CS Paper Radar

Knowledge distillation across teacher architectures for compact diabetic retinopathy grading

Mossa Manisa, Habiba Jahan Priya, A. K. M. Fakhrul Hossain

cs.LG cs.CV ·submitted 2026-10-25 10:31 UTC · v1
unusual

Abstract

Diabetic retinopathy grading from retinal fundus photographs is important but difficult to deploy on resource-constrained hardware. We conducted a controlled study of offline response-based knowledge distillation for five-class diabetic retinopathy grading on APTOS 2019, comparing ResNet-50, MobileNetV3-Large, and Swin Transformer-Tiny (Swin-T) teachers distilled into a MobileNetV3-Small student. A 3 x 4 x 2 grid of teacher, temperature, and hard-label weight was screened at one seed, while six configurations and the no-distillation baseline were evaluated across three seeds. The highest observed single-seed quadratic weighted kappa was 0.9093 (macro-F1 0.6851) for Swin-T at temperature 4 and hard-label weight 0.7; the corresponding three-seed mean was 0.9024, compared with 0.8804 for the baseline. The student used 1.52 M parameters and 5.94 MB, representing an 18.07x parameter reduction relative to Swin-T. Temperature and hard-label weight effects were teacher- and configuration-dependent, while small performance differences were sensitive to random seed. Knowledge distillation produced a compact student with competitive performance under the evaluated protocol, but independent external validation remains necessary.

Comment
17 pages, 3 figures, 18 tables. Submitted to PLOS ONE

Closest papers

Nearest neighbours by meaning across the whole index.

CalibCause: A Quality-Gated, Interpretable and Calibrated Deep Learning Framework for Diabetic Retinopathy Grading

eess.IV cs.LG ·2026-10-28 ·Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
similarity 0.66
Abstract · 15 pages, 8 figures, 6 tables

Most deep learning systems for diabetic retinopathy (DR) grading are evaluated on a single data source, with limited evidence of cross-site generalisation, uncertainty calibration, and interpretability. We propose CalibCause, a quality-gated mixture-of-experts framework that combines per-expert visual explanations, label-free image-quality conditioning, knowledge distillation, and calibrated confidence with deferral. We evaluated the framework using 51,310 fundus images from EyePACS, DDR, and APTOS 2019, with IDRiD and DeepDRiD for external testing. Evaluation included pooled testing, leave-one-environment-out experiments, paired bootstrap confidence intervals, and local grade-threshold adaptation. On the pooled test split, the label-free distilled student achieved quadratic weighted kappa (QWK) of 0.863 and accuracy of 0.865 with 27.8 million parameters, 52% fewer than its teacher. Across held-out environments, the label-free model achieved mean QWK of 0.741 compared with 0.743 for a plain ConvNeXt-Tiny baseline, while adversarial invariance did not improve cross-site grading accuracy. Refitting grade thresholds using 200 labelled images increased held-out EyePACS QWK from 0.533 to 0.621 for the label-free model. After vector scaling, expected calibration error ranged from 0.025 to 0.036 across CalibCause variants, and deferring the least confident 20% of images increased student accuracy from 0.865 to 0.923 on the remaining images. These findings demonstrate that quality-aware grading, interpretable expert routing, model compression, and calibrated deferral can be integrated without sacrificing cross-site performance relative to a plain baseline, although reliable deployment still requires local validation and adaptation.

0.22

Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images

cs.CV cs.AI ·2026-11-14 ·Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
similarity 0.59
Abstract · 12 pages, 6 figures, 9 tables. Truong Thinh Nguyen and Hai Phong Nguyen contributed equally. Corresponding author: Truong Thinh Nguyen

Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.

0.13

Multi-Channel Feature Fusion and Monte Carlo Dropout for Uncertainty-Aware Diabetic Retinopathy Grading

eess.IV cs.CVeess.SP ·2026-08-15 ·Saksham Kumar
similarity 0.56
Abstract

Automated five-stage diabetic retinopathy (DR) grading requires more than high accuracy alone. Medical-grade deployment calls for lesion-aware preprocessing, ordinal predictions, calibrated uncertainty, and explainability to support reliable diagnostic systems. We present a unified pipeline that addresses these requirements using a Ben-Graham-green-channel CLAHE feature representation, an EfficientNetV2-L ordinal regressor, and Monte Carlo dropout for uncertainty-driven referral. Grad-CAM provides visual explanations aligned with clinically relevant lesions. The proposed method achieves a QWK of 91.31% on the APTOS-2019 official test split, placing it within the near-perfect agreement band (>80%). At a 20% referral rate, 293 of 366 images are automatically graded with a QWK of 90.40%. More complex cases are referred for specialist assessment, demonstrating a practical trade-off among grading quality, automation, and patient safety in robust, reliable, and deployment-ready medical diagnostic systems.

0.04

Representational Difference Distillation

cs.LG cs.CV ·2026-10-11 ·Abdulkarim Mugisha, Divin Irakiza
similarity 0.56
Abstract · 9 pages, 7 figures, 1 table

Knowledge distillation transfers representational knowledge from a large teacher network to a compact student. Existing relational and contrastive distillation methods treat all samples uniformly, spending equal gradient on well-matched and poorly-matched regions of the representation space alike. We propose Representational Difference Distillation (RDD), which diagnoses where teacher and student representations structurally disagree and concentrates the distillation signal on those regions. RDD uses two asymmetric affinity matrices that capture opposing directions of misalignment: one identifies samples the student incorrectly considers similar, the other identifies teacher relationships the student has yet to learn. These affinities determine which sample pairs the distillation loss aligns and how strongly it corrects each misaligned sample. On CIFAR-100 with resnet32x4 to resnet8x4, RDD reaches 75.58% test accuracy in our runs, on par with CRD (75.45%) and above KD and RKD. We additionally explore curriculum-based and sampling-based variants, finding that weighting the loss is more effective than filtering the data.

0.18

Promise and Limits of Cross-Architecture Knowledge Distillation for Lightweight Medical Vision Transformers (LiteMed-ViT)

cs.CV ·2026-10-24 ·Shuaibu Shehu, Elijah M. Flomo, Mohammad Safiya, Anurodh Kumar, Subodh Kumar
published similarity 0.55
Abstract · 6 pages, including references. Accepted at the International Conference on Intelligent Computing and Secure Communication Systems (ICICSCS 2…

Running deep models for medical image analysis at the point of care is challenging with standard architectures: convolutional neural networks (CNNs) are often too heavy for edge devices, while Vision Transformers (ViTs) require massive training datasets to compensate for missing inductive biases. This study investigates how far the dual-token distillation used to train data-efficient ViTs can be pushed when applied across architectures, from a CNN-based teacher into a lightweight ViT student. LiteMed-ViT is introduced as a dual-token ViT featuring a convolutional stem and a class-balanced distillation objective; at 0.234M parameters, LiteMed-ViT carries 47.8x fewer parameters than its ResNet18 teacher at a memory footprint of just 0.89 MB. Evaluated against three compact CNN baselines on three MedMNIST subsets of varying modality and class balance, LiteMed-ViT attains higher accuracy than all three baselines on BloodMNIST (95.05%) and two on PathMNIST (89.15%). Under MedMNIST-C corruptions, it is at least as robust as every compact CNN across all subsets, outperforming them on BloodMNIST and PathMNIST without declining in relative standing as severity increases. Particular attention is devoted to identifying the exact conditions where performance plateaus. On DermaMNIST, LiteMed-ViT's balanced accuracy remains up to 1.9 points below the strongest compact CNNs and does not benefit from higher input resolutions up to 224 pixels, where ResNet18 gains 12.6 points. Stronger teachers do not yield a more accurate student, and overconfident ones lower its DermaMNIST balanced accuracy unless calibrated.

0.27

Transferring Visual Explanations: How Cross-Architecture Knowledge Distillation Affects Model Interpretability

cs.CV ·2026-09-20 ·Aleks Czufarow, Ihor Babin
published similarity 0.55
Abstract · 21 pages, 4 figures, 2 tables. Submitted to AJOSR

Deploying efficient neural networks is essential in resource-constrained environments, yet compact models often sacrifice interpretability - a critical in safety-critical domains such as autonomous driving and medicine. This study investigates whether Knowledge Distillation transfers the spatial feature attribution of a large teacher network to a compact student. To assess the influence of the KD scheme on interpretability, we distill a ResNet-152 teacher into a ResNet-34 student on ImageNet-1K across five configurations by systematically varying the distillation temperature and soft-label loss weight. Models are evaluated on top-1 accuracy, along with two interpretability metrics: Relevance Mass Accuracy and Relevance Rank Accuracy. These metrics are computed via Grad-CAM heatmaps benchmarked against ground-truth object masks. Our results show that top-1 accuracy ranges from 71.6% to 74.0%. For Grad-CAM, RMA ranges from 7.7% to 9.7% and RRA from 7.3% to 10.1%; for Guided Grad-CAM, RMA ranges from 16.1% to 18.6% and RRA from 15.9% to 21.5%. Interpretability proves far more sensitive to the soft-label weight than to the temperature: keeping the student anchored to hard labels preserves both accuracy and coarse localization, whereas weighting the teacher heavily degrades both. Fine-grained attribution, however, fell below the undistilled baseline in every configuration tested, indicating that logit distillation transmits where a model attends more readily than the pixel-level structure of that attention. We evaluate 12 cross-architecture combinations of convolutional and transformer-based models, revealing that the inheritance of fine-grained spatial reasoning is fundamentally bottlenecked by the student's intrinsic structural biases. To our knowledge, this is the first application of this interpretability-aware evaluation framework - previously used for neural network pruning - to KD.

0.39

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

cs.CV ·2026-10-13 ·Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam
code/datahot direction similarity 0.54
Abstract · 8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predic…

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

0.45

Scaling Multi-Teacher Distillation for Digital Pathology

cs.CV ·2026-10-08 ·Sofiène Boutaj, Pierre Marza, Varun Belagali, Dimitris Samaras, Maria Vakalopoulou +1 more
top venuecode/data similarity 0.52
Abstract · Accepted at NeurIPS 2026. Project page: https://sofiene-boutaj.github.io/omni-projectpage/

Multi-teacher distillation allows transferring knowledge from multiple "teacher" networks to a single "student" network. This method is promising in fields such as digital pathology, where many powerful foundation models were proposed recently. However, as we show in this paper, the standard multi-teacher distillation approach reacts poorly to an increase in the number of teachers used to train a student encoder. We demonstrate that learning teacher-specific representations is a key to scaling in MTD. Importantly, different design choices, such as learnable teacher tokens, a tailored attention scheme, additional mixture-of-experts layers and a contrastive loss, are proposed to better learn such teacher-specific representations. We show that our method better scales with respect to the number of considered teachers, allowing us to train compact student encoders, up to 10x more efficient than larger teacher foundation models, while matching their performance and even outperforming them on a large set of tile-level and slide-level tasks. We conduct a thorough empirical validation, evaluating more than 10 foundation models on 39 tasks spanning tile and slide levels. As a result, we release a new collection of strong and efficient foundation models, named OMNI, trained from the knowledge of 10 state-of-the-art foundation models. We finally conduct an analysis of the learned teacher-specific representations, highlighting their complementarity and explaining why they can be easily aggregated at downstream time.

0.39