CS Paper Radar

CT-RespGeomLib: Deterministic reconstruction of CT airway masks into editable,port-matched lumen geometry

Nichula Wasalathilaka, Kevin Dawson, Chinthaka Jacob, Mervyn Parakrama Ekanayake, Roshan Godaliyadda

eess.SY ·submitted 2026-11-12 15:48 UTC · v1

Abstract

Patient-specific airway modelling requires geometrically consistent lumen surfaces with identifiable boundaries and support for controlled anatomical modifications. We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence. The parametric representation further enables localised modelling of airway stenosis and dilation without re-segmentation. Evaluated on 42 reference airway masks from ATM22 (15 cases) and AeroPath (27 cases), the framework produced 37 topologically accepted reconstructions, with a median port-to-loop distance of 0.123 mm across 2174 matched ports. Reconstructed and reference equivalent radii showed strong agreement ($R^2 = 0.976$), with a mean bias of -0.414 mm arising primarily from the circular, inscribed-radius representation. Controlled pathology modelling generated 40 variants across five patient-specific geometries, including 25-75% stenosis and 50% dilation at tracheal and main-bronchus locations. Prescribed radius changes were reproduced with a mean absolute ratio error of 0.0056, while the median 95th-percentile deviation outside the modified region was 0.111 mm. Downstream applicability was demonstrated through volume meshing and an OpenFOAM simulation with individually prescribed model-based resistance conditions at 62 outlets. Although additional surface preparation may be required for numerical meshing, CT-RespGeomLib provides a reproducible framework for CT-derived airway reconstruction, quantitative boundary validation and controlled geometric pathology modelling.

Closest papers

Nearest neighbours by meaning across the whole index.

Anchored Fusion for Automated Airway Segmentation in Pediatric and Adult CT

eess.IV cs.CV ·2026-10-28 ·Huseyin Umut Isik, Ege Mert Balcik, Duygu Atasoy, Asutosh Sahu, Seyda Ertekin +1 more
code/dataunusual similarity 0.58
Abstract · 9 pages, 3 figures, 2 tables. Code, weights and web application: https://github.com/quin-med-harvard-edu/airway-seg

Airway segmentation from chest CT enables branch-level measurement of airway size and growth, but peripheral bronchi remain hard to segment, particularly in children, whose airways are smaller and for whom few annotated scans exist. Different models recover complementary branches of the airway tree. Their union improves overall tree coverage but also introduces disconnected non-airway objects. We propose anchored fusion (A-Fuse), which takes the voxel-wise union of TfeNet, a retrained MEDPSeg and a reimplemented AirMorph and retains the connected component with greatest overlap with the AirMorph mask. On 30 held-out adult CTs from the ATM'26 training set, A-Fuse reaches a Dice score of 93.24% and the highest branch detection rate among compared methods (92.05%). On nine pediatric scans, it reaches 94.15% Dice and 68.79% branch detection. A-Fuse retains the airway tree in all 39 test scans, whereas keeping the largest component selects a non-airway object in four. A-Fuse is deployed as an automated web application and we release all code, trained weights and an open-source ITK-SNAP extension for 3D tubular segmentation editing.

0.41

Airway cross-sectional area measurement using quantitative endoscopy with AI-enabled depth estimation: A proof-of-concept study

eess.IV ·2026-09-25 ·Amirsajjad Taleban, Jake Luo, Christopher E. Larkee, B. Tucker Woodson, Ryan Puccia +2 more
similarity 0.56
Abstract · 37 pages, 12 figures

Endoscopy is widely used in medicine to visualize anatomical structures for diagnosis and treatment evaluation. However, it does not currently allow rapid, quantitative measurement of airway cross-sectional area (CSA), a key metric for diagnosing and managing respiratory pathologies. There is growing interest in AI-enabled quantitative endoscopy using depth estimation, but a fundamental challenge is the need for ground-truth depth data to train algorithms capable of quantifying depth in physical units (e.g., meters). In this study, 60,000 paired virtual endoscopy images and depth maps were created in Blender from 3D airway models built from computed tomography. A U-Net convolutional neural network was trained to predict the depth maps from the endoscopy images. Point clouds were reconstructed from the AI-generated depth maps using the Equisolid fisheye lens model, and airway perimeters were identified by intersecting a plane with the point cloud to estimate CSA. Nasopharyngeal CSA, a key metric in obstructive sleep apnea, was quantified using this AI-enabled approach with a median error of 5.3 \% relative to the 3D model ground-truth. This pilot study using synthetic data provides strong evidence for the feasibility of developing AI-enabled quantitative endoscopy for airway CSA measurement.

0.35

Dense Endoluminal Mapping and Localisation from Monocular Bronchoscopy

cs.CV ·2026-10-12 ·Salvatore Esposito, Matias Mattamala, Daniel Rebain, Liang Zhao, Kev Dhaliwal +2 more
similarity 0.55
Abstract

Bronchoscopy inserts a camera through the airways to diagnose endoluminal disease. Locating the camera along the airway usually requires additional equipment, such as an electromagnetic tracker and a preoperative CT scan. In this paper, we investigate the use of the monocular camera stream to localise the bronchoscope without requiring additional sensing. We introduce a monocular SLAM system that localises the tip of a bronchoscope and reconstructs the airway surface around it from RGB video alone. A Depth Anything 3 backbone, fine-tuned on over a million photorealistic airway renderings, returns metric per-pixel depth and is the system's only source of scale. DINOv3 features routed through a custom cross-attention matcher supply sub-pixel correspondences on mucosa where classical descriptors fail. Both enter a factor graph alongside a dense constraint from projective iterative closest point (ICP) registration against the system's own running reconstruction, so surface evidence stabilises the directions the visual factors leave weakly observable. On six airways rendered from patient CT scans, the system reaches 26.1 mm mean absolute trajectory error and 77.5% mean surface F-score. Its mean surface accuracy exceeds that of five recent monocular SLAM and feed-forward baselines. MASt3R-SLAM, which fits a free scale to the ground truth, has a lower mean trajectory error (22.0 mm). ORB-SLAM3 completes only two of the six airways, whereas our system completes all six and also reconstructs two ex vivo specimens.

0.16

BronchoTop: Bronchoscopy Navigation via RGB-Only Topological Localization

cs.CV ·2026-09-23 ·Clara Tomasini, Ana Cristina Murillo, Luis Riazuelo
unusual similarity 0.54
Abstract

Accurate localization of the bronchoscope within the bronchial tree is essential for clinicians to be able to reach target lesions, perform biopsies and avoid misidentification of airway segments during diagnostic and therapeutic procedures. However, existing navigation systems typically rely on patient-specific CT scans or additional external sensors, increasing cost, setup time and patient radiation exposure. This work presents BronchoTop, a real-time, RGB-only framework for topological bronchoscopy localization that eliminates the need for patient-specific data. BronchoTop estimates scope location relative to a generic airway model through four modules: lumen detection and tracking, lumen-branch label association, probabilistic scope location estimation, and switch verification. By using only standard bronchoscopy video input, BronchoTop provides practical, real-time navigational assistance to physicians. Evaluation on phantom, simulated and real data demonstrates state-of-the-art accuracy, improving existing approaches performance by over 20% on real bronchoscopy sequences. BronchoTop is the first published framework including both the localization algorithms as well as all the real data used, together with code to generate additional simulations, encouraging and facilitating further developments and benchmarking. The results highlight BronchoTop's potential to enhance procedural safety, efficiency and accessibility in clinical and robotic bronchoscopy.

0.32

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.53
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12

An integrated geometric quantification and shape analysis framework for axillary lymph node metastasis in breast cancer patients

cs.CV q-bio.QM ·2026-09-28 ·Zixi Yi, Limeng Qu, Gary P. T. Choi
unusual similarity 0.53
Abstract

Quantitative characterization of lymph node morphology is important for assessing axillary lymph node metastasis in breast cancer. However, surfaces reconstructed from computed tomography (CT) segmentation may contain geometric and topological defects that compromise subsequent analysis, while conventional shape descriptors predominantly characterize global morphology. To address these issues, we developed an integrated framework combining topology-aware surface processing with multi-resolution spherical harmonic (SH) analysis of CT-derived axillary lymph nodes. The processing pipeline produced topology-valid genus-0 surfaces with improved mesh quality, which were then represented at multiple SH degrees and characterized using 20 predefined geometric feature families. Geometric fidelity increased with SH degree, whereas predictive performance peaked at intermediate resolutions. Preferred SH degree also differed across feature families. A family-specific mixed-resolution model achieved an AUC of 0.918, compared with 0.884 for the conventional PyRadiomics Shape14 baseline, corresponding to an improvement of 0.0344. Controlled perturbation experiments showed that higher SH degrees transmitted more fine-scale geometric variation and yielded lower stability of curvature-based predictions. Representative geometric descriptors provided interpretable characterization of metastasis-associated surface morphology. Independent validation further supported the framework's transportability: label-free replication in a multicenter lymph node cohort reproduced the family-specific resolution effects, while a labeled LIDC-IDRI lung-nodule experiment reproduced the resolution-dependent relationship between SH degree and predictive performance. Altogether, the framework provides a topology-valid basis for quantitative characterization of lymph node morphology and metastasis-associated imaging phenotypes.

0.25

LungMend: A Healthy-Only Latent Diffusion Shape Prior for Lung Mask Correction in Severe Tuberculosis CT

cs.CV ·2026-11-04 ·Rezkellah Noureddine Khiat, Pierre-Yves Brillet, Catalin Fetita
code/data similarity 0.53
Abstract · 5 pages (4 + 1 references), 2 figures, 2 tables. Submitted to IEEE ISBI 2027. Code: https://github.com/noureddinekhiati/LungMend

Lung segmentation models such as R231 are widely used, but they fail on severe tuberculosis (TB) CT: cavities and consolidations look like non-lung tissue and are left out of the mask. We present LungMend, a post-processing model that corrects such masks using only healthy anatomy. A latent diffusion model, trained on healthy lungs with synthetically corrupted masks, learns to recover the complete lung from the faulty mask and the bone anatomy, without any pathological data or CT intensities. LungMend recovers cavities and consolidations that R231 misses and improves accuracy on expert-annotated slices. Code: https://github.com/noureddinekhiati/LungMend

0.38

Anatomy-Aware Prediction of Bronchoscopic Accessibility from 3D CT

cs.CV ·2026-09-29 ·Linkai Peng, Cuiling Sun, Bin Wang, Jamie Rowell, Catherine Gao +8 more
top venuebenchmark similarity 0.53
Abstract · Accepted in MICCAI 2026

Pre-operative planning for bronchoscopy is critical for the diagnosis of lung lesions. Current accessibility assessment relies on subjective manual inspection of CT scans, which is time-consuming and prone to inter-observer variability. In this paper, we formalize bronchoscopy accessibility prediction as a novel supervised learning task and present the first end-to-end framework to address it. We propose an Anatomy-Aware Mixture-of-Experts (MoE) model that integrates specialized modules: a CT Expert for local morphological features, a Lobe Expert for anatomical priors, and a Path Geometry Expert that encodes the sequential constraints of the bronchial tree. To support this task, we curated the first clinical dataset of 438 cases with pre-operative CT scans and documented procedural outcomes. Experimental results demonstrate that our method achieves an AUROC of 0.8052, significantly outperforming both state-of-the-art baselines and experienced human experts. This work establishes a new benchmark for computer-aided interventional planning in pulmonary medicine. Our data and code will be publicly available at https://nubagcilab.github.io/BronchoAccess/.

0.37