Abstract

Care for type 2 diabetes increasingly draws on continuous glucose monitors, wearable devices, home sensors, clinical records and retinal images, yet few open platforms have been shown to hold all of these for the same person. We asked three questions of DHIS2, the open-source health information system that ministries of health in about 80 countries run nationally: whether an unmodified Tracker program can represent these modalities together (RQ1), which design choices its row-per-event data model forces for dense sensor streams (RQ2), and what a bulk loader must do to load such data correctly (RQ3). We designed a registry of 27 program stages and 445 data elements, loaded the AI-READI dataset of 2,280 participants into it, and verified the result field by field against the source files. The program held every loaded modality in 8.09 million events. Dense streams were stored as hourly summaries aligned across modalities; electrocardiograms, diagnoses and 118,480 retinal images were stored as one event per record. The event model ruled out storing raw readings, and hourly summaries reduced the wearable and glucose volume about 26-fold. An audit of the loader found defects that shared one pattern: a failure that looked like success. We state five lessons for DHIS2 Tracker clients that address this pattern. Verification of all 64.9 million stored values found four defects, all missing, duplicated or artifactual records rather than wrong values, and none after their repair; an independent recomputation of the glucose summaries agreed on all 464,210 values compared. The paper offers implementation guidance for DHIS2 implementers and for users of AI-READI; it does not evaluate clinical use. Analytics at this scale, use by clinicians and live device feeds remain to be shown.

Closest papers

Nearest neighbours by meaning across the whole index.

An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads

cs.DC ·2026-08-11 ·Elias Grünewald, Daniil Cherepko, Linus Gustafsson, Jakob Möhler, Oskar Rabe +5 more
code/data similarity 0.55
Abstract · Wearables, Cloud Native, Stream processing, FHIR, Clinical Decision Support

Continuous physiological monitoring using consumer-grade wearables offers a transformative opportunity for clinical care and research, yet integration remains hindered by device heterogeneity, proprietary data formats, and strict regulatory requirements. We present an event-driven, cloud-native system designed to ingest, normalize, and analyze high-frequency vital signs from wearables at scale and without vendor lock-in. The system design proposes a multi-layered microservice architecture using cluster orchestration. Data acquisition is handled via a cross-platform mobile application that leverages native health frameworks, ensuring compatibility across fragmented device ecosystems. To address interoperability, we implement an event-driven transformation pipeline using stream processing engines and specialized services to map raw measurements to the FHIR standard for medical interoperability. Our novel dependency-aware FHIR minimization scheme reduces storage overhead while maintaining lossless resource reconstruction. Furthermore, the platform integrates a modular data analytics and machine learning layer based on a medallion lakehouse architecture, supporting the full machine learning lifecycle from real-time stream processing to model serving. Performance evaluation demonstrates that the ingestion pipeline sustains 50 full ingestion requests per second with median response times under 8 ms, satisfying the low-latency requirements for real-time patient monitoring. Our open-source implementation adheres to regulatory compliance standards through role-based access control and secure service-to-service communication, providing a robust foundation for deploying wearable-based monitoring in institutional healthcare settings for clinical decision support and research workloads.

0.20

GlucoAgent: Personalized Glucose Forecasting from Multimodal Personal Context

cs.AI ·2026-11-03 ·Xingzhi Sun, Hyo Jin Kim, Zhiyuan Wang, Hao Chen
published similarity 0.55
Abstract

Continuous glucose monitors, smartwatches, meal logs, and health profiles form a rich multimodal personal context that can significantly enhance glucose forecasting. However, existing methods struggle to effectively utilize these signals to improve glucose prediction because the relevance of different modalities varies drastically across individuals and time. We present GlucoAgent, an LLM-based agentic system that addresses this challenge through dynamic, case-by-case analysis at inference time. For each forecast, GlucoAgent writes and runs code over an individual's multimodal context and returns predictions with a reason and supporting evidence. The generated programs are highly diverse, ranging from retrieving similar past meals to fitting and back-testing physiological and statistical models. On CGMacros, a multimodal glucose dataset, GlucoAgent outperforms time series foundation models on every forecasting horizon, achieving an average RMSE of 22.5 mg/dL compared to 23.5 mg/dL of Chronos-2, the leading multimodal time series foundation model. Furthermore, GlucoAgent is highly effective at leveraging multimodal data. The addition of multimodal data reduces its average RMSE by 1.4 mg/dL (24.0 mg/dL to 22.5 mg/dL), compared to a marginal 0.3 mg/dL (23.8 mg/dL to 23.5 mg/dL) improvement for Chronos-2. This advantage is most pronounced in challenging post-meal windows, where GlucoAgent uses multimodal context to reduce 60-minute forecast RMSE by 4.6 mg/dL (31.0 mg/dL to 26.5 mg/dL), far exceeding the 0.8 mg/dL (31.9 mg/dL to 31.1 mg/dL) reduction achieved by Chronos-2.

0.33

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.54
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.54
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

Diffusion-Based Synthetic Data Pretraining for Enhancing Activity Recognition

cs.LG cs.AI ·2026-10-01 ·E. Riveros, D. Vega-Oliveros, A. Soriano-Vargas, A. Rocha
similarity 0.54
Abstract · 6 pages, 3 figures, 1 table

Human activity recognition (HAR) is increasingly important for healthcare, well-being, and daily monitoring ap- plications, for which detecting alimentary activities such as eating and drinking can provide actionable insight into dietary habits and chronic disease management. HAR systems, however, often underperform on subtle and underrepresented classes, limiting their utility in real-world dietary monitoring. This work builds upon CABiGRU, a convolutional architecture with Bidirectional GRU layers, multi-head attention, and residual connections, designed to capture discriminative temporal patterns from smart- watch accelerometer, gyroscope, and magnetometer data. To improve CaBiGRU's generalization and reduce underfitting in the minority class, we leverage synthetic sensor data windows using a diffusion model and adopt a two-stage training strategy: pre-training CABiGRU on synthetic data, followed by fine-tuning on the real-world data. On the DEO (drinking/eating/other) dataset, the proposed pipeline achieves a balanced accuracy of 90.6%, improving over a strong supervised baseline and showing the benefits of diffusion-based synthetic pre-training for recognizing alimentary activities and representing a step forward dealing with unbalanced classes. These results suggest that combining diffusion-generated data with targeted fine-tuning enhances robust recognition of dietary behaviors, supporting more reliable deployment in healthcare and nutrition-monitoring settings.

0.18

WearableQA: A Benchmark for Health Reasoning over Real-World Wearable Data

cs.CL ·2026-09-04 ·Ji Soo Lee, Xilun Chen, Pierce Chuang, Ashish Shenoy, Jason Wei +3 more
benchmarkcode/data similarity 0.53
Abstract

Recent advances in wearable sensing enable continuous monitoring of physiological and behavioral signals, yet existing benchmarks rarely evaluate whether AI systems can reason over a real user's longitudinal wearable record. We introduce WearableQA, a benchmark comprising 4,084 10-option multiple-choice questions constructed from the wearable time series, blood biomarkers, and demographics of 200 real users, each with up to 500 days of daily measurements. WearableQA preserves authentic wearable distributions that include device noise and inter-individual variability. To evaluate distinct reasoning capabilities, we introduce 16 question types organized along two complementary axes: data versus health reasoning, which distinguishes computation over longitudinal measurements from physiological interpretation; and single- versus cross-signal reasoning, which separates reasoning about individual signals from the integration of multiple signals. To construct reliable questions at scale, we adopt a dual-grounding framework that combines literature-grounded physiological findings with statistically validated population-grounded physiological patterns. This enables the capture of meaningful relationships observed in real-world wearable data. Evaluation of 14 proprietary and open-source LLMs demonstrates that WearableQA effectively differentiates model capabilities, with performance ranging from 19.6% to 72.9% against a 10% chance baseline. Moreover, WearableQA remains far from solved: most models achieve accuracies below 60%. Overall, WearableQA provides a realistic and diagnostic benchmark for evaluating LLM reasoning over real-world wearable data.

0.18

Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose

cs.LG cs.AI ·2026-11-11 ·Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko +1 more
publishedbenchmarkdatasetcommunity pick similarity 0.53
Abstract · IEEE ICDM 2026 - Best Paper Runner-Up (Applied Track)

Electronic nose (eNose) technology offers a portable, non-invasive route for disease screening via exhaled breath analysis. However, progress in the field is hindered by the lack of systematic benchmarks that compare machine learning methods under realistic conditions, particularly sensor drift, a known but rarely quantified failure mode. Most existing studies rely on small, private datasets with inconsistent protocols, rendering results non-comparable and slowing progress. We introduce Breath-Dx, the first comprehensive benchmark of time series classification methods for breath-based disease screening. Our work leverages the Scent of Health (S-OH) dataset, the largest public clinical eNose collection to date, comprising 1,234 patients across nine diagnostic groups, each providing a 17-channel multivariate time series with explicit temporal train/test splits that account for sensor drift. We systematically evaluate 10 methods spanning four families: feature-based tabular learners, convolution-based models, graph-based, and time series architectures. All methods degrade significantly under temporal validation (0.05-0.12 AUC drop compared to random cross-validation), confirming that drift embeds a strong temporal signal. Under this realistic evaluation, the best methods achieve ROC AUC of 0.74-0.76 for some lung conditions, though others remain near chance. Recurrent architectures show the most consistent performance across diseases, while specialized time series methods achieve the highest peak results. Demographic confounders matter: breath signals provide independent diagnostic value for some conditions but add little beyond age for others. We release the S-OH dataset, all temporal splits, evaluation protocols, and code to enable reproducible research and accelerate progress in clinical breathomics.

0.47

Operation-aware Multimodal Clinical Decision Support System for ICU Discharge Risk Assessment

cs.LG ·2026-11-09 ·Guoqing Zhang, Rafik Hadfi, Takayuki Ito
benchmarkcode/data similarity 0.53
Abstract · 14 pages, 2 figures. Code available at https://github.com/KuoChing-cmd/ClinicalNoteAgent/

Unplanned 30-day intensive care unit (ICU) readmission is a critical benchmark for evaluating healthcare quality. Most predictive models assume readmission risk depends solely on a patient's individual pathophysiological state, ignoring hospital operational context and resource capacity. In practice, discharge decisions are dynamic trade-offs between patient stability and bed turnover pressures. To address this gap, we develop an Operation-aware Multimodal Clinical Decision Support System (CDSS) for ICU discharge risk assessment. The system combines multi-agent collaborative extraction with self-evolving retrieval-augmented generation (RAG) to eliminate template noise from progress notes, while constructing departmental workload indicators alongside admission flow features, continuous vital signs, and sparse medical codes (ICD/DRG). Addressing severe class imbalance (about 10.5% readmissions) and alarm fatigue, we implement data normalization, class reweighting, and decision-threshold calibration. In 20 independent runs across 20,000 ICU stays from MIMIC-III, empirical findings demonstrate that: vital signs alone have limited predictive capacity under real-world class imbalance (PR-AUC of 0.1387 +/- 0.0086); directly concatenating raw text embeddings degrades decision tree performance (XGBoost and LightGBM PR-AUC drop to 0.3893 and 0.4030); whereas an end-to-end multimodal fine-tuning architecture (Transformer E2E FineTune) utilizing layer-wise parameter freezing and differential learning rates reverses text negative transfer, achieving the highest AUROC of 0.8288 +/- 0.0110, PR-AUC of 0.4373 +/- 0.0310, and F1-Score of 0.4757 +/- 0.0196. Operational indicators supply independent risk signals, laying an engineering foundation for high-utility clinical decision support tools.

0.46