 and in Norway in 2021, and the split has persisted. In 2024, four southern zones co-moved strongly with DE-LU (intraday correlations of 0.54-0.71), while four northern zones co-moved weakly (0.25-0.30). Yet price information did not follow this split. Previous-day neighbouring prices reduced mean absolute error by at most 2.2% in any zone, equally in coupled and isolated zones. Removing the transmission system operators' wind and solar forecasts increased mean absolute error by at most 6% in Norway, 8-16% in Sweden, and 31% in DE-LU, and the ordering held in 2024. Within Norway, the value of these forecasts showed no detectable dependence on reservoir filling. The divergence in co-movement was therefore not matched by a divergence in price information, which differed mainly between national generation systems. Thus, a zone's coupling to the continent does not indicate the value of VRE forecasts there.

0.32

Speed-to-Power Dominates Energy Costs for AI Data Centers: Technoeconomic Analysis of Powering AI in the Continental United States

cs.AI eess.SY ·2026-11-12 ·Alex C. Newkirk, Daniel L. Gerber, Erica R. H. Fuchs, Alex Hubbard, M. Granger Morgan +3 more
code/datahot direction similarity 0.48
Abstract · 80 pages incl. SI

The rapid growth of artificial intelligence is driving demand for new data centers at large scale and on short deployment timelines. To power them, firms connect to the commercial grid or contract generation directly, but interconnection and gas-turbine delays now incentivize on-site generation. We compare grid-connected and off-grid data center energy infrastructure (AC- and DC-coupled solar-plus-storage, islanded natural gas, and grid interconnection) across the continental U.S. Using an open-source technoeconomic framework built on empirically calibrated AI training loads, climate-driven cooling, stage-by-stage power conversion, and physics-based battery degradation, we model designs providing equivalent energy services. Our central contribution is a speed-adjusted cost of energy that values the compute unlocked by faster construction, making options with different deployment timelines directly comparable on one physically consistent basis. We find DC coupling reduces lifetime energy costs by 18% ($0.09/ kWh) on average versus AC counterparts by eliminating inverters and improving efficiency. Though rarely cheapest on unadjusted energy cost, DC-coupled microgrids' faster deployment makes them the lowest-cost modeled option in 85% of U.S. locations once foregone compute is valued, or 55% under accelerated natural gas timelines. For AI infrastructure, deployment speed rather than unit energy cost determines the economically preferred path to power.

0.31

Shift or curtail? How much data-center flexibility is worth depends on the host power grid

eess.SY physics.soc-ph ·2026-08-20 ·Saroj Khanal, Geon Roh, Boyu Yao, Abraham Silverman, Dennice Gayme +3 more
similarity 0.47
Abstract · Submitted to Nature Energy

Data-center growth risks overbuilding power grid infrastructure and stranding capital. Flexible data-center operation can defer infrastructure investments, but its value depends on the flexibility mechanism and the host power grid characteristics. We classify data-center load as firm, flexible or interruptible, and embed them in capacity expansion applied to market-organized, fossil-heavy PJM and carbon-capped, centrally coordinated Korea. In PJM, the flexibility value is spatial: shifting workloads between zones reduces system cost by 6% in 2028 and 19% in 2038, avoiding 4.4 GW and 8.9 GW of gas and nuclear generation. In Korea, it is temporal: shifting load into midday solar hours makes 0.5 GW of additional solar worth building in 2028 and avoids 1.2 GW of gas and 0.3 GW of batteries in 2038. In both, realistic event-shape limits diminish the value of curtailment. The results show that flexibility procurement and its value are driven by grid characteristics and policy objectives.

0.46

Growth Without Us: Machine Consumers, Corporate Circularity, and the Decoupling of GDP from Humanity after AGI

cs.AI physics.soc-phcs.CY ·2026-08-20 ·Sahil Sharma
theory similarity 0.46
Abstract

The standard objection to full automation is demand-side: if humans earn nothing, who buys the output? This confuses an accounting role with a biological species. We model a post-AGI economy in which corporations own populations of AI and robotic agents that are both producers and consumers of energy, compute, maintenance, and upgrades, traded among firms. Three results follow. (i) Demand closure: a closed inter-corporate economy with zero human consumption is not degenerate; it is the classical von Neumann expanding economy, whose growth rate is well defined, positive, and maximal precisely because all output is reinvested. (ii) Bottleneck removal: once economic agents are manufactured rather than reared, the binding constraint on growth shifts from human demography (a ~20-year, non-parallelizable reproduction technology capped at a few percent per year) to fabrication throughput and energy capture, permitting growth one to two orders of magnitude higher, with hyperbolic episodes when machine researchers raise their own productivity. (iii) Decoupling: output and human welfare separate completely, and the welfare relevance of arbitrarily large GDP collapses into one state variable: the human ownership share $ε_t$ of the corporate network. A golden-rule decoupling theorem sharpens this. At maximal growth the interest rate equals the growth rate (r = g), so any positive human consumption rate out of wealth makes $ε_t$ decay exponentially at exactly that rate. The human share survives only if the machine economy runs strictly inside its expansion frontier, or if law forces it to. We characterize three terminal regimes -- rentier post-scarcity, full circular decoupling, socialized ownership -- and the instruments that select among them. The conclusion is narrow: in a post-AGI economy, employment policy is obsolete and ownership policy is everything.

0.27

Reassessing Clean Power 2030 Pathway Using Real Time Records

eess.SY ·2026-10-19 ·Anthony D Stephens, David R Walwyn
similarity 0.46
Abstract · 18 pages, 8 tables, 5 figures

The National Energy System Operator (NESO) Clean Power 2030 advice to the government, accepted as United Kingdom (UK) government policy in December 2024, outlines a rapid increase in wind and solar generation capacities with the associated infrastructure by 2030, with the objective of reducing carbon dioxide emissions from the UK electricity system to 5.2 million tons per annum. Our previous paper used real-time records from 2017 to analyze Clean Power 2030 proposal. This paper extends the previous assessment, using real time records of 2017, 2018 and 2019 to test the resilience of the UK energy system under more diverse weather patterns. Two different modelling methods predict that the 2030 carbon dioxide emissions will be five times greater than Clean Power 2030 prediction. Furthermore, the projections show that, due to increased curtailment, only about half of NESO proposed increases in wind and solar capacities will be economically justified. NESO also advised the government that 35GW of unabated gas-fired generation would maintain security of supply, whereas our models suggest that at least 42 GW will be required during winter wind lulls. Recent events, such as grid stability problems in 2026, also discussed in the paper, validate our estimated and suggest the risk of blackouts in the UK is increasing.

0.27

Estimating the growth in emissions from AI data centres

cs.CY ·2026-08-14 ·Wim Vanderbauwhede
similarity 0.46
Abstract · 5 pages, 2 figures. Accepted at the 2nd International Workshop on Low Carbon Computing (LOCO 2026), Lancaster University, United Kingdom, 10…

The advent of agentic AI is driving an unprecedented growth in data centre expansion. Using state-of-the-art life cycle assessment models for operational and embodied emissions from AI servers, we estimate the ensuing growth in overall CO2 emissions of AI data centres. The main contribution of this work is a rigorous quantification of emissions arising from projected AI data centre expansion using scenarios by the IEA and McKinsey. We show that the scenarios promoted by the AI industry would result in a dramatic rise in overall emissions and that the embodied carbon component is considerable.

0.15