Abstract

A brain MRI scan can carry an unknown mix of artifacts, so restoration has to be blind, yet most deep-learning methods are built to correct one known artifact. We present Dx-Rx, an agent in which a multimodal large language model (MLLM) measures suspected artifacts before it repairs them. To our knowledge, it is the first agent to restore whole 3-D MRI volumes, whereas earlier MRI agents restore 2-D slices. In a loop, it looks at slices of the 3-D volume, calls five diagnostic tools (noise, spike, ghosting, bias field, motion) and four restoration tools in any order it chooses, checks each repair, can return to any earlier version to change the order, and ends with a radiology-style report of its diagnostic reasons, the repairs it applied and their results. We simulated up to five artifacts on 148 whole 3-D T1-weighted volumes, at levels calibrated to radiologists' grades of real scans. An MLLM that only looked at the image, as earlier MRI agents do, removed at most 19.7 % of the artifact error. With the best of five MLLMs, Dx-Rx removed a mean 64.5 %, nearly matching the 64.6 % of the same tools given the ground-truth artifacts, which are never known for a clinical scan. With all five models, it made no volume worse and was on par with or better than an expert rule-based pipeline built from the same tools (62.3 %). Code and demo are public at https://itu-biai.github.io/measure-before-you-repair.

Comment
5 pages, 3 figures, 4 tables. Submitted to ISBI 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

eess.IV cs.CV ·2026-08-28 ·Dat Tat Mai, Thai Viet Pham, Thu Nguyen Thi Dang, James Jin Kang
similarity 0.71
Abstract

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

0.21

You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution

cs.CV cs.LGphysics.med-ph ·2026-09-29 ·Prathamesh Pradeep Khole, Shreya Handa, Utkarsh Gupta, Razvan Marinescu
benchmark similarity 0.67
Abstract · 24 pages, 10 tables, 8 figures

Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.

0.27

SliceBridge: Context-Consistent Repair of Corrupted Slice Intervals in T1-Weighted MRI

cs.CV ·2026-09-01 ·Jiheng Li, Michael E. Kim, Trent M. Schwartz, Gaurav Rudravaram, Derek B. Archer +4 more
similarity 0.65
Abstract

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.

0.31

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

eess.IV cs.CV ·2026-09-18 ·Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan +3 more
similarity 0.64
Abstract · 18 pages of main text, 2 pages of appendix, 6 figures, and 6 tables (including 2 appendix tables)

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

0.23

UniField++: A Unified Agentic Framework with Loop Reasoning for MRI Field-Strength Enhancement

cs.CV ·2026-10-16 ·Yiyang Lin, Chenhui Wang, Tianliang Yao, Pengli Zhu, Shuaibo Li +3 more
code/data similarity 0.61
Abstract · 10 pages, 6 figures, 8 tables

MRI field-strength enhancement seeks to combine the accessibility of low-field scanners with the image quality of high-field scanners. Yet, existing methods remain prone to anatomical hallucinations, as uniform processing leaves difficult brain regions insufficiently examined and scarce paired data limit their learning of how tissue contrast and anatomical visibility change across field strengths. To address these challenges, we propose UniField++, a two-agent framework that unifies enhancement tasks across multiple field-strength transitions, including 64mT-to-3T and 3T-to-7T. Unified learning allows both the VLM-based planner and the flow-matching-based enhancer to draw on field-dependent image characteristics observed across tasks, rather than relying on a single transition. Trained with radiologists' annotations of hallucination-prone regions and corresponding correction plans, the planner predicts regional risk and formulates targeted restoration strategies. Guided by these plans, the enhancer performs loop reasoning along the flow-matching trajectory, repeatedly processing high-risk regions for additional refinement. Together, cross-transition learning and risk-guided refinement support anatomically faithful enhancement across field strengths. Across the evaluated tasks, UniField++ improves PSNR by an average of 2.74 dB and SSIM by 14.05 percentage points over comparison methods, with corresponding gains of 3.97 dB and 13.92 percentage points over the ablation baseline. It also maintains enhancement quality on an external cohort with an unseen field strength and improves downstream whole-brain segmentation Macro Dice by an average of 0.1457 over the original low-field images. Code is available at https://github.com/CUHK-AIM-Group/UniField_plusplus.

0.31

VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection

cs.CV ·2026-10-30 ·Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
published similarity 0.61
Abstract · Accepted for WACV 2027

Reconstruction-based anomaly detection no longer fails at reconstruction. Generative models produce high-quality pseudo-healthy reconstructions, and the remaining difficulty is the step of scoring residuals. The residual between a scan and its reconstruction has two indistinguishable sources, genuine pathology and the anatomical variation that separates one healthy brain from another. Scoring against a single reconstruction treats both as anomalous, inflating false positives where healthy anatomy varies most while small or subtle lesions are lost in the surrounding reconstruction error. We identify the missing quantity as the predictive variance, how much a healthy reconstruction can vary at each location. We introduce VariaFlow, which estimates this variance from an ensemble of mask-guided restorations under an unconditional flow matching prior, each started from a different noise initialization, and which normalizes the residual by the resulting standard deviation. Few-step flow matching keeps the ensemble computationally affordable, and restoring at two spatial scales captures lesions of different size. Across three brain MRI datasets spanning stroke and tumor, VariaFlow is trained once on healthy anatomy and generalizes across all three, attaining the highest AUROC (0.94, 0.80, 0.78) on each and the highest AUPRC on both cross-domain datasets, exceeding the strongest baseline by 37% and 50%. Under domain shift, the same baseline drops by up to 52% in AUPRC, whereas VariaFlow stays more stable and achieves the best small-lesion Dice on all three datasets.

0.29

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.61
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.60
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24