CS Paper Radar

Economic Impact Assessment of Denial-of-Service and Time-Delay Attacks on Advanced Metering Infrastructure

Lais Oliveira Krohl, Saurav Basnet, Ioannis Zografopoulos

eess.SY cs.CR ·submitted 2026-08-10 09:14 UTC · v1

Abstract

Advanced Metering Infrastructure (AMI) plays an important role in modern power systems by providing near real-time consumption data for operational planning and load estimation. Despite this, AMI communication networks are vulnerable to certain cyberattack types, such as denial-of-service (DoS) and time delay attacks (TDAs), which may compromise data availability. This paper evaluates the impact of these attack types on AMI communication using a Mininet-based simulation environment that implements a communication model inspired by the Distributed Network Protocol 3 (DNP3) for communication among smart meters, data concentrators, and utility systems. Different cyberattack scenarios are analyzed, including communication delay, packet loss, combined degradation rate (D_rate), and concentrator failure, to evaluate their effects on network performance and data availability. The results indicate increased latency, higher communication unavailability rates, and reduced data reliability under attack conditions. In addition, the study correlates how communication degradation can result in potential uncertainties in energy demand estimation and provides estimates of the associated financial impacts on energy procurement, using electricity pricing data from the Independent System Operator-New England (ISO-NE). The experimental results reveal that a 500 ms delay increased the average RTT (Round-trip time) from 0.22 ms to 69.5 ms, while a 50% packet loss scenario resulted in 87 timeout events and a 5.31% communication degradation rate. Under a regional-scale deployment of 10,000 smart meters, this degradation could cause an estimated economic impact of $1,009/day under normal market conditions and up to $5,097/day during high-price events.

Comment
IEEE North American Power Symposium (NAPS) 2026, 6 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Data4Cyber: Labeled Cyber-Physical Datasets for Distribution-Grid Management Systems Under Representative OT Attacks

cs.CR ·2026-11-10 ·Ömer Sen, Lennart Bader, Marawan Emara, Martin Serror, Benedikt Schwalm +4 more
published similarity 0.64
Abstract

Cyberattacks against power systems increasingly exploit industrial communication and control dependencies arising from distributed energy resources (DER), remote management, and market-based incentives. Progress on intrusion detection is constrained by a lack of public datasets that align operational technology (OT) network telemetry with physical measurements and control context. Data4Cyber is a labeled cyber-physical dataset recorded in a laboratory distribution management system (DMS) for self-consumption optimization with photovoltaic generation, battery storage, controllable loads, and substation metering. It captures synchronized process measurements, controller context, price incentives, and packet captures (Modbus/TCP and MQTT) across one benign baseline and six attack scenarios spanning protocol-semantic Modbus manipulation, man-in-the-middle (MitM) false-data injection, and MQTT price manipulation. Its fixed 1 s time base, phase-resolved labels, and state-oriented representation support temporally blocked stateful-detector evaluation. Baseline results show that high recall alone is insufficient: several detectors achieve sensitivity through alarm saturation. Context-driven attacks require process-aware interpretation rather than single-channel thresholding.

0.63

Compound Environmental Operating Stress and Cyber-Induced Pump Disruption in Water Distribution Networks: Matched Hydraulic Impacts, Service Continuity, and Sustained Recovery

cs.CR eess.SY ·2026-10-26 ·Halil Dursunoglu, Fatma Dursunoglu
benchmark similarity 0.61
Abstract

Digitally controlled water distribution systems must maintain service during disruptions, yet restoring water delivery does not necessarily ensure hydraulic recovery. This study evaluates cyber-induced pump outages under hypothetical environmental operating stress using two EPANET benchmark networks (Net1 and Net3) simulated with the Water Network Tool for Resilience. The experimental design comprises 288 simulation records (240 distinct configurations), including 192 verified attack scenarios, with four- and twelve-hour outages, six hydraulic configurations, and four mitigation strategies. All attack scenarios satisfied pump-shutdown verification and pre-attack hydraulic-equivalence criteria. Twelve-hour outages produced an average of 404.96 m$^3$ of unmet demand in Net1, while Net3 maintained full modeled demand delivery despite pressure deviations. Sustained pressure recovery occurred in 103 of 192 scenarios, with 65 exhibiting subsequent relapse, whereas all scenarios satisfied the post-outage water-service recovery criterion. Combined mitigation eliminated unmet demand in evaluated Net1 scenarios, while outage shortening achieved the highest sustained-pressure-recovery count. These findings highlight network-dependent resilience and the distinction between service restoration and hydraulic recovery. Environmental stress scenarios represent sensitivity assumptions rather than empirically calibrated climate impacts.

0.37

Technical Report on Resilient and Secure Large-Scale Energy Internet Systems

eess.SY cs.CR ·2026-08-13 ·Ioannis Zografopoulos, Karen Largman, Isaac Ortega Romero, S M Zia Ur Rashid, Yexiang Chen +9 more
similarity 0.60
Abstract · Task Force on Resilient and Secure Large-Scale Energy Internet Systems, August 2026

This IEEE PES Task Force report examines the security and resilience of large-scale Energy Internet (EI) systems, in which electricity, information, and market layers are tightly coupled through pervasive digitalization. The report characterizes the EI cyber-physical threat landscape and surveys detection, assurance, and mitigation techniques, presents modeling, control, and decision-making frameworks that capture cyber-physical interdependencies, including storage integration, multi-dimensional resilience, and electricity price forecasting, examines adversarial risks and trustworthy deployment of artificial intelligence, and introduces graph-based, attack-resilient information routing. The report closes with recommendations for research, standardization, and regulatory efforts needed to realize a resilient and secure large-scale EI.

0.04

Robustness of Local Energy Markets to Cyberattacks: Case Study of False Data Injection

cs.CR ·2026-09-29 ·Mehran Moradi, Reza Zamani, Phil Aupke, Andreas Theocharis, Andreas Kassler
similarity 0.59
Abstract

Market clearing in community-based local energy markets relies on power demand and PV forecasts, making it vulnerable to coordinated false data injection (FDI) attacks. This paper proposes a bilevel optimization framework to identify worst-case bus-level FDI against interconnected multi-community electricity markets within a distribution network. The upper level attacker maximizes physical impact, measured by cumulative voltage deviation, while accounting for detectability. The lower level re-clears the interconnected multi-community markets subject to operational and network constraints. The bilevel model is reformulated as a single-level mixed-integer program through Karush-Kuhn-Tucker conditions and solved using the epsilon constraint method to characterize the trade-off between physical impact and detectability. Case studies on the IEEE 33-bus system with three communities show that even bounded, system-level zero-sum attacks can reshape local trading, reduce voltage security margins, and produce asymmetric community-level market outcomes. The results further show that vulnerability depends strongly on the spatiotemporal placement of falsified data rather than on uniform spreading across buses and time periods.

0.26

Quantifying EnergyNet performance: a simulation-based framework for decentralized energy networks

eess.SY ·2026-09-29 ·Max Collins, Jonas Birgersson, Marc A. Weiss, Jimmy Chen, Mark Z. Jacobson +8 more
similarity 0.58
Abstract

Power transmission and distribution infrastructure connects generation with consumers. Extreme weather, infrastructure failures, and geopolitical conflicts increasingly disrupt these connections, leaving large groups without electricity until service is restored. Local generation, storage, and controllable loads pose challenges but also enable new ways to organize energy systems. EnergyNet is a decentralized architecture of interconnected power electronic Energy Routers. Each coordinates local loads, generation, storage, and grid connections. Bidirectional Energy Links enable exchange between routers, while the Energy Protocol communicates needs and availability to coordinate transfers. EnergyNet can operate with or without the public grid. This paper develops a quantitative framework for modeling and evaluating EnergyNet. It represents topology, prioritized loads, generation, storage, grid connections, links, and component limits. Receding-horizon optimization calculates energy allocation and exchange, supporting also disturbance and reliability analysis. A three-router case illustrates energy sharing and islanded operation. The framework then models a Stanford University campus microgrid and an off-grid microgrid in Half Moon Bay. Under low-solar conditions, electric bus visits support the off-grid microgrid while preserving transport service. Finally, the paper models an EnergyNet under construction in Lund, Sweden, comprising ten buildings and 278 apartments. Full service is maintained in summer and winter and after the loss of one grid interface or Energy Link. Losing two links partitions the network; service in the island depends on local resources and repair time. Reliability screening identifies partitioning as rare but credible. Monte Carlo analysis shows full critical service in sampled summer conditions and median continuous critical service of approximately 92% in winter.

0.41

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.56
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

GRID-MRI: Resilience Assessment of Power Systems under Coordinated Cyber-Physical Attacks

eess.SY cs.CR ·2026-11-12 ·Isaac Ortega Romero, Ioannis Zografopoulos
similarity 0.56
Abstract · IEEE PESGM 2027, 5 pages

The increasing penetration of inverter-based resources and growing cyber-physical interdependencies expose electrical power systems to disturbances that challenge conventional resilience assessments. Existing approaches often evaluate resilience dimensions independently, overlooking the non-additive effects of coordinated disruptions and the influence of exogenous stressors. To address this gap, this paper proposes a Grid Multidimensional Resilience Index (GRID-MRI) that integrates endogenous disruption severity, coordination effects, and climatic and economic-regulatory conditions. The framework quantifies physical, cyber, and operational degradation, identifies interaction effects through counterfactual (i.e., what-if), simulations of individual and coordinated attacks, and incorporates exogenous stressors as scenario-dependent scaling factors. Its application to a modified IEEE 39-bus system under three escalating cyber-physical attack scenarios, informed by the December 2025 Polish cyberattack incident, reveals that coordinated attacks induce system collapse despite stable individual and additive responses. The corresponding resilience losses are 3.72 and 4.09 times their additive estimates, while GRID-MRI increases from 0.062 to 1.188 and reaches 6.081 under additional exogenous stress. These findings demonstrate the limitations of additive assessments and establish a quantitative basis for distinguishing the dominant mechanisms of multidimensional resilience degradation.

0.36

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.54
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41