CS Paper Radar

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya, Allison M. Okamura, Ava Chen

cs.RO ·submitted 2026-11-03 23:27 UTC · v1
benchmark

Abstract

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

Comment
8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

Closest papers

Nearest neighbours by meaning across the whole index.

A Wearable Pneumatic Device for Continuous, Closed-Loop, Bidirectional Tactile Interaction

cs.RO ·2026-09-01 ·Cosima du Pasquier, Aliyah Smith, Serin Huber, Joshua Phelps, Ilana A. Cohen +3 more
similarity 0.66
Abstract

We present a system of two wearable pneumatic haptic devices that supports continuous, closed-loop, bidirectional tactile interaction at perceptually relevant force and temporal scales. A single device can contain up to twelve pressure sensing channels connected to textile-based pneumatic pouches. Each channel in a device can be used as a sensor, an actuator, or both. As an actuator with integrated sensing, the channel generates stable skin indentation through local closed-loop control. As a sensor, a channel can be mounted (or worn) on any surface, including on a robot gripper or on the human body, and used to measure touch interactions with the environment or a human user. A distributed architecture supports sustained pressure output, rapid dynamic response, and wireless pairing of identical devices in a system to transmit and reproduce tactile pressure signals in real time. Device-level characterization demonstrates force bandwidth exceeding 30 Hz, rapid and well-damped step responses, and extended pressure retention compared to prior compact pneumatic platforms. Human studies show that pressure-based fingertip feedback enables discrimination of force and stiffness, improves teleoperated manipulation by reducing applied pressures by up to 23.1% and task duration by up to 27.4%, and lowers subjective mental workload by 18.8%, particularly under visually constrained conditions. By unifying tactile sensing and haptic feedback within a single pneumatic modality, the device provides a practical foundation for bidirectional touch interaction in teleoperation.

0.14

Hugging Suit: Pneumatically-Actuated System Design for Remote Haptic Experiences

cs.HC cs.ET ·2026-10-06 ·Russian, Wu, Luke Hespanhol, Marius Hoggenmueller, Hannes Waldschütz +1 more
published similarity 0.59
Abstract · Accepted Work in Progress at the IEEE World Haptics Conference 2025, July 8-11, 2025, Suwon, South Korea. 2 pages, 1 figure

The COVID-19 pandemic emphasised the importance of remote emotional communication and highlighted a gap in existing technologies that lack haptic channels. While video calls maintain visual and auditory presence, they cannot convey the emotional depth of physical contact, especially hugging, a universally recognised form of intimacy and support. To explore this challenge, we developed the Hugging Suit, a pneumatically-actuated wearable system that enables users to simulate and receive remote hugs in real time. Unlike prior haptic systems that focus solely on tactile sensation, our approach integrates both technical and experiential considerations. The system integrates a programmable Air Actuator Matrix (AAM), a portable high-pressure pneumatic unit, and a fabric-based pressure sensor layer, enabling precise, wearable haptic feedback while remaining lightweight and mobile. Guided by a Research through Design (RtD) methodology, we iteratively refined the prototype to improve tactile resolution, overall usability, and user comfort, while introducing modular components to support flexible and scalable haptic configurations. In parallel, we explored how specific contextual factors, such as lighting, privacy, and the visibility of the remote partner, might shape the emotional and perceptual experience of receiving a remote hug. Preliminary feedback suggests that low-lit, private spaces, especially when users could also see their remote partner via video, improved emotional engagement and comfort during mediated haptic experiences. Our low-cost, maker-space-friendly approach contributes to affective haptics applications in long-distance relationships, emotional regulation, and remote therapeutic support.

0.29

Haptic Probing for Subsurface-Aware Force Distribution on Layered Soft Tissue

cs.RO ·2026-11-17 ·Lei Shi, Xiaoyu Wang, Cheng Zhou, Yongjian Liu, Jing Wang +3 more
position similarity 0.58
Abstract

Force-regulated contact with layered soft tissue fails most often where the subsurface composition changes: controllers infer the substrate from the loading signal alone, so the estimate guiding them lags the change---more acutely, we argue, over compliant than over bone-backed tissue. We remove that lag with a separate haptic channel. Under a light preload, a brief low-amplitude excitation lets the local dynamic admittance discriminate muscle from bone-backed tissue relative to a per-subject baseline, before task force is applied---active haptic sensing used to commit a control decision rather than to characterise tissue. A force- and tactile-driven distribution law then consumes that regime throughout execution: an instantaneous allocation equalises pressure across the engaged fingertips, while the regime sets the admissible pressure and hence the area the hand must recruit to deliver the target force---making patch area a controlled variable rather than a by-product. Probing, switches and recruitment are priced in a partitioned passivity budget, so safety monitoring cannot suppress the probe and a refused recruitment forfeits force tracking rather than the pressure bound. We report force tracking and pressure uniformity over curved, migrating contact on three human subjects, with regime labels from anatomical landmarks.

0.21

History-Aware Force Sensing and Tunable Stiffness in a Pneumatic Kresling Origami Cell

cs.RO ·2026-11-01 ·Hengyi Zhou, Jiaqi Wang, Yilin Ma, Dezhong Tong, Xiaonan Huang
similarity 0.57
Abstract

Mechanical hysteresis and pneumatic loading complicate contact force estimation from deformation measurements in soft robots. This work presents a 3D-printed polyether block amide (PEBA) Kresling cell with magnetic angular sensing that supports three operating modes: force sensing at zero gauge pressure, force sensing with tunable stiffness under gauge positive pressure, and self-sensing actuation under negative gauge pressure. A multiscale gated recurrent unit (GRU) network estimates contact force from angular histories to account for the the combined effects of geometric deformation and material response. At zero gauge pressure, the model achieves a test RMSE of 0.76~N. Positive gauge pressure approximately doubles the average axial loading stiffness at +20~kPa over the first 3~mm of compression, while pressure-specific models maintain RMSEs below 0.93~N. Under negative gauge pressure, an energy-based compensation model enables contact force estimation using the the model trained at zero gauge pressure, achieving RMSEs of 1.66--2.10~N under quasi-static conditions. These results demonstrate a compact approach to combining force feedback, tunable axial stiffness, and self-sensing actuation in soft origami systems.

0.36

A Reconfigurable Fabric Based Pneumatic Actuator with Button Fastened Constraint Modules for Multi Mode Actuation

cs.RO ·2026-10-08 ·Kentaro Kimura, Hiroki Ishizuka, Yusuke Sakaue, Sei Ikeda, Osamu Oshiro
similarity 0.56
Abstract · IEEE Access in Revision

Soft pneumatic actuators are widely used in soft robotics. However, their actuation modes are typically fixed by internal chamber designs or reinforcements, making post fabrication reconfiguration difficult. This paper presents a reconfigurable fabric-based pneumatic actuator that enables rapid, tool free, and reusable switching among multiple actuation modes by attaching constraint fabric modules to a buttoned textile sleeve. By rearranging low-stretch constraint parts on a single actuator body, the proposed system realizes four actuation modes isotropic expansion, contraction, bending, and twisting without redesigning or disassembling the actuator.We further introduce an attachable capacitive fabric-based tactile sensor module that can be mounted at arbitrary locations on the actuator surface for task dependent contact sensing. Experiments demonstrated an elongation ratio of 1.2, a maximum bending angle of approximately 60 degrees, and a twisting angle of approximately 90 degrees at 24 kPa, while achieving blocking forces exceeding 10 N across all modes. The tactile sensor exhibited a monotonic, force-dependent increase in capacitance with low hysteresis (approximately 12%) and stable cyclic responses under preload. Finally, we constructed soft robotic arms composed of multiple actuators and demonstrated in situ motion reconfiguration for grasping by changing the attached constraint patterns. These results indicate that the proposed modular constraint and sensing framework improves the functional adaptability of fabric-based soft robots while preserving a simple, robust actuator structure.

0.23

Intuitive Directional Sense Presentation to the Torso Using McKibben-Based Surface Haptic Sensation in Immersive Space

cs.HC cs.RO ·2026-08-10 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
top venue similarity 0.55
Abstract · This is the accepted version of an article published in IEEE Transactions on Haptics 18(1), 244-254 (2025). DOI: 10.1109/TOH.2024.3522897. O…

In recent years, systems that utilize immersive space have been developed in various fields. Immersive spaces often contain considerable amounts of visual information; therefore, users often fail to obtain their desired information. Therefore, various methods have been developed to guide users toward haptic sensations. However, many of these methods have limitations in terms of the intuitive perception of haptic sensation and require practice for familiarization with haptic sensation. Fabric actuators are wearable haptic devices that combine fabric and McKibben artificial muscles to provide wearers with surface haptic sensation. These sensations can be provided to a wide area of the body with intuitive perception, instead of only to a part of the body. This paper presents a novel air pressure adjustment method for whole-body motion guidance using surface haptic sensations provided by a wearable fabric actuator. The proposed system can provide users with a directional sense without visual information in an immersive space. The effectiveness of the proposed system was evaluated through subject experiments and statistical data analysis. Finally, a directional sense presentation was conducted for users performing micromanipulations in a mixed-reality space to demonstrate the applicability of the proposed system for teleoperation.

0.73

GraspPressure: Understanding Pressure Input With Busy Hands

cs.HC ·2026-10-29 ·Anand Kumar, Aditya Shekhar Nittala
published similarity 0.55
Abstract · To appear in the Proceedings of the ACM on Human-Computer Interaction (PACM HCI), presented at ACM Interactive Surfaces and Spaces (ISS 2026…

In many real-world scenarios, users interact with digital systems while their hands are partially occupied, such as when holding tools or everyday objects. Prior work on busy-hand interaction has focused on microgestures and motion-based techniques, which rely on finger articulation or relative movement. In situations where a stable grasp is required, such as handling fragile, heavy, or precision objects, such motion can be undesirable or impractical. Pressure-based input offers a complementary modality that enables interaction without changing finger pose, yet its use while holding objects has received limited empirical attention. To explore this, we conducted two within-subject experiments examining users' ability to perform controlled pressure selections and analyzing finger-specific performance across different grasps and geometries. Results indicate that participants can reliably perform pressure-based selections in these conditions, achieving high success rates (92.7% on average) with low selection times (1.74s on average). Our findings characterize the potential of pressure input as a complementary microinteraction modality under grasp-constrained, busy-hand scenarios.

0.28

Pneumatic Units for Logic-based Sequential Excitation (PULSE) in Wearable Haptic Devices

cs.HC cs.RO ·2026-08-20 ·Jessica Healey, Anoush Sepehri, Michael T. Tolley, Tania K. Morimoto
similarity 0.55
Abstract · 9 pages, 6 figures

Soft, wearable robotic devices can deliver haptic feedback to support a wide range of tasks, such as extended reality, training various skills, and rehabilitation. Pneumatic actuation can deliver complex haptic feedback, is lightweight and compliant, and can be incorporated into textiles, making it promising for wearable applications. These soft pneumatic devices, however, typically require a valve and input for each pneumatic actuator, making it challenging to develop fully portable devices for at-home use. In this work we present a pneumatic unit for logic-based sequential excitation (PULSE). The PULSE is a flat, textile-based pneumatic actuator with embedded fluidic logic. By combining these actuators into a fluidic ring oscillator, we decreased the typical amount of required pneumatic inputs for a haptic forearm sleeve by 60%, with the ability to scale. We built the ring oscillator by optimizing design variables to reach desired periods of oscillation. We demonstrated a set of tactile stroking cues with periods ranging from 1.16 to 1.56 s and forces ranging from 1.07 to 2.04 N. We assessed the sleeve's ability to render differentiable, pleasant, and continuous haptic cues in a user study. The forearm sleeve containing PULSEs successfully delivered four directional cues and guided users to target wrist angles with fast reaction times, low overshoot amounts, and a 93.3% average accuracy of correct initial directions.

0.18