CS Paper Radar

Multi-experiment identification from short repeated transients:the human response to pushes in a Tai Chi posture

Emmanuel Witrant, Olivier A. J. Martin, Pascal Bellemain

eess.SY ·submitted 2026-11-03 12:09 UTC · v1

Abstract

The effect of Tai Chi postures on the mechanical response of the body to external pushes is usually assessed with clinical balance scores, which say little about the underlying dynamics. We identify, for five subjects and eight postural conditions, linear models from the mechanical work transferred by a pendulum hitting the forearm to the change of the antero-posterior ground reaction force. Each trial contains 10 to 16 impacts, and each impact yields a transient of 0.55\,s only. Building on earlier analyses of these data, we improve the processing chain in three ways. The input is related to the energy lost by the pendulum and its repeatability is quantified. The output is defined component-wise, which makes it independent of the zeroing of the force plate. Finally, the impacts are stacked in a multi-experiment least-squares problem and validated on unseen impacts. Tenth-order ARX models then reach a median leave-one-impact-out fit of 65\%, against 72\% for the repeatability of the response itself, and never require stability enforcement, unlike estimation on averaged impacts. Closing the eyes lengthens the identified delay by about 70\,ms in all subjects, and the Tai Chi posture increases the antero-posterior force transmitted per joule in four of five subjects. Surface EMG envelopes show a tonic co-activation of the lower-leg muscles in this posture, a smaller reactive triceps burst and a fast habituation of the tibialis response. Together, they point to a stiffer, anticipatory postural strategy.

Closest papers

Nearest neighbours by meaning across the whole index.

Angular momentum analysis on Karate roundhouse kicks: a longitudinal case study

cs.RO ·2026-09-21 ·Jan C. L. Lau, Christian Mele, Jonathan Feng-Shun Lin, Katja Mombaur
similarity 0.56
Abstract

Human gait in reality extends beyond straight-line walking, with some situations even requiring drastic back-and-forth rotations. A smooth and stable execution may seem intuitive, but the underlying mechanics remains unknown. The Karate roundhouse kick may be an extreme case of exhibiting dynamic back-and-forth rotations, but investigating the angular momentum (AM) management can potentially inform stability analysis in dynamic human motions and smoother gait in robots and exoskeletons. This paper introduces two new AM-based measures and analyzes AM-related variables to study the target-less retractable back-leg Karate roundhouse kick. The purpose is to understand the underlying AM management, analyze the differences between stable and unstable kicks, and investigate how these variables and measures change over time with improvement. A one-year longitudinal study was conducted with the first author as a Karate student, and a Karate instructor was also recruited for one session as an expert, whose data is used for comparison. Results show that unstable kicks have higher peak total AM before Strike and smaller braking peak after Strike. The proposed AM-based measures are able to identify the cause of some unstable kicks, though no clear distinction could be made between stable and unstable kicks since kicks can be unstable for different reasons. Nonetheless, the proposed measures can be applied as performance measures to analyze other types of dynamic motions. To incorporate them as stability criteria, however, it is recommended to also consider their coordination with time, kinematics, and center of pressure.

0.23

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

cs.RO cs.LGeess.SP ·2026-11-14 ·Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong
similarity 0.53
Abstract · 8 pages, 5 figures, 3 tables. Submitted to IEEE Robotics and Automation Letters (RA-L)

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

0.18

A generalist policy for muscle-driven control across individual musculoskeletal models

cs.RO ·2026-10-27 ·Bozhao Wang, Yinglei Zhu, Zhengqing Li, Zhiyuan Zhang, Weiming Kang +5 more
similarity 0.52
Abstract · 17 pages, 7 figures. Project website: https://woodater-thu.github.io/MyoAcross/ Bozhao Wang and Yinglei Zhu contributed equally to this work

Differences in musculoskeletal morphology challenge policy reuse across individual models. Here we present MyoAcross, a framework that combines individual musculoskeletal model construction, morphology-conditioned policy learning and virtual model augmentation to enable muscle-driven reference-motion tracking without individual fine-tuning. Across 31 held-out individual models, MyoAcross achieves 99.24% completion and reduces tracking error by 22.60% relative to an unconditioned multilayer perceptron. Policy reuse extends to models of 22 held-out individuals constructed from single-image shape estimates, measured height and body mass, and, with asymmetry augmentation, to models with unilateral lower-limb shortening. Comparisons with measurements from 120 additional individuals show agreement in vertical ground reaction force waveforms and channel-dependent agreement between simulated muscle activations and electromyography. These results establish a common control framework for comparative simulations of movement across individual musculoskeletal models.

0.38

Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model

cs.RO ·2026-11-18 ·Lisette Masselink, Xiaolong Zhu Thomas George Thuruthel, Mohamed Irfan Refai
similarity 0.51
Abstract

The human-exoskeleton interaction interface, consisting of the exoskeleton attachment and the underlying human soft tissue, can affect the transfer of assistance. MuJoCo's \textit{flexcomp} has been previously used to model the soft tissue, but its accuracy has not been benchmarked against a finite element model. We benchmarked the \textit{flexcomp} Saint Venant-Kirchhoff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: \textit{case 1}) spherical indentation, \textit{case 2}) compression, and \textit{case 3}) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which could be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Although MuJoCo's \textit{flexcomp} offers a combination of soft-tissue modelling and multibody dynamics, the limitations regarding the stiffening and hysteresis should be addressed to be used for the analysis of the human-exoskeleton interaction interface.

0.27

Subject-Held-Out Evaluation of Deep Ground Reaction Force Estimators Across Two Laboratories: Leakage and Cross-Laboratory Transfer

cs.LG eess.SPq-bio.QM ·2026-11-11 ·Hernan David Santos, Yinong Chen, Yu Ding, Xudong Zhang, Jian Tao
code/data similarity 0.51
Abstract · 15 pages (9 main + 6 supplementary), 5 figures. Submitted to IEEE Journal of Biomedical and Health Informatics. Code and run outputs: https:…

Deep networks that estimate ground reaction forces and centers of pressure from motion-capture markers are validated within one laboratory, in a seldom-stated coordinate frame, and sometimes with trial-level splits that put the same person in the training and the test set. We measured what each practice costs, and whether such models transfer between laboratories. Three sequence models (convolutional, convolutional-recurrent, and convolutional-transformer) were evaluated on two independent datasets, locomotion (6 subjects) and occupational patient handling (10 subjects), under one pipeline, one tuning procedure, three seeds, and four protocols: trial-level split, leave-one-subject-out, pooled two-laboratory training with matched held-out subjects, and cross-laboratory transfer. At a fixed configuration, trial-level splits overstated the subject-held-out coefficient of determination by +0.040 to +0.194; on occupational data the overstatement exceeded every difference between architectures. With subjects held out, the three models reached values between 0.583 and 0.804; the leader differed between datasets, and gaps lay within subject-to-subject variability. Pooling the laboratories changed neither dataset on matched subjects. Transfer between laboratories was below chance in both directions, including the vertical force, which no in-plane rotation can affect. Leaving force targets in the plate frame while inputs were heading-aligned cost 0.57 of locomotion anteroposterior-force explained variance, enough to make that force look hardest; a Newton's-law correlation detected the mismatch before training. Split protocol and target frame changed reported accuracy more than architecture did. Learned force estimators should be validated with subjects held out, checked for frame consistency before training, and tested across laboratories before deployment claims are made.

0.37

Robot-Induced Bias in Movement Smoothness Metrics for Rehabilitation: Quantification and Correction in Simulation

cs.RO q-bio.QM ·2026-11-11 ·David Regev, Alex Scherbakov, Eran Beeri Bamani
benchmark similarity 0.49
Abstract · 7 pages, 4 figures, 2 tables. Submitted to the 2027 IEEE International Conference on Rehabilitation Robotics (ICORR)

Robot mechanics can bias kinematic measures of recovery and limit comparisons across rehabilitation devices. We developed a closed-loop human-robot simulation calibrated to published healthy and stroke group kinematics. Paired runs held motor-control parameters and movement plans fixed to quantify bias in seven metrics relative to a low-impedance reference, normalized using external repeatability benchmarks. Within a subset informed by published device specifications, median log dimensionless jerk (LDLJ) bias was 0.93 and 1.79 benchmark units for stroke and healthy profiles, respectively. Sobol analysis identified Coulomb friction and apparent mass as leading contributors; LDLJ bias persisted across 11 robustness variants. LDLJ bias increased as simulated movements became less fragmented. If recovery similarly reduces fragmentation, this effect could partly mask improvement in measured smoothness. Correction combining identified robot dynamics and observed metrics with gradient-boosted trees reduced median normalized absolute error from 0.77 to 0.10 for LDLJ and from 0.24 to 0.08 for spectral arc length (SPARC) in the device-informed subset of a random 20% hold-out. Median smoothness residuals remained at or below 0.15 benchmark units across four separately held-out parameter regions. Under an alternative controller, LDLJ error decreased from 1.60 to 0.17 without retraining, although transfer varied across metrics. These simulation results support mechanical characterization and movement-dependent correction toward more comparable robotic assessments, motivating validation in patients.

0.26

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

cs.CV cs.AI ·2026-08-28 ·Mohammad Arif Ul Alam
similarity 0.49
Abstract

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths (R-square = 0.92 in development validation and approximately 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only +/-5% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.

0.24

Toward Fast Human Reaction Modeling from High-Frequency Digital Interaction Data

cs.AI cs.LG ·2026-10-26 ·Emanuel Dopater, Daniel Gavlas, Lukáš Jochymek, Kannan Paul, Miloslav Szczypka +5 more
similarity 0.48
Abstract

We investigate whether limbic-like signatures of rapid, salience-driven behavior can be identified in high-resolution Counter-Strike 2 telemetry. This exploratory study introduces Ego-Knowledge, a leak-reduced reconstruction of each player's plausible perceptual state, supported by a millisecond-precision visibility engine and a reaction-centered extraction pipeline. Using a neuroscience-motivated 60--120 ms window, we derive coarse fight-or-flight labels from visibility- and damage-triggered events, with back-damage cases enabling constrained reaction-time analysis and manual label checks. We train two telemetry-native models using only information available by the trigger: EMBER (gradient boosting) and ORBIT (a custom transformer). On the full validation set, EMBER achieves 73.5% accuracy and ORBIT 71.2%, versus a 51.5% majority-class baseline, and both generalize to held-out players. The strongest LLM baseline achieves 62.7% on 1,000 validation cases; on these same cases, EMBER (73.6%) and ORBIT (70.9%) perform better (McNemar p=1.3e-9 and 1.5e-6, respectively), with orders-of-magnitude lower inference time and cost, though the comparison is not compute-matched. Including a short post-trigger window changes forecasting into early response recognition, raising accuracy monotonically to 85.15%. We propose this curve as a candidate probe of the transition from rapid to deliberative control, but roughly uniform per-tick gains do not establish that interpretation. The neuroscience framing is hypothesis-generating, not mechanistic: physiological ground truth, suitable control distributions, and reverse-inference limitations remain open. We outline extensions to auditory reconstruction, larger datasets, and telemetry-native foundation models.

0.22