Where slide-level foundation-model classifiers fail on atypical breast lesions

Nerea Hernandez, Luis J. Herrera, Cesar Ramirez, Olga Valenzuela, Ignacio Rojas, Francisco M. Ortuño

cs.CV cs.AI ·submitted 2026-11-14 21:29 UTC · v1
unusual

Abstract

Whether a ductal breast lesion is called atypical hyperplasia or low-grade carcinoma in situ increasingly determines surgery. However, slide-level classifiers built on pathology foundation models (PFMs) perform worst on these lesions. Using four PFMs, cross-validation on BRACS and preregistered hypotheses, we studied where the classification of atypia fails. Because slides are labelled with their most severe lesion, only 39% of the slides with annotated atypical ductal hyperplasia (ADH) were labelled ADH. Attention ranked the lesion high but rarely first, and showing the model only the lesion helped little, whereas classifiers trained per decision with lesion-level labels improved all four atypical boundaries. ADH regions inserted into benign slides raised the probability of malignancy more than that of atypia. In a hospital with pathologist-labelled single-subtype slides and in HISTAI, benign slides were scored closer to lesions and triage specificity fell from 0.48-0.53 to 0.00-0.07 and 0.22.

Closest papers

Nearest neighbours by meaning across the whole index.

ProtoPur: Prototype-Purity Pseudo-Labeling for Weakly Supervised Instance Learning in Pathology

cs.CV cs.LG ·2026-10-11 ·Chen Shu, Chengyang Zhang, Boyu Fu, Ting Yin, Wenchuan Zhang +3 more
published similarity 0.58
Abstract · Accepted to IEEE BIBM 2026

Weak bag-level labels are widely available in computational pathology, whereas reliable instance-level annotations for whole-slide images remain expensive and ambiguous. Weakly supervised multiple instance learning (MIL) achieves strong bag-level classification, but instance-level supervision from attention scores, model predictions, negative bags, or spatial refinement may fail to identify class-specific local evidence. We propose ProtoPur, a prototype-purity pseudo-labeling method for weakly supervised instance-level learning in pathology whole-slide images. ProtoPur estimates class-balanced local purity over prototype regions constructed from frozen foundation-model features, and assigns pseudo-labels to high-purity regions strongly associated with a target class. This purity-first design separates class-specific evidence from negative or shared morphology, with coverage used only to ensure sufficient pseudo-label assignment. We provide a PAC-style analysis showing that the risk of an instance classifier trained with ProtoPur pseudo-labels can be decomposed into a standard uniform-convergence term and a ProtoPur-specific pseudo-label noise term, comprising selected-region mismatch and a coverage residual. Experiments on three public whole-slide image datasets with two pathology foundation encoders show that ProtoPur consistently improves instance-level performance across multiple MIL backbones while maintaining competitive bag-level performance. Pseudo-label quality comparisons on two public datasets further demonstrate that prototype-purity selection provides stronger instance supervision. These results suggest that the foundation-model features contain exploitable instance-level supervision signals, and ProtoPur is a way to reveal and use these signals from weak bag labels without requiring dense instance annotations.

0.21

Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets

eess.IV cs.CV ·2026-10-09 ·Tran Cao Minh, Hai Tran, Ha Minh Tan
similarity 0.58
Abstract

Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.

0.51

Do Saliency Maps Fail Dense Breasts? A Chance-Normalized, Confounder-Aware Audit of Explanation Fairness in Mammography

cs.CV cs.AI ·2026-11-04 ·Ahmed Jaheen
similarity 0.57
Abstract

Saliency maps, offered as evidence that mammography classifiers use the cancer, are untested in dense breasts, which can hide cancers. We tested whether they locate cancers worse there, and why. On 1,345 malignant CBIS-DDSM views, we scored three CNNs' Grad-CAM, Integrated Gradients and occlusion maps by whether their peak hits the lesion and a chance-normalized lesion-to-background saliency ratio (bits; +1 doubles it). Unadjusted gaps were large: Grad-CAM peaks hit 44% of dense vs. 58% of non-dense lesions. Case mix, chiefly more calcifications in dense breasts, explained about half or more of each gap. Occlusion kept a significant average of -0.56 bit gap. Controls also implicate the classifiers: unadjusted gaps exceeded an image-only conspicuity map's, and models relied less on dense-breast lesions. We recommend reporting density gaps before and after case-mix adjustment, per classifier, with conspicuity and lesion-reliance controls.

0.28

Morphology signal in whole slide image foundation models can automatically triage slides

cs.CV cs.LG ·2026-09-02 ·Ayushi Sinha, Shashank Yadav, Benjamin Holmes, Pravat Das, Aaron W. Bogan +7 more
benchmark similarity 0.57
Abstract · 12 pages, 3 figures, 4 tables

Patient exams in the cancer diagnosis and staging process typically generate several whole slide images (WSIs). One of the initial steps in training models on WSI data is identifying one or a few slides containing tumor or other diagnostic biomarkers necessary for downstream prediction tasks such as estimating recurrence risk or progression-free survival. This step requires tedious manual curation by experienced pathologists. Many published datasets make the artificial assumption of 1 slide per patient. Alternatively, all slides per patient may be used for model training, which may dilute the signal from the few slides containing tumor or other relevant information. In this paper, we present a pipeline to overcome these challenges using publicly available WSI foundation models (FMs). Our evaluations show that ranking WSIs based on predictions from zero-shot classification using WSI FMs accurately identifies slides with the most tumor, indicating that WSI FMs contain sufficient morphology signal to automatically triage slides. We also present a formulation for ranked evaluation to benchmark FM performance in slide triage. We show, on multiple datasets, that tumor slides are identified in the top-2 ranked slides for patients with up to 43 slides.

0.14

Multi-institutional grading of Barrett's esophagus dysplasia without stain normalization using a pathology foundation model and multiple instance learning

cs.CV cs.AI ·2026-11-19 ·Amirali Khosravi, Jaidip M. Jagtap, D. Chamil Codipilly, Catherine E. Hagen, Jason T. Lewis +9 more
similarity 0.56
Abstract

Barrett's esophagus dysplasia grading suffers substantial inter-observer variability, particularly for low-grade dysplasia, complicating clinical decision-making. We conducted a retrospective multi-institutional diagnostic accuracy study of a foundation model-based deep learning system for dysplasia grading, using 969 H\&E-stained whole slide images from four institutions. Patch-level classifiers trained on expert annotations identified diagnostically relevant regions, followed by attribute-aware multiple instance learning for slide-level classification as non-dysplastic Barrett's esophagus (NDBE), low-grade dysplasia, or high-grade dysplasia. On a held-out test set (n = 130), macro-averaged AUC was 0.96 (95\% CI 0.93--0.98). For binary dysplasia detection, sensitivity was 98\% (80/82) and specificity 81\% (39/48), with a negative likelihood ratio of 0.030 and quadratic-weighted \kap{} of 0.83 against expert consensus. No high-grade dysplasia case was misclassified as NDBE. Performance was consistent across institutions without stain normalization, indicating that stain-robust foundation-model representations may remove the site-specific preprocessing that has constrained prior systems to institution-specific deployment.

0.21

With foundation-model features, aggregator complexity does not improve cross-hospital discrimination in gastric whole-slide image classification

eess.IV cs.AIcs.CV ·2026-10-30 ·Nheng Vanchhay, Ali Hussain, Khan Ziaullah, Moon-Il Joo, Md Ariful Islam Mozumder +12 more
similarity 0.55
Abstract

Whole-slide image classifiers are usually developed within one hospital and often go untested at unseen hospitals. We assembled 5,036 haematoxylin-and-eosin-stained gastric slides from five Korean hospitals, scanned at 20x and 40x, and compared multiple-instance learning aggregators under leave-one-hospital-out validation on frozen pathology foundation-model features. A hierarchical patch-region-slide graph aggregator (CHIME-MIL) with site alignment and two-scale fusion reached a mean area under the receiver operating characteristic curve (AUC) of 0.837, above six conventional attention and transformer aggregators trained without these steps. Under a matched recipe it did not exceed attention-based pooling, and global max pooling given the same alignment and fusion was better (AUC 0.855, P = 0.0002). The alignment, which subtracts each hospital's mean feature vector without labels, onboarded a new hospital from ten unlabelled slides and cost 0.002 AUC without held-out-hospital data, but its accuracy gains were small and inconsistent. The model had low top-label calibration error (0.053) but under-confident malignancy probabilities, and removing its most-attended patches lowered the malignancy probability far more than removing random patches. With these features, more complex aggregators did not improve discrimination; what a deployable system adds is label-free onboarding, calibration checks and auditable evidence.

0.13

How Well Do Generalist CT Foundation Models Differentiate Liver Tumors?

cs.CV cs.AI ·2026-11-18 ·Yosuke Yamagishi, Tomohiro Kikuchi, Shouhei Hanaoka, Takeharu Yoshikawa, Osamu Abe
code/data similarity 0.55
Abstract · 12 pages, 3 figures. Code: https://github.com/yamagishi0824/liver-tumor-ddx-ct-fm

Generalist CT foundation models detect many findings with high performance, but their ability to differentiate detected lesions remains largely unevaluated. This retrospective study evaluated two generalist models, RADAR and Merlin, for differentiating liver tumors using a public single-institution multiphase CT dataset (517 cases: hepatocellular carcinoma, intrahepatic cholangiocarcinoma, breast and colorectal cancer liver metastases, and hemangioma). The models were evaluated in a zero-shot setting using their existing outputs and with linear probing, in which only a linear classifier was trained on frozen image features (stratified fivefold cross-validation repeated five times). In the zero-shot setting, RADAR achieved an accuracy of 54.4% (95% CI: 49.9, 58.8) and a $κ$ of 0.37 for four-class differentiation at the portal venous phase and predicted 31% (129 of 421) of malignant tumors as hemangioma. With linear probing of four-phase features, its accuracy improved to 79.9% (95% CI: 76.6, 83.4) with a $κ$ of 0.72, and 1% (five of 421) of malignant tumors were predicted as hemangioma; Merlin achieved an accuracy of 60.9% (95% CI: 56.9, 65.0). Generalist CT foundation models showed limited zero-shot ability to differentiate liver tumors, which improved substantially with linear probing alone.

0.50

TRUST: Threshold-Recalibrated Uncertainty-Safe Training for Certified Dismissal in Breast Cancer Screening

cs.CV cs.LG ·2026-08-31 ·Parham Hajishafiezahramini, Matthew Hamilton, Edward Kendall, Gregory Doyle, Oscar Meruvia Pastor
theory similarity 0.55
Abstract

Reducing the review of clearly cancer-negative screening mammograms could lower radiologist workload without compromising cancer detection. We propose a closed-loop threshold-aware training strategy in which the dismissal threshold is recalculated during training and used to penalize cancer-positive images that approach the dismissal region. We evaluated the method on NLBS and RSNA using five controlled training configurations, with case-level assessment based on a one-sided 99\% Clopper--Pearson upper bound for cancer prevalence among dismissed cases. The proposed model achieved the highest case-level dismissal rates at both 98\% and 95\% recall targets. On NLBS, dismissal reached 19.74\% and 21.70\%, while the cross-entropy baseline did not meet either recall target. On RSNA, dismissal improved from 7.04\% to 14.31\% and from 13.49\% to 19.69\%. In external RSNA$\to$NLBS evaluation, the proposed model achieved dismissal rates of 12.95\% and 19.87\% at the 98\% and 95\% recall targets, respectively. These results support closed-loop threshold-aware training for high-recall selective dismissal.

0.26