Abstract

Digitally controlled water distribution systems must maintain service during disruptions, yet restoring water delivery does not necessarily ensure hydraulic recovery. This study evaluates cyber-induced pump outages under hypothetical environmental operating stress using two EPANET benchmark networks (Net1 and Net3) simulated with the Water Network Tool for Resilience. The experimental design comprises 288 simulation records (240 distinct configurations), including 192 verified attack scenarios, with four- and twelve-hour outages, six hydraulic configurations, and four mitigation strategies. All attack scenarios satisfied pump-shutdown verification and pre-attack hydraulic-equivalence criteria. Twelve-hour outages produced an average of 404.96 m$^3$ of unmet demand in Net1, while Net3 maintained full modeled demand delivery despite pressure deviations. Sustained pressure recovery occurred in 103 of 192 scenarios, with 65 exhibiting subsequent relapse, whereas all scenarios satisfied the post-outage water-service recovery criterion. Combined mitigation eliminated unmet demand in evaluated Net1 scenarios, while outage shortening achieved the highest sustained-pressure-recovery count. These findings highlight network-dependent resilience and the distinction between service restoration and hydraulic recovery. Environmental stress scenarios represent sensitivity assumptions rather than empirically calibrated climate impacts.

Closest papers

Nearest neighbours by meaning across the whole index.

Closing the Applied Cybersecurity Gap in Critical Infrastructure: A Cyber-to-Physical Security Assessment Framework for Water Systems

cs.CR ·2026-10-29 ·Halil Dursunoglu, Kaan Sulkalar
similarity 0.63
Abstract

The integration of information technology and operational technology in water infrastructure creates pathways through which cyber compromise may affect physical service delivery. This study revisits the Applied Cybersecurity Gap (ACG) framework by evaluating an experimental Applied Cybersecurity Gap Index (ACGI) alongside the Cyber-to-Physical Propagation Rate (CPPR), defined as the proportion of initially compromised trials that produce a specified physical-impact outcome. The expanded evaluation comprises 2,160 synthetic trials across three water-network benchmarks, including EPANET Example Network 3 (Net3), and couples declared cyber-attack progression rules with hydraulic simulations. A source-trained machine-learning model evaluated on 247 compromised Net3 trials achieved ROC-AUC 0.772, PR-AUC 0.775, and F1 0.733, compared with 0.661, 0.642, and 0.704 for a scenario-only baseline. The configuration-cluster bootstrap interval for the ROC-AUC difference was 0.038--0.183. A separate 720-run Net3 hydraulic operating-point sensitivity analysis achieved the study's exploratory baseline pressure criterion in all reruns, preserved 717 of 720 physical-impact labels, and produced ROC-AUC 0.791 with the frozen source-trained model. Additional analyses examine the sensitivity of CPPR to the physical-impact threshold and assumed control-blocking probabilities, and demonstrate that the ACGI--CPPR association is partly induced by the simulation design rather than independently validated. The findings establish a reproducible simulation-based assessment workflow, but do not constitute field calibration of cybersecurity-control effectiveness or prediction of real-world utility incidents.

0.32

Economic Impact Assessment of Denial-of-Service and Time-Delay Attacks on Advanced Metering Infrastructure

eess.SY cs.CR ·2026-08-10 ·Lais Oliveira Krohl, Saurav Basnet, Ioannis Zografopoulos
similarity 0.61
Abstract · IEEE North American Power Symposium (NAPS) 2026, 6 pages

Advanced Metering Infrastructure (AMI) plays an important role in modern power systems by providing near real-time consumption data for operational planning and load estimation. Despite this, AMI communication networks are vulnerable to certain cyberattack types, such as denial-of-service (DoS) and time delay attacks (TDAs), which may compromise data availability. This paper evaluates the impact of these attack types on AMI communication using a Mininet-based simulation environment that implements a communication model inspired by the Distributed Network Protocol 3 (DNP3) for communication among smart meters, data concentrators, and utility systems. Different cyberattack scenarios are analyzed, including communication delay, packet loss, combined degradation rate (D_rate), and concentrator failure, to evaluate their effects on network performance and data availability. The results indicate increased latency, higher communication unavailability rates, and reduced data reliability under attack conditions. In addition, the study correlates how communication degradation can result in potential uncertainties in energy demand estimation and provides estimates of the associated financial impacts on energy procurement, using electricity pricing data from the Independent System Operator-New England (ISO-NE). The experimental results reveal that a 500 ms delay increased the average RTT (Round-trip time) from 0.22 ms to 69.5 ms, while a 50% packet loss scenario resulted in 87 timeout events and a 5.31% communication degradation rate. Under a regional-scale deployment of 10,000 smart meters, this degradation could cause an estimated economic impact of $1,009/day under normal market conditions and up to $5,097/day during high-price events.

0.07

Composable, Knowledge-Driven Disservice Propagation for Complex Interdependent Services with a Flow-Allocation Module Validated Against Hydraulic Simulation

cs.CE ·2026-10-19 ·Cristian Curaba, Stefano Grimaz
publishedcode/data similarity 0.58
Abstract · Accepted at Complex Networks and Their Applications 2026 (COMPLEX NETWORKS 2026); supplementary material in ancillary files

Modeling cascading failure across interdependent critical infrastructure requires either a composable physical simulator per domain or a topological abstraction that discards quantity awareness. Simulators are costly, data-hungry, and require detailed calibration per domain; topological abstractions stay data-parsimonious while missing quantity-based behaviors that govern real dynamics. We present, instead, a knowledge-driven propagation architecture in which heterogeneous service dependencies are identified by categories: a general logical propagation resolves multi-dependency and redundancy structures purely from how nodes are categorized, while quantity-aware categories plug in dedicated mechanisms - here, a max-min fair-share flow module for water distribution. Both share one discrete functionality scale and a monotonic update algorithm guaranteeing convergence in finitely many rounds. We assess the flow module by comparing its results with those we get from preexisting pressure-driven simulation with WNTR (Water Network Tool for Resilience) on eight realistic networks across four failure families (clustered damage, capacity-targeted attack, source failure, tank loss). Under capacity-targeted attack and source failure a topological-reachability baseline misses 46% of the truly critical junctions, where the flow module misses 10% and 8% at an average critical-class precision of 0.73. Supplementary materials, code and results are available at: https://github.com/cascade-platform-org/CASCADE

0.46

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.56
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34

Dynamic Centrality Measures for Water Distribution Network Hydraulics

eess.SY math.OC ·2026-09-09 ·MirSaleh Bahavarnia, Salma M. Elsherif, Ahmad F. Taha
similarity 0.54
Abstract

Water distribution networks (WDNs) are susceptible to various failures, including but not limited to human errors, cyber-attacks, and network modifications, necessitating the vulnerability analysis of WDNs. Graph-theoretic centrality measures---as a main class of centrality measures---aim to rank the network components solely based on their influence (i.e., criticality) on the WDN topology in the case of input changes, while overlooking the WDN dynamics. To overcome such a limitation, this paper uses a control-theoretic centrality measure to identify the network's most and least influential pipes in WDNs, by simultaneously incorporating the dynamics and topology of the WDN. First, given a WDN modeled by nonlinear differential-algebraic equations (NDAEs) consisting of transient flow dynamics as differential equation (DE) and conservation of water mass as algebraic equation (AE) and considering the pipe flow rates as states of the state-space (SS) representation, we extract a linearized system modeled by linear ordinary differential equations (LODEs) around the equilibrium (i.e., steady) flow rate vector. Second, treating pipe flow rates as SS nodes (states), we introduce a node centrality-based measure, namely \textit{vulnerability vector (VV)}, to rank the network pipes based on their influence on the dynamics and topology of the WDN in the case of input changes. In particular, the network's most and least influential pipes can be identified through such a centrality-based approach. This enables water engineers to understand the WDN's vulnerability better and effectively prioritize the maintenance and operational efforts on the most influential pipes within the WDN.

0.25

GRID-MRI: Resilience Assessment of Power Systems under Coordinated Cyber-Physical Attacks

eess.SY cs.CR ·2026-11-12 ·Isaac Ortega Romero, Ioannis Zografopoulos
similarity 0.54
Abstract · IEEE PESGM 2027, 5 pages

The increasing penetration of inverter-based resources and growing cyber-physical interdependencies expose electrical power systems to disturbances that challenge conventional resilience assessments. Existing approaches often evaluate resilience dimensions independently, overlooking the non-additive effects of coordinated disruptions and the influence of exogenous stressors. To address this gap, this paper proposes a Grid Multidimensional Resilience Index (GRID-MRI) that integrates endogenous disruption severity, coordination effects, and climatic and economic-regulatory conditions. The framework quantifies physical, cyber, and operational degradation, identifies interaction effects through counterfactual (i.e., what-if), simulations of individual and coordinated attacks, and incorporates exogenous stressors as scenario-dependent scaling factors. Its application to a modified IEEE 39-bus system under three escalating cyber-physical attack scenarios, informed by the December 2025 Polish cyberattack incident, reveals that coordinated attacks induce system collapse despite stable individual and additive responses. The corresponding resilience losses are 3.72 and 4.09 times their additive estimates, while GRID-MRI increases from 0.062 to 1.188 and reaches 6.081 under additional exogenous stress. These findings demonstrate the limitations of additive assessments and establish a quantitative basis for distinguishing the dominant mechanisms of multidimensional resilience degradation.

0.36

Technical Report on Resilient and Secure Large-Scale Energy Internet Systems

eess.SY cs.CR ·2026-08-13 ·Ioannis Zografopoulos, Karen Largman, Isaac Ortega Romero, S M Zia Ur Rashid, Yexiang Chen +9 more
similarity 0.52
Abstract · Task Force on Resilient and Secure Large-Scale Energy Internet Systems, August 2026

This IEEE PES Task Force report examines the security and resilience of large-scale Energy Internet (EI) systems, in which electricity, information, and market layers are tightly coupled through pervasive digitalization. The report characterizes the EI cyber-physical threat landscape and surveys detection, assurance, and mitigation techniques, presents modeling, control, and decision-making frameworks that capture cyber-physical interdependencies, including storage integration, multi-dimensional resilience, and electricity price forecasting, examines adversarial risks and trustworthy deployment of artificial intelligence, and introduces graph-based, attack-resilient information routing. The report closes with recommendations for research, standardization, and regulatory efforts needed to realize a resilient and secure large-scale EI.

0.04

N-1 Security constrained Hosting Capacity Assessment for Ultra Large-scale Data Center with Workload Flexibility

eess.SY ·2026-11-18 ·Jiakai Wu, Pengyu Ren, Yifan Wang, Wei Sun
hot direction similarity 0.52
Abstract · conference

Transmission network security can substantially alter where large-scale data centers can connect and how much workload flexibility can unlock. This paper develops a hosting-capacity framework that couples computing demand, batch workload scheduling, and N-1 security constraints. A modified IEEE 118-bus case study reveals that two data center sites with identical hosting capacities under normal operation differ by 874.5 MW under the contingencies operation when workload flexibility is enabled. Six-hour batch deferral increases N-1 hosting capacity by up to 24.5\% relative to immediate execution. These gains arise from reducing demand at critical hours while accommodating deferred tasks within subsequent transmission limits and deadlines. At bus 92, a four-hour window captures 90.9\% of the six-hour capacity gain. The findings establish workload flexibility as a location-dependent connection resource whose capacity value requires joint assessment of contingency exposure and deadline constrainted workload recovery, beyond the power reduction available at a single critical hour.

0.31