CS Paper Radar

PRISM: Pathology Reliability In Scarce-label Medicine. A Tile-level Benchmark of Pathology Foundation Models

Alicem Koyun

cs.LG cs.CV ·submitted 2026-10-27 02:20 UTC · v1
publishedbenchmarkcode/data

Abstract

Pathology foundation models are typically benchmarked on classification performance at full label availability and on in-distribution test sets, while calibration, behavior at low label budgets, and robustness under cross-institutional shift are seldom evaluated jointly. We introduce PRISM, a tile-level benchmark that measures the reliability of pathology foundation models along four axes: model choice, label fraction, calibration, and out-of-distribution transfer. PRISM evaluates eight foundation models (CLIP, PLIP, CONCH, UNI, Virchow2, GigaPath, H-Optimus-0, Midnight) on six tile-level datasets at six label fractions (1% to 100%) with three seeds (864 linear probe runs), extended with a five-hospital Camelyon17 study of 20 directed transfer pairs. Four phenomena emerge. (i) Under full supervision, AUROC rank predicts post-temperature calibration rank consistently across datasets (Spearman rho = 0.52, I^2 = 0%), whereas at 1% labels the relationship becomes dataset-specific (rho = -0.24, I^2 = 67%). (ii) On harder datasets the linear probe collapses to a single predicted class below a dataset-specific label fraction. (iii) Whether additional source-domain labels help or harm target calibration tracks how well the probe transfers: below a transfer AUROC of roughly 0.85, more labels worsen target ECE in 86-88% of combinations. (iv) Temperature scaling fails to reduce ECE in 49 of 288 cells, miscalibration is predominantly under-confidence, and a source-fitted temperature is harmful under failing transfer. PRISM is released as a pip-installable package with reference results for all 288 cells. Code and data: https://github.com/alicemkyn/prism-benchmark

Comment
30 pages (9 main), 21 figures. Accepted at the Third Workshop on GenAI for Health (GenAI4Health) at NeurIPS 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

cs.CV ·2026-08-26 ·Juan Iñaki Larrea, Lucas Mansilla, Enzo Ferrante
published similarity 0.64
Abstract · Accepted at MIRASOL Workshop, MICCAI 2026. 10 pages, 3 figures

Foundation models are increasingly deployed for medical image analysis. However, under the inter-institutional distribution shift typical of deployment, their performance varies widely and cannot be known without target-domain labels, which are rarely available. This leaves a practical question unresolved: given several candidate foundational models and labeled-data from a source domain, which one to deploy in an unlabeled target domain? We propose a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations. SUDO partitions the unlabeled target data by predicted probability and, for each region, measures a pseudo-label discrepancy reflecting class contamination; aggregated across regions, this yields a score (AURCC) requiring neither target annotation nor fine-tuning. We show that AURCC can be used to rank a variety of vision-language models (BioMedCLIP, CXR-CLIP, CheXzero, MedCLIP, MedImageInsight, CLIP) on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes. The AURCC ranking recovers the ground-truth ranking with Spearman rho up to 0.943 (p<0.05). Against the natural baseline of ranking by held-out source accuracy, AURCC is competitive when the labeled source is large and yields a more accurate ranking once it is small; the regime of interest in resource-constrained settings.

0.19

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

cs.CV cs.LG ·2026-11-04 ·Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti
publishedbenchmarkcode/data similarity 0.64
Abstract · Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome…

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

0.46

RadFusion: Towards Threshold-Controllable Radiology Report Generation

cs.AI cs.CLcs.CV ·2026-08-11 ·Ying Jin, Noel C. F. Codella, John Corring, Mu Wei, Dinei Florencio +1 more
similarity 0.60
Abstract

Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions. A single fixed report can neither adapt to these scenarios nor support the ROC-based validation widely expected for regulatory clearance. We introduce RadFusion, a framework that equips report generation with threshold controllability. Our method fuses a multi-label classifier, which provides per-disease confidence scores, with a VQA-based report generator, which describes medical findings in detail; an LLM then rewrites the report so that its stated diagnoses follow the classifier's decisions at the selected threshold while staying grounded in the generator's descriptions. On MIMIC-CXR, the performance of RadFusion conforms to the classifier's ROC curve: sweeping the threshold and mapping the reports back to class labels reproduces the classifier's validated ROC performance. This conformance makes generated reports quantitatively evaluable through ROC analysis, strengthening the case for regulatory clearance, and enables operating-point selection that matches report behavior to clinical context. Moreover, combining the two model types improves diagnostic accuracy over uncontrolled generation: sensitivity increases by 6.9% at matched specificity, and specificity by 20.7% at matched sensitivity. These results show that RadFusion makes report generation clinically adaptable, quantitatively verifiable, and diagnostically more reliable.

0.04

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions

eess.IV ·2026-10-15 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
similarity 0.60
Abstract · 8 pages, 4 figures

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

0.47

OpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation

cs.CV ·2026-11-03 ·Qizhen Lan, Yu-Chun Hsu, Yuxiang Wei, Lijing Zhu, Zenan Sun +3 more
top venuecode/data similarity 0.60
Abstract · Accepted at NeurIPS 2026, Evaluations and Datasets Track. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain; code: https://github…

Automatic tools can now generate whole-brain MRI parcellations at cohort scale, but generated-label releases often provide little evidence about which cases are reliable enough to reuse. We introduce OpenBrain, a confidence-aware release of 35,838 provenance-verified OpenNeuro T1w cases from 607 source datasets. OpenBrain is organized as an auditable case-record release rather than a directory of standalone segmentation files: each record links a primary parcellation, two committee parcellations, source/license provenance, raw QC-7 measurements, percentile risks, a combined risk score R, and a confidence tier. QC-7 is a reference-free reliability panel over label geometry, image-label consistency, and committee disagreement, so users can filter, weight, audit, or re-threshold generated labels without rerunning inference. We evaluate this released evidence under a frozen protocol. Across external cohorts, lower QC-7 risk corresponds to higher generated-label quality; in fixed-budget training, lower-risk selections improve paired macro Dice over random selection by +3.2 to +3.7 percentage points. OpenBrain also exposes raw axes, committee outputs, provenance, and datasheet documentation, so confidence claims remain inspectable after download. It does not turn generated labels into manual annotations or clinical-grade segmentations. Its contribution is a large open generated-parcellation substrate, a reusable case-level risk-evidence layer, and an external validation protocol for release-time QC. Dataset: https://huggingface.co/datasets/lanqz7766/OpenBrain. Code: https://github.com/lanqz7766/openbrain.

0.44

How Far from Clinical Deployment? Evaluating the Complete Unsupervised Domain Adaptation Pipeline in Medical Imaging

cs.CV cs.AI ·2026-08-12 ·Yiheng Xiong, Luisa Gallée, Daniel Santak Wolf, Heiko Hillenhagen, Michael Götz
publishedcode/data similarity 0.59
Abstract · Accepted to WACV 2027

Deploying unsupervised domain adaptation (UDA) in clinical practice requires choosing which algorithm to use and which of its trained models to ship. However, the deployment (target) domain is unlabeled, so models cannot be evaluated directly on it, leaving it unclear which to select. We address this by evaluating the complete UDA pipeline, considering both adaptation and label-free selection together. Our study covers eleven clinically relevant cross-domain scenarios from nine medical imaging datasets, with ten UDA algorithms and 13 label-free selection methods (validators), evaluating over 80,000 trained models in total. By this, we find that a capable adapted model usually exists, but identifying it without target labels is difficult: the validator-selected models leave a large and structural target performance gap to the best available one, with no evaluated validator consistently reliable. Towards closing it, we explore two strategies, ensembling and a small target-labeling budget; both narrow this gap but do not close it entirely. Overall, deployable UDA depends on the complete pipeline; addressing the less explored selection step could bring much of current UDA closer to clinical use. Our code is open sourced at \href{https://xiongyiheng.github.io/complete-uda-pipeline-site/}{Project Page}.

0.80

Detecting Unreliable Classifications from Quantized Models

cs.CV ·2026-10-13 ·Ananya Kotla, Jorge T. Gomez
hot direction similarity 0.59
Abstract · 1 figure, 5 tables

Post-training INT8 quantization is typically validated by checking accuracy retention, which requires ground-truth labels often unavailable in low-resource clinical settings. We show a label-free alternative: comparing a model's own output before and after quantization. We compute cosine similarity between the FP32 and INT8 models' output probability vectors for each prediction, which requires only a single forward pass. This output-agreement similarity separates lower-accuracy predictions across four evaluated architectures (ResNet-50, VGG-16-BN, Wide ResNet-50, and ViT-B/16) under fixed-percentile splits, outperforming a confidence-only baseline for all four. These results show that quantized models can be compared to their baselines to assess their drift and determine whether they are well suited for clinical deployment.

0.31

Label-Free Coreset Selection with Foundation Models for Efficient Annotation in Computational Pathology

cs.CV ·2026-10-05 ·Tuo Yin, Jennifer Dhont
code/data similarity 0.59
Abstract · 32 pages, 7 figures

Computational pathology has the potential to improve clinical outcomes through a demonstrated increase in diagnostic and prognostic accuracy. However, the development and validation of deep learning algorithms still require annotated data, a costly procedure involving expert pathologists who already face critical workforce shortages. Existing coreset selection methods to optimize annotation efforts currently all rely on hyperparameters tuned on natural-image benchmarks that do not transfer to histopathology and are cumbersome to use in clinical practice. In this study, we present GCcore, a novel label-free coreset selection method that embeds every image of a dataset with any pathology foundation model and greedily selects the samples that collectively maximize the global coverage of the embedding space. The proposed method provides a lower-bound guarantee on the global coverage of the returned coreset for any coreset size, while being completely hyperparameter-free and deterministic. We demonstrate GCcore's superior performance over 14 baselines including state-of-the-art methods across 10 tasks and datasets spanning whole slide image classification, tile classification, and tissue segmentation, where it ranks first on six and within the top three on nine, while also demonstrating how existing methods can shift by up to five rank positions depending on their hyperparameter settings. Code is publicly available at https://github.com/OncoAI-ULBHUB/GCcore.

0.23