CS Paper Radar

Size-Matched Nulls Reveal What Block Ablation Measures in MambaVision

Tahmina Kousar, Tehseen Zia

cs.CV ·submitted 2026-11-14 08:23 UTC · v1
unusual

Abstract

Hybrid vision backbones interleave Mamba state-space mixers with self-attention, and a block's role is usually probed by removing it and measuring the damage. We test what that measurement means in MambaVision. On all 50,000 ImageNet validation images and three model sizes, every block ablation is paired with a size-matched null, the same perturbation with its channels shuffled or their signs flipped. In top-1 accuracy and in true-class rank, real and null damage are nearly indistinguishable in absolute terms: pooled over the blocks of MambaVision-T, the content effect lies within [-0.044,+0.016] percentage points (90% interval). Two attention-only controls show that the test detects content, with real ablations worse than their nulls by up to 4.2 points in DeiT-Small and 1.0 point in Swin-T. Part of MambaVision's near-equivalence reflects how little damage its blocks do (0.11--0.34 points on average, against 1.7 and 2.1). Scaled by damage, its content share is comparable to Swin-T's in accuracy, lower in rank, and far below DeiT-Small's: single-block damage in MambaVision is small and mostly positional. Ablation also hides what blocks carry together: removing all blocks of one type compounds damage to 3.7--8.4 times the sum of single effects, far more than size-matched nulls, including nulls that keep the alignment between the blocks' perturbations; for adjacent pairs, aligned nulls reproduce most of it. Freezing input-dependent selection in all Mamba mixers shows that it accounts for 20--32% of the Mamba contribution, mainly through the B and C projections. We turn these results into a protocol for causal attribution in hybrid networks.

Comment
15 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Trading Parameters for Accuracy in MambaVision for Chest Radiograph Classification

cs.CV ·2026-11-15 ·Qaiser Farooq, Tehseen Zia
similarity 0.55
Abstract · 10 pages, 4 figures, 9 tables. Submitted to an IEEE journal

MambaVision, a hybrid state-space and attention backbone, places most of its parameters in its widest, fourth stage. We quantified what that stage contributes to multi-label chest radiograph classification. The fourth stage was replaced with lighter single-scan state-space blocks adapted from Spatial-Mamba, with multi-scale dilated depthwise convolutions applied to the scan output; the first three stages were retained. Tiny, Small, and Base models were evaluated across nine dataset-scale combinations drawn from two source cohorts: the National Institutes of Health ChestX-ray14 archive (full ChestMNIST and a high-resolution subset) and Indiana University Open-i. At the Tiny scale, replacement reduced parameter count by 35.7% and increased graphics processing unit throughput by 19.3%; the savings came from the stage's dense projections, not from removing quadratic attention. Without distillation, the mean area under the receiver operating characteristic curve on ChestMNIST was 0.004 lower than the baseline (95% bootstrap confidence interval, 0.002 to 0.006), and 0.003 to 0.006 lower across all nine combinations. Knowledge distillation from an unreplaced teacher narrowed the gap to the undistilled baseline to 0.001-0.002 and met the equivalence criterion on ChestMNIST, but distilling the baseline with the same recipe improved it by 0.001-0.003, so a gap of 0.002-0.005 persisted under symmetric training. At the Base scale, the unreplaced Small model was both smaller and more accurate. Fourth-stage replacement is a useful trade-off only for Tiny and Small models. These measurements let developers of chest radiograph screening tools weigh model size and speed against a quantified loss of diagnostic discrimination.

0.30

Output-Aware Block Influence: Jacobian-Lens Weighting for Depth Pruning

cs.LG cs.AI ·2026-09-30 ·Kyle Lemoi, Jonathan Yong, Shubhankar Tripathy, Priestley Fernandes, Anirban Majumder +1 more
published similarity 0.53
Abstract · 11 pages, 7 figures, NeurIPS 2026 AXIOM Workshop

Depth pruning removes entire transformer blocks and therefore depends on a reliable criterion for identifying which blocks can be removed. Block Influence (BI) ranks blocks by how minimally they rotate the hidden state. However, local redundancy does not necessarily imply downstream irrelevance. We address this limitation using the Jacobian Lens (J-Lens) neural artifact, a map transporting perturbations at a layer to the final residual stream. At a common sparsity level, pruning scores applying J-Lens transportation to $BI$, what we call $J-BI$, were found to improve post-pruning accuracy by up to 19 points over $BI$ while reducing damage to perplexity for Qwen3-8B, Llama-3.1-8B-IT, and Gemma-3-12B-IT. We also perform a single-block ablation study and use J-Lens probing to explain why the proposed scores improved performance.

0.36

ModaLens: Measuring Image Sensitivity in Report-Conditioned Medical VLMs

cs.CV cs.AI ·2026-09-14 ·Sebastián Andrés Cajas Ordóñez, Maximin Lange, Quang Bui, Anqi Peter Li, Felipe Ocampo Osorio +7 more
code/data similarity 0.52
Abstract

A radiology report can already answer a clinical question, so it is hard to tell whether a vision-language model also uses the image. ModaLens, a paired image-swap audit, measures how report availability changes image sensitivity: MedGemma-27B on 3,199 paired MIMIC-CXR cases from 293 patients, all 14 questions per case (13 finding-specific and one composite), each image replaced by one from another study, usually of the same patient, with question and report fixed. Under an explicit answer instruction, the model's generated answer changes on 4.26 percent of trials with the report and 20.94 percent without it, a paired increase of 16.7 points (patient-clustered 95 percent CI 15.6 to 17.7), so report availability reduces image-swap sensitivity under this protocol; the original prompt with a lowercase first-token readout gives 4.70 percent against 17.07 percent, and substitutions also move continuous answer scores where the binary prediction does not change. The labels are derived from reports, which limits conclusions about visual correctness; the direction replicates in two further model lineages. Code, the exact prompts and a run record for every number are at https://github.com/criticaldata/MODALENS.

0.67

Beyond Mean Foils: Auditing Worst-Foil Specificity in Frozen CLIP Region Explanations

cs.CV ·2026-09-23 ·Kaixin Liu, Zhipeng Ye, Feng Jiang, Zhenghao Wang, Qihang Wu
similarity 0.51
Abstract · 5 pages, 2 figures, 6 tables

A region can overlap a target object yet contribute more to another class. We test regions selected by Cluster-based Concept Importance (CCI) in frozen CLIP. Across COCO and VOC with two checkpoints, 41.08-64.78% of regions that pass overlap and mean-contrast checks fail against the strongest competing class. Removing competitors annotated in the image leaves 39.69-63.64% failing. We then test all eight candidate regions per image. An alternative passes the test for 6.25-7.84% of failures on COCO and 27.40-31.15% on VOC. Requiring it to preserve the original target-score drop within $ε= 0.02$ reduces these rates to 0.16-0.98%. Available regions and target-drop tolerance constrain repair; relaxing the tolerance increases repair opportunities.

0.27

Physics-Shaped, Not Physical: Auditing Physics-Guided Underwater Image Restoration

cs.CV ·2026-10-14 ·Mochamad Rizal Fauzan, Irgi Surya
similarity 0.50
Abstract · 17 pages, 7 figures, 4 tables

Physics-guided networks for underwater image restoration predict transmission and backscatter and invert the image-formation model, yet rarely test whether this physics does any work. We audit one representative design, PhysGuide-Net, with four controlled experiments: five-seed ablations on UIEB with zero-shot evaluation on the complete LSUI (4279 pairs) and AUIED3K (3000 pairs) sets; a data-efficiency study with a capacity-matched control that removes the formation model; and a validation of the predicted maps against measured range on Sea-thru. With all 800 training images the physics module gives no zero-shot gain (mean PSNR differences of at most 0.16 dB; all 95% intervals include zero) at 3.4x the FLOPs. With 80 images it helps more (+0.65 dB on UIEB, +1.48 dB on AUIED3K; seed-to-seed s.d. on AUIED3K from 1.3 to 0.5 dB), although not individually significant after correction, and the control does not reproduce this (0.8-1.0 dB lower). Yet the predicted transmission does not behave like a physical quantity: its correlation with range is no stronger than for the range map of a different image (pooled difference +0.02, versus -0.06 for the dark-channel prior), and a Beer-Lambert fit explains 0.4% of its variance. The effect of the module also changes sign with degradation severity between datasets. The benefit thus comes from a physics-shaped inductive bias, not from physics. We further show that single-run ablations can reverse sign and document implementation defects that invalidate loss ablations.

0.25

CALIPER: Clean Scenes Cannot Rank Physical Inference in Pretrained Visual Representations

cs.RO cs.AIcs.CV ·2026-09-08 ·Aman Mehta, Riya Baviskar
benchmark similarity 0.50
Abstract

How far a pushed object slides depends on its mass and friction, which no single image reveals. Pretrained visual encoders are increasingly used as the perception front end of world models for manipulation, and their physical competence is assessed with perturbation benchmarks and linear probes, almost always in a clean, fixed-camera scene. We show that these assessments cannot distinguish an encoder that infers physics from one that does not. CALIPER (calibrate, then predict) is a direct test: an object of unknown mass and friction is struck twice at known speeds, a third strike is shown only up to the moment of contact, and a linear readout on frozen features must predict how far the object slides. Swapping in another object's calibration clips checks that the evidence is actually used. Across 2,000 simulated episodes and eight representations, from V-JEPA 2 to a randomly initialised ViT and raw pixels, calibration adds +0.50 R^2 and the swap removes it. Yet in the clean scene every representation lands within 0.02 R^2 of the ceiling set by true simulator state, because a fixed camera exposes the object's displacement directly in pixel coordinates. Resampling camera, lighting, and clutter for every clip spreads the same representations across 0.50 R^2; when the readout chooses a push speed for a goal distance, V-JEPA 2 misses by 4 mm and the random ViT by 20 mm, no better than ignoring the object. Linear probes track none of this: a change in frame aggregation moves a probe more than pretraining does, and erasing the probed mass direction from the same representation costs nothing in one scene and 0.35 R^2 in the other. Whether a benchmark can rank models is an empirical property, and we give three checks that establish it.

0.40

Do Saliency Maps Fail Dense Breasts? A Chance-Normalized, Confounder-Aware Audit of Explanation Fairness in Mammography

cs.CV cs.AI ·2026-11-04 ·Ahmed Jaheen
similarity 0.50
Abstract

Saliency maps, offered as evidence that mammography classifiers use the cancer, are untested in dense breasts, which can hide cancers. We tested whether they locate cancers worse there, and why. On 1,345 malignant CBIS-DDSM views, we scored three CNNs' Grad-CAM, Integrated Gradients and occlusion maps by whether their peak hits the lesion and a chance-normalized lesion-to-background saliency ratio (bits; +1 doubles it). Unadjusted gaps were large: Grad-CAM peaks hit 44% of dense vs. 58% of non-dense lesions. Case mix, chiefly more calcifications in dense breasts, explained about half or more of each gap. Occlusion kept a significant average of -0.56 bit gap. Controls also implicate the classifiers: unadjusted gaps exceeded an image-only conspicuity map's, and models relied less on dense-breast lesions. We recommend reporting density gaps before and after case-mix adjustment, per classifier, with conspicuity and lesion-reliance controls.

0.28

Does Video Memory Use What It Retrieves? A Causal Audit of Memory Specificity

cs.CV ·2026-09-10 ·Aditi Tiwari, Akshit Bhalla, Darshan Prasad, Heng Ji
similarity 0.50
Abstract · 18 pages, 9 figures, 15 tables

Video models increasingly use memory to preserve information over long sequences, with the assumption that gains come from retrieving and using the correct past content. Standard memory ablations test whether memory helps, but not whether the retrieved content is responsible. We test this directly with read-time memory substitution, which replaces the consumed memory value while leaving the rest of the computation unchanged. This separates memory benefit from memory specificity, the extent to which the gain depends on retrieved content. Across frozen video world models, identity-free controls containing no evaluation-specific content recover essentially the full benefit on Ego-Exo4D and 7-Scenes and about 70% on TUM. In the Ego-Exo4D dose response, recovery falls from 102% to 1% as these values move away from observed training-memory representations, supporting representation repair as the best-supported explanation in this setting. WorldMem shows graded dependence. A wrong memory from the same trajectory recovers 94.1% of the PSNR benefit relative to zero content, while a donor from a disjoint trajectory and biome recovers 43.7%. SAM 2 shows strong content dependence. On DAVIS, replacing the correct spatial memory with a valid wrong memory reduces mean region and boundary score from 0.926 to 0.182. At MOSEv2 reappearance, it falls from 0.459 to 0.000. These results show that memory gains can depend on generic representation support, broader context, or exact episodic content. Read-time substitution provides a direct way to distinguish them.

0.48