CS Paper Radar

CardioDrift: Automatic Cardiac Motion Tracking on a 3D Atlas Mesh via Shape-aware Coherent Point Drift with Slice Shift Correction

Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S. L. Ho, Fani Deligianni, Ali Gooya

cs.CV ·submitted 2026-11-04 15:39 UTC · v1

Abstract

Automatic cardiac motion tracking from cine cardiac magnetic resonance (CMR) imaging is essential for quantifying myocardial motion abnormalities associated with cardiovascular disease. Existing methods fall into two groups: those that represent motion without anatomical correspondence across subjects and therefore limit inter-subject motion assessment; and those that represent motion with globally corresponding points, which typically require a time-consuming and error-prone semi-automatic step to fit a cardiac atlas to the subject space. To address these limitations, this study proposes CardioDrift, a fully automatic, atlas-based probabilistic framework that represents subject-specific cardiac motion on a 3D atlas mesh with globally corresponding points. The Coherent Point Drift (CPD) formulation is generalised to jointly register the atlas surfaces of multiple cardiac regions to the anatomically corresponding contours extracted from cine CMR segmentation maps throughout the cardiac cycle. Slice-shift correction is embedded in the same probabilistic model, estimating slice-wise translations that suppress the misalignment artefact limiting atlas-fitting accuracy. Evaluation on 1301 randomly selected UK Biobank subjects and the M&M dataset, CardioDrift attains Dice similarity coefficients (DSCs) of $92.23\pm8.70\%$, $82.11\pm7.56\%$, and $88.69\pm4.13\%$ for the left ventricle (LV), myocardium (Myo), and right ventricle (RV), exceeding the strongest baseline on every distance and overlap metric of both datasets.

Closest papers

Nearest neighbours by meaning across the whole index.

CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and Segmentation

cs.CV ·2026-11-13 ·Zhi Chen, Le Zhang
hot direction similarity 0.67
Abstract

Cardiac cine MRI provides time-resolved visualization of cardiac motion and is essential for evaluating ventricular function and anatomy. In routine clinical acquisition, however, cine sequences are frequently temporally sparse or degraded by arrhythmia, motion, and scan-time constraints, which can hinder reliable quantification and downstream analysis. We present CardioTrace, a motion-aware cine synthesis framework that generates a full cardiac cine sequence from limited input while explicitly modeling and tracing cardiac motion. CardioTrace couples two complementary pathways: a pixel-translation branch that directly predicts cine frames in a residual formulation, and a flow-field branch that estimates time-resolved deformation fields from a reference phase to provide interpretable motion correspondences across frames. To further preserve anatomical plausibility, a segmentation branch supervises clinically meaningful cardiac structures at key phases, and a cross-branch consistency objective encourages the synthesized appearance dynamics to follow the explicit motion guidance, mitigating temporal drift and unrealistic shape transitions over long sequences. The framework also supports prompt-style conditioning to incorporate auxiliary patient or acquisition information, improving robustness across heterogeneous multi-center data. Experiments on public cardiac cine MRI datasets demonstrate that CardioTrace improves perceptual quality and temporal coherence over representative GAN- and diffusion-based baselines, while better preserving ventricular morphology throughout the cardiac cycle. \textit{Our codes are available after review}.

0.17

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.66
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching

cs.CV ·2026-10-06 ·Shiyi Wang, Ruochen Sun, Xiang Li, Peirong Liu, Fangxu Xing
benchmark similarity 0.62
Abstract

Cine cardiovascular magnetic resonance (CMR) captures the cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition requires electrocardiogram (ECG) gating and repeated breath holds. Visual realism alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG. To capture asymmetric systolic and diastolic dynamics, it represents the cardiac cycle as a piecewise linear phase anchored at ED and end-systolic (ES) time points. At inference, a population-level canonical template supplies this phase without patient-specific temporal information. A phase-conditioned rectified flow model generates a cardiac motion trajectory in latent space. Radial Contraction Decomposition converts each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Each frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the lowest EF mean absolute error, the only positive left-ventricular volume-curve $R^2$, and the best distributional quality among compared methods. Ablations confirm each component's contribution. Downstream evaluations demonstrate the utility of the synthesized sequences and displacement fields for segmentation, pathology classification, label propagation, and myocardial strain analysis.

0.23

Local2Mesh: Spatially Localized Contour-to-Mesh for Left Ventricular Reconstruction from Sparse 2D Cardiac MRI

cs.CV cs.AI ·2026-10-05 ·Haoyu Wu, Ling Lin, Pascal Lefèvre, Ruizhe Li, Xiaowu Sun
code/data similarity 0.62
Abstract · submit to ICASSP 2027

Three-dimensional (3D) left ventricular (LV) reconstruction from sparse cardiac magnetic resonance (CMR) imaging remains challenging due to inter-slice misalignment and insufficient local spatial information between slices. Global aggregation of contour features may obscure local contour-to-surface relationships. We propose Local2Mesh, a spatially localized contour-to-mesh framework that deforms a template mesh to reconstruct 3D LV geometry from sparse 2D contours without 3D mesh annotations. The framework introduces geometry-aware alignment to correct inter-slice misalignment and a plane-aware Local Router that routes contour features to template vertices using vertex-to-plane distances. Local and global contour features then jointly guide graph-based template deformation for 3D LV reconstruction. Experiments on two public datasets, M\&Ms-2 and ACDC, demonstrate superior geometric reconstruction and functional estimation over existing methods. Zero-shot transfer from M\&Ms-2 to ACDC demonstrates strong cross-dataset generalization. Reconstructed meshes also improve disease classification over sparse contours, supporting their utility for downstream cardiac analysis. These results demonstrate that combining geometry-aware alignment with local contour-to-vertex modeling improves LV reconstruction from sparse 2D contours and supports downstream cardiac analysis. The code is available at https://github.com/hwu918945-alt/loca2mesh.

0.24

Learning to Beat: Phenotype-Guided Latent Flow with Regional Motion Priors for Biventricular Motion Synthesis

cs.CV cs.AI ·2026-08-20 ·Xuan Yang, Xiaohan Yuan, Hao Li, Lingyu Chen, Yanan Liu +2 more
similarity 0.61
Abstract · 14pages, 10 figures

Full-cycle biventricular geometry is essential for characterizing cardiac function. However, dense and temporally consistent 3D+t biventricular meshes are not routinely available, whereas end-diastolic (ED) anatomy can often be obtained reliably. We therefore investigate full-cycle biventricular motion synthesis from a single ED mesh. This task is challenging because cardiac deformation is spatially heterogeneous and phenotype dependent, while conventional global generative models often obscure localized motion patterns. In this study, we propose a region-specific and phenotype-adaptive framework that integrates motion-informed functional parcellation with conditional latent flow. A functional partition learned from reconstructed motion organizes the ventricular surface into regions with coherent dynamics and enables topology-aware regional feature exchange. A phenotype-conditioned rectified-flow model subsequently maps the ED anatomy to full-cycle motion latents through fine-grained conditioning and prototype-routed motion adapters. An optional control branch further incorporates available motion descriptors for controllable synthesis. Experiments on ACDC, M\&Ms, and M\&Ms-2 demonstrate consistent improvements in geometric accuracy and functional fidelity. Under ED-only synthesis, our method achieves biventricular ASSD, HD95, and vRMSE of \(1.49\pm0.34\)~mm, \(3.77\pm1.06\)~mm, and \(3.31\pm1.03\)~mm, respectively, outperforming all competing methods. Complementary functional and robustness evaluations further demonstrate that the synthesized sequences preserve physiologically plausible ventricular dynamics and generalize across cohorts and disease phenotypes. The code will be released publicly upon acceptance of the manuscript for publication.

0.27

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.61
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.60
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.58
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33