CS Paper Radar

Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model

Lisette Masselink, Xiaolong Zhu Thomas George Thuruthel, Mohamed Irfan Refai

cs.RO ·submitted 2026-11-18 07:59 UTC · v1

Abstract

The human-exoskeleton interaction interface, consisting of the exoskeleton attachment and the underlying human soft tissue, can affect the transfer of assistance. MuJoCo's \textit{flexcomp} has been previously used to model the soft tissue, but its accuracy has not been benchmarked against a finite element model. We benchmarked the \textit{flexcomp} Saint Venant-Kirchhoff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: \textit{case 1}) spherical indentation, \textit{case 2}) compression, and \textit{case 3}) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which could be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Although MuJoCo's \textit{flexcomp} offers a combination of soft-tissue modelling and multibody dynamics, the limitations regarding the stiffening and hysteresis should be addressed to be used for the analysis of the human-exoskeleton interaction interface.

Closest papers

Nearest neighbours by meaning across the whole index.

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

cs.RO ·2026-10-02 ·Neethan Ratnakumar, Mariya Tohfafarosh, Xianlian Zhou
similarity 0.59
Abstract

Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

0.14

Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry

cs.AI cs.CGcs.CV ·2026-08-21 ·Madina Kojanazarova, Sidaty El Hadramy, Philippe C. Cattin
similarity 0.57
Abstract

Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency.

0.31

Optimization Design and Simulation Validation of a Variable Stiffness Actuator Based on a Crossed Four-Bar Mechanism

eess.SY ·2026-09-16 ·Yuanlong Ji, Ruizhe Jiang, Xiangyu Xie, Junheng Lin, Dongrun Jin +1 more
published similarity 0.55
Abstract · 7 pages, 5 figures

This paper presents a bio-inspired antagonistic variable stiffness actuator (VSA) based on two crossed four-bar compliant transmission elastic units (CFB-CTEs). The design addresses the difficulty of combining nonlinear elastic shaping with low structural inertia in antagonistic VSA mechanisms. Inspired by the crossed constraint behavior of the anterior and posterior cruciate ligaments during knee flexion, the proposed actuator uses geometric transmission, elastic energy storage, and bilateral antagonistic arrangement to shape the output torque and equivalent stiffness. A multi-objective optimization model is established to balance torque tracking accuracy, equivalent inertia, and mass. The selected compromise design achieved a torque root-mean-square error (RMSE) of $0.883~\mathrm{N\,mm}$ and a total mass of $50.2~\mathrm{g}$. Its average equivalent inertia was reduced by about 78% compared with an independent torque-only optimized design. An ADAMS multibody model was further built to verify the structural response under single-input, opposite-input, and same-input conditions. The results support the feasibility of the proposed crossed four-bar elastic unit as a lightweight nonlinear elastic branch for antagonistic VSAs.

0.68

Gait-Dependent Effects on Quadruped Locomotion for Load-Carrying using Passive Mechanism

cs.RO ·2026-09-10 ·Giovanni B. Dessy, Claudio Semini, Victor Barasuol
similarity 0.54
Abstract

Passive mechanical interfaces offer a lightweight alternative to actuated manipulators for quadruped payload carrying, but their impedance directly couples the payload dynamics with the locomotion pattern. This paper analyzes how passive-arm stiffness-damping selection affects payload-carrying locomotion under different gait and payload conditions. We compare damped and underdamped passive-arm impedance configurations in simulation during flat-ground locomotion. For crawl gaits, where the support polygon remains well defined, the results show that underdamped impedance increases passive-joint oscillations and can reduce the ZMP margin with respect to the support polygon. Trot is retained as a dynamic excitation case for the passive arm, but it is not used for direct ZMP-margin stability comparison. The results are summarized in gait-payload-stiffness-damping maps, where ZMP-margin reduction is evaluated for crawl gaits and trot is retained only as a passive-arm excitation case.

0.44

Design and Analysis of a Nonlinear Parallel Mechanism Coupling for Dynamic Humanoid Legs

cs.RO ·2026-10-12 ·Rohit Kumar, Heiner Peters, Felix Wiebe, Franek Stark, Janne Janzen +3 more
similarity 0.53
Abstract

Humanoids increasingly demand lightweight leg mechanisms for agile, dynamic, and energy-efficient locomotion. Reducing distal inertia through proximal actuation has thus become a common design goal. Yet, compact transmissions that preserve torque capability and efficient force transmission remain hard to achieve. This paper presents a novel series-parallel leg design combining a knee parallel mechanism, an ankle parallel mechanism, and a nonlinear knee-ankle coupling where all actuators placed closer to the hip. As the knee flexes, the coupling passively assists ankle dorsiflexion for foot clearance and, as it extends it assists plantarflexion for push-off, redistributing ankle load through the knee transmission. We derive the coupling's nonlinear transmission models and validate them in simulation and on hardware. The design shows that the shared transmission lets both joints draw on each other's actuator capacity by easing the knee's peak torque demand under load and the ankle's peak speed demand during fast motion. With the leg's proximal actuator placement, the leg achieves an effective reflected mass of 0.37 kg at the foot for a 6 kg leg, demonstrating very low distal leg inertia for dynamic humanoid robots.

0.12

A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits

cs.RO cs.HC ·2026-08-18 ·Anoush Sepehri, Zachary Huang, Raymond de Callafon, Michael T. Tolley, Tania K. Morimoto
similarity 0.53
Abstract

Pneumatic artificial muscles have provided new opportunities to develop upper-extremity soft exosuits for reha- bilitation, augmentation, and assisted daily living. However, the complex dynamics and limited bandwidth of these actuators has made providing responsive assistance based on user intention a longstanding challenge. In this work, we present an inverse-plant control strategy for pneumatically actuated soft exosuits that only relies on kinematic sensing for task-agnostic and dynamic assistance during daily living. We model the human-robot system using a Hammerstein dynamic model, consisting of a Preisach hysteresis model and a linear time-invariant filter, to capture the static and dynamic behavior of the system. We personalize our model to each user using 140 s of data and approximate an inverse to integrate into our control loop. When evaluated on a test rig that emulated a soft assistive exosuit for the wrist, our controller reduced the interaction torque by up to 73% and the activation of key flexor and extensor muscles by up to 47% relative to the condition with no assistance for speeds ranging from 8°/s to 120°/s. Overall, this work presents a control strategy that can provide task-agnostic, dynamic assistance with pneumatically actuated soft exosuits without the need for physiological or force sensors to interpret user intention.

0.19

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.53
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

cs.RO ·2026-11-03 ·Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya +2 more
benchmark similarity 0.53
Abstract · 8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

0.25