CS Paper Radar

An integrated geometric quantification and shape analysis framework for axillary lymph node metastasis in breast cancer patients

Zixi Yi, Limeng Qu, Gary P. T. Choi

cs.CV q-bio.QM ·submitted 2026-09-28 15:39 UTC · v1
unusual

Abstract

Quantitative characterization of lymph node morphology is important for assessing axillary lymph node metastasis in breast cancer. However, surfaces reconstructed from computed tomography (CT) segmentation may contain geometric and topological defects that compromise subsequent analysis, while conventional shape descriptors predominantly characterize global morphology. To address these issues, we developed an integrated framework combining topology-aware surface processing with multi-resolution spherical harmonic (SH) analysis of CT-derived axillary lymph nodes. The processing pipeline produced topology-valid genus-0 surfaces with improved mesh quality, which were then represented at multiple SH degrees and characterized using 20 predefined geometric feature families. Geometric fidelity increased with SH degree, whereas predictive performance peaked at intermediate resolutions. Preferred SH degree also differed across feature families. A family-specific mixed-resolution model achieved an AUC of 0.918, compared with 0.884 for the conventional PyRadiomics Shape14 baseline, corresponding to an improvement of 0.0344. Controlled perturbation experiments showed that higher SH degrees transmitted more fine-scale geometric variation and yielded lower stability of curvature-based predictions. Representative geometric descriptors provided interpretable characterization of metastasis-associated surface morphology. Independent validation further supported the framework's transportability: label-free replication in a multicenter lymph node cohort reproduced the family-specific resolution effects, while a labeled LIDC-IDRI lung-nodule experiment reproduced the resolution-dependent relationship between SH degree and predictive performance. Altogether, the framework provides a topology-valid basis for quantitative characterization of lymph node morphology and metastasis-associated imaging phenotypes.

Closest papers

Nearest neighbours by meaning across the whole index.

From Pixel Generation to Topological Inference: Structural Dual Super-Resolution for Trustworthy Cross-Physical-Domain Trabecular Morphology Learning

cs.CV ·2026-09-28 ·Fan Zhang, Yi Zhang, Yuhui Dong, Ling Wang, Xin Xu
similarity 0.54
Abstract · 23 pages,7 figures

Clinical CT and UHRCT cannot resolve individual trabeculae, whereas synchrotron radiation microCT (SRuCT) provides high-resolution references but is not applicable for in vivo imaging. The two domains differ by a 32x resolution gap, are only coarsely paired, and exhibit severe physical differences including partial volume effects, noise, and artifacts. Existing super-resolution networks and pretrained-prior methods (GLEAN/StyleGAN2, Stable SR/LDM) underperform because they target pixel generation---diverse details and SSIM/PSNR---and do not model these physical differences. Pixel generation for a 32x resolution gap is intrinsically ill-posed. We propose a paradigm shift from pixel generation to topological inference: deterministically predicting invariant microstructures from macro-scale low-resolution inputs, evaluated by morphological parameters. The core of our 2D morphology learning lies in training on 2D slices while evaluating on 3D morphological parameters, ensuring that the learned representations capture true three-dimensional trabecular topology rather than 2D pixel statistics. We realize this paradigm via structural dual super-resolution, coupling forward physical degradation (micro-to-macro) with inverse structural inference (macro-to-micro) through structural duality constraints. The method is an end-to-end, few-shot, compact structural dual network (SDN), comprising a bidirectional modeling network, a multi-scale structural consistency discriminator, and four structural duality constraints. On the test set, SDN achieves morphological parameters largely consistent with SRuCT across six metrics, with SSIM reaching 0.8. Trained on 3.2 um SSRF data, the model generalizes well to 3.25 um isotropic BSRF data from an independent source, validating cross-source generalization and confirming trustworthy structural inference rather than pixel generation.

0.19

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.54
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

DC-SQEM: Medial Mesh Extraction by Dual Contouring with Spherical Quadric Error Metric

cs.GR ·2026-11-05 ·Bingchuan Li, Ruilong Liu, Tianhao Hu, Congyi Zhang, Ningna Wang +2 more
similarity 0.54
Abstract

The medial axis, as a compact representation, describes not only the boundary but also the interior of the shape, and has been widely used in analyzing and simplifying shapes. However, approximating feature-preserving medial axis from unstructured data, such as oriented point clouds, remains challenging due to the lack of explicit connectivity and the presence of noise in the source. We propose DC-SQEM, a dual-contouring-based framework that computes medial meshes (an explicit representation of the medial axis) directly from oriented point clouds without relying on watertight manifold surfaces or volumetric structures. With the help of an adaptive octree, our method fits local medial spheres for each cell based on the Spherical Quadric Error Metric (SQEM). We address several long-standing robustness issues in dual-contouring and mesh extraction, including out-of-cell solutions, unstable feature classification, and redundant topological connections. To this end, we introduce virtual nodes, a feature-downgrading strategy, and a geometry-driven topology-aware cleanup procedure, enabling robust SQEM-based medial dual contouring with clean mesh outputs. Unlike prior point-cloud-based methods that produce either only 1D skeletal structures or incomplete medial features, our method preserves sharp geometric features from the input and reconstructs a complete medial structure, including sheets, curves, seams, and junctions. Compared to restricted-power-diagram-based approaches, our algorithm can handle point clouds as input, without having a strong requirement on water-tightness or manifoldness.

0.19

CT-RespGeomLib: Deterministic reconstruction of CT airway masks into editable,port-matched lumen geometry

eess.SY ·2026-11-12 ·Nichula Wasalathilaka, Kevin Dawson, Chinthaka Jacob, Mervyn Parakrama Ekanayake, Roshan Godaliyadda
similarity 0.53
Abstract

Patient-specific airway modelling requires geometrically consistent lumen surfaces with identifiable boundaries and support for controlled anatomical modifications. We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence. The parametric representation further enables localised modelling of airway stenosis and dilation without re-segmentation. Evaluated on 42 reference airway masks from ATM22 (15 cases) and AeroPath (27 cases), the framework produced 37 topologically accepted reconstructions, with a median port-to-loop distance of 0.123 mm across 2174 matched ports. Reconstructed and reference equivalent radii showed strong agreement ($R^2 = 0.976$), with a mean bias of -0.414 mm arising primarily from the circular, inscribed-radius representation. Controlled pathology modelling generated 40 variants across five patient-specific geometries, including 25-75% stenosis and 50% dilation at tracheal and main-bronchus locations. Prescribed radius changes were reproduced with a mean absolute ratio error of 0.0056, while the median 95th-percentile deviation outside the modified region was 0.111 mm. Downstream applicability was demonstrated through volume meshing and an OpenFOAM simulation with individually prescribed model-based resistance conditions at 62 outlets. Although additional surface preparation may be required for numerical meshing, CT-RespGeomLib provides a reproducible framework for CT-derived airway reconstruction, quantitative boundary validation and controlled geometric pathology modelling.

0.23

Clinical Feasibility of Low-Magnification Fluorescence Imaging for Breast Cancer Margin Detection Using Texture Analysis and Deep Learning

cs.CV cs.AIcs.LG ·2026-08-11 ·Pouya Afshin, Tianling Niu, Tongtong Lu, David Helminiak, Julie Jorns +4 more
published similarity 0.51
Abstract · This research has been accepted and published in Journal "Biomedical Optics Express" in July 2026 with Manuscript ID is 596807

High-resolution images of unprocessed surgical breast tissue can be obtained using microscopy with ultraviolet surface excitation (MUSE). This technique is considered a promising method for checking surgical margins during breast cancer surgery. In this study, MUSE images at 4x and 10x magnifications were compared using patch-level classification methods. Texture analysis (TA) based on local binary patterns (LBP) and deep learning (DL) with a base Vision Transformer (ViT) model were used. Both methods achieved similar performance at both magnifications. Using DL method, both 4x and 10x magnifications achieved 96.30% sensitivity, 100% specificity and 98.18% accuracy. Using TA method, 4x achieved better specificity (100% vs 93.33%) and 10x yielded higher sensitivity (100% vs 93.33%), but both had the same accuracy (96.67%). No clear improvement in performance was observed with 10x magnification. These results show that 4x imaging achieves the same diagnostic accuracy as 10x imaging. At the same time, 4x offers a larger field of view and faster image capture. Therefore, lower magnification can be effectively used in MUSE systems for accurate and efficient intraoperative margin assessment.

0.28

Mind the Gap: Mesh-Guided Repair of Broken Vessels

cs.CV ·2026-09-24 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.51
Abstract · Accepted at ShapeMI 2026 (Shape in Medical Imaging), MICCAI 2026 Workshop. 17 pages, 5 figures, 3 tables

Vessel segmentation is commonly optimized as voxel-wise classification, but small local errors can strongly disrupt vascular connectivity while having little effect on overlap scores. This is particularly problematic for downstream analyses that rely on centerlines, branches, connected components, or graph structure. We propose a mesh-guided post-processing framework for repairing broken vessel segmentations produced by nnU-Net. For each predicted binary mask, a deformable template mesh is fitted to the mask surface in physical space and used as a case-specific geometric scaffold. The fitted mesh is not voxelized as the final segmentation; instead, it guides conservative reconnection of disconnected components by proposing or validating thin bridge candidates under foreground-growth constraints. We evaluated this approach in three vascular anatomies using AortaSeg24 and SEGA for the aorta, TopCoW for the Circle of Willis, and PARSE for the pulmonary arteries. Performance is measured using Dice, connected-component Dice (ccDice), and the Betti-0 number. Across these datasets, repair substantially improved connectivity while preserving overlap: Dice remained nearly unchanged, whereas ccDice increased from 0.596 to 0.992 for aorta, from 0.722 to 0.835 for TopCoW, and from 0.028 to 0.862 for PARSE. The FOMAML meta-initialization further accelerated the fitting per-case, supporting practical mesh-based repair of the vascular topology. These results suggest that explicit mesh representations can provide a useful geometric prior for correcting topological failures in otherwise accurate voxel segmentations.

0.33

From Surfaces to Volumes: Registered Geometry for Protein Representation Learning

cs.AI ·2026-09-28 ·Siyuan Chen, Cai Zhou, Jinrui Zhang, Zhaokang Liang, Taku Komura +6 more
similarity 0.51
Abstract

Existing protein geometry models typically represent molecular surfaces using local geometric features such as sampled points, normals, and curvature. While effective for capturing exposed molecular shape, these representations do not explicitly model the volumetric organization beneath the surface or provide a consistent coordinate system for residue-wise volumetric structure. We introduce Protein-TetSphere, a registered residue-wise volumetric representation for proteins. Each protein chain is tetrahedralized to obtain local volumetric regions associated with individual residues, which are then registered to a shared fixed-topology tetrahedral reference and represented in a common Laplacian basis. This registration establishes consistent volumetric coordinates across residues, enabling local three-dimensional deformation to be integrated with surface and chemical information in a multimodal protein representation. We evaluate Protein-TetSphere on ligand-binding pocket classification, protein--protein interface prediction, and de novo protein binder design. Across the three tasks, Protein-TetSphere improves ligand-binding pocket balanced accuracy from $0.795$ to $0.826$, Pinder-Pair/Site AUROC from $0.914/0.852$ to $0.932/0.866$, and binder-design success from $14.95\%$ to $19.90\%$ on the BoltzGen Challenge Set and from $27.62\%$ to $32.19\%$ at the ProtDBench backbone level. These results show that registered volumetric geometry provides complementary spatial information beyond molecular surfaces across protein recognition, interaction, and design.

0.18

AI-based characterization of lymphoid structures and the tumor microenvironment reveals lower mature tertiary lymphoid structures, lymph-node follicles, and plasma cells after neoadjuvant therapy in lung squamous cell carcinoma

cs.CV q-bio.QM ·2026-11-09 ·Arne Schmidt, Justin Nieder, Cornelius Boehm, Julika Ribbat-Idel, Marius Teodorescu +22 more
similarity 0.50
Abstract

Mature, germinal centre-bearing tertiary lymphoid structures (TLS) and mature lymph node follicles (secondary lymphoid structures, SLS) sustain the plasma cell response that shapes outcome and immunotherapy benefit in lung cancer. How this loco-regional axis differs between neoadjuvant-treated and therapy-naive tumors is poorly defined. We analyzed H&E whole-slide images of resected tumors and paired proximal and distal lymph nodes from matched neoadjuvant-treated (neoLUSC, n=20) and therapy-naive (naivLUSC, n=20) lung squamous cell carcinoma (LUSC) patients. Aignostics Atlas H&E Tissue Analysis (HETA) models quantified cell densities per tissue compartment and cell-cell co-localization; a dedicated deep-learning model validated against pathologist annotations detected TLS and SLS and graded their maturity. Prognostic value was tested in an independent cohort (n=458; 46 treated). In neoLUSC tumors, stromal plasma cell density was 72% (p=0.004) and stromal lymphocyte density 48% (p=0.015) lower than in naivLUSC; macrophages and granulocytes did not differ significantly. Total and immature TLS did not differ, whereas mature TLS in the tumor (p=0.034) and mature SLS in the tumor-distal lymph node (p=0.003) were lower in neoLUSC patients. Peri-TLS plasma cell density correlated with tumor lymphocyte density in naivLUSC (rho=0.54, p=0.017) but not in neoLUSC tumors (rho=0.07). In the validation cohort, stromal plasma cell density (HR 0.69, p=0.011) and lymphocyte-plasma cell co-localization (HR 0.66, p=0.004) were associated with longer survival, and neoadjuvant status with shorter survival (HR 1.50, p=0.026). Neoadjuvant therapy is thus associated with fewer mature lymphoid structures and weaker coupling of the humoral compartment to the tumor rather than uniformly lower immune readouts. The stromal plasma cell/co-localization axis is a candidate prognostic biomarker.

0.31