CS Paper Radar

Cross-Subject Priors for Maximum a Posteriori Estimation of Latent Structure Influence Models in Motor-Imagery EEG With Few Trials

Sagnik De, Anil Kumar Gupta

eess.SP cs.LG ·submitted 2026-11-15 18:07 UTC · v1

Abstract

Coupled hidden Markov models such as the latent structure influence model (LSIM) describe how the sensorimotor rhythms of the two hemispheres evolve and interact during motor imagery, but subject-specific maximum likelihood (ML) estimates are unstable when few trials are available. This paper derives a maximum a posteriori (MAP) estimator for the LSIM whose conjugate prior equals the expected statistics of $λ$ pseudo-trials from a population model fitted to other subjects. The M-step remains in closed form, expectation maximization keeps its monotone ascent, and ML ($λ=0$) and the population model ($λ\to\infty$) are limiting cases. The prior strength was selected on 35 subjects of the PhysioNet EEG Motor Movement/Imagery Dataset and applied unchanged to 70 held-out subjects and to BCI Competition IV-2a. With $λ=1$ the held-out log-likelihood exceeded that of ML in 61 of 70 subjects (Holm-adjusted $p=9.1\times10^{-8}$) and in all 70 subjects with five training trials per class. A prior learned only from the PhysioNet data improved the held-out likelihood of all nine BCI IV-2a subjects at five trials per class and reduced the error of the joint transition matrix by 61%. Decoding accuracy did not improve ($p=0.17$). Cross-subject priors therefore stabilize few-trial dynamic models of motor-imagery EEG, but they do not improve decoding, which in these data relies mainly on structure shared across subjects.

Comment
9 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.56
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

GRAFT-EEG: Gauge-Aware Physical Field Transport for Cross-Dataset Motor-Imagery EEG

cs.LG eess.SP ·2026-10-16 ·Ying Zhou, Mengting Liu
similarity 0.55
Abstract · Under review at ICLR 2027

Cross-dataset EEG decoding often treats montage, reference, and active-sensor changes as representation shift, although they also alter the observation operator. We study target-statistics-blind transfer: fitting receives no target signal, label, or empirical statistic, and electrode coordinates only instantiate a fixed prediction operator. method removes the active-set common-reference gauge and transports each native mask through a template motor leadfield. A source-fitted spectral classifier anchors the decision; a bounded state-space-model (SSM) residual is secondary. We establish restricted identifiability and an operator-perturbation bound. Across five leave-one-dataset-out targets (253 participants), dynamic method achieved 60.865% equal-target balanced accuracy versus 52.684% for strict-clean 5/5 BIOT (hierarchical difference +8.182 points; 95% CI +6.382 to +10.196; positive in every target). On four EEGPT-clean targets, the descriptive means were 61.520% and 59.057%. In four post-hoc exact same-parent tests, FULL exceeded coordinate-basis, matched-spectrum, row-shuffled, and wrong-anatomy controls by 9.959, 9.698, 11.241, and 3.985 points, respectively (all 95% CIs excluded zero; Holm-adjusted P<0.001). A separate 60-participant same-paradigm evaluation retained a positive physical-operator contrast (+4.029 points; +2.338 to +5.773), whereas dynamic--static was inconclusive; its preregistered status is partial confirmation rather than unrestricted external validation. The SSM added +1.059 points (+0.013 to +1.892). Claims remain bounded to five binary motor-imagery domains and the tested operators.

0.14

Exact Spectral Uncertainty Decomposition for Linear-Gaussian Bayesian M/EEG Inverse Problems

cs.LG cs.CE ·2026-10-21 ·Ismail Huseynov, Stefan Haufe
similarity 0.54
Abstract

Distributed magneto- and electroencephalographic (M/EEG) source reconstruction is a severely underdetermined linear inverse problem. Bayesian source imaging regularizes inversion through source-prior and sensor-noise covariances, but the posterior covariance does not directly distinguish uncertainty constrained by the measurements from uncertainty unobservable under the sensing geometry. We study this distinction for linear-Gaussian M/EEG models with diagonal source-prior and sensor-noise covariances, covering Type-I inference and Type-II inference conditional on learned covariance hyperparameters. After restricting the analysis to the prior-supported source space, standardizing the prior, and whitening the sensor noise, the complete singular spectrum of the forward operator separates likelihood-visible and likelihood-null directions. This yields an additive uncertainty decomposition of the conditional posterior covariance: uncertainty in likelihood-visible directions is reduced according to spectral information content, whereas likelihood-null uncertainty remains unchanged from the prior. The spectral representation also yields a prior-minus-reduction identity, showing that covariance reduction is confined to the likelihood-visible subspace. Spectral markers quantify likelihood information and prior-variance retention and reduction. Fixed-orientation MEG simulations with adaptive noise learning illustrate the framework. Dense Bayesian minimum-norm inference retains a large likelihood-null component, whereas sparse $γ$-MAP strongly reduces the fitted prior support. Within that support, the markers distinguish strongly informed directions from a weakly constrained direction. Thus, prior-support selection determines which source coordinates remain in the fitted model, while the spectral decomposition quantifies how strongly the retained directions are constrained by the measurements.

0.32

Riemannian Suppression of Cross-Session Identity Leakage in Motor-Imagery EEG

cs.CR ·2026-10-11 ·Sheikh Samit Muhaimin, Aarthy Nagarajan
similarity 0.54
Abstract · 23 pages, 5 figures

Electroencephalography (EEG) recorded for motor-imagery (MI) brain-computer interfaces (BCIs) carries subject-identifying structure that persists across sessions, allowing separately released sessions from the same person to be linked. Existing EEG identity protections use learned or additive perturbations and operate on representations other than the covariance geometry underlying MI pipelines. We ask whether cross-session identity leakage can be suppressed directly in this covariance representation without learning a privacy model. We introduce a Riemannian transform that equalizes two subject-conditioned geometric statistics: the Riemannian mean covariance and the tangent-space scatter around it, with two optional band-specific refinements. Ablations show that mean alignment and scatter whitening carry nearly all of the suppression, while the optional stages contribute small, dataset-dependent refinements. Across two public datasets and five attackers spanning four covariance-space representations, the worst attacker falls from 90.8% to 15.6% on BCI Competition IV-2a and from 90.8% to 9.9% on OpenBMI, at a cost of 7.0 and 2.1 points of MI decoding accuracy relative to the 8-30 Hz input, and no aggregation rule exceeds chance by more than two points at any batch size. The transform requires no learned privacy model, surrogate network, or gradient-based training, and is fitted on one session and applied unchanged to a held-out later session.

0.35

NeuroDyn-EEG: An Interpretable Pre-trained Model for EEG Based on Neural Dynamics

cs.NE ·2026-09-29 ·Yi Cui, Tong Zhao, Jiaxin Lei, Chuyi Yang, Yifan Cui +3 more
code/data similarity 0.53
Abstract · Yi Cui and Tong Zhao contributed equally. Corresponding authors: Ling Zhang, Yuxiang Yan, and Bo Hong

Clinical scalp electroencephalography (EEG) offers a noninvasive window into neural dynamics of neuropsychiatric disorders. However, discriminative deep models often lack anatomically indexed physiological interpretability. We propose NeuroDyn-EEG, a pretraining framework integrating generative priors from neural dynamics. It couples an extended Jansen-Rit neural mass model, leadfield-based source projection, and simulation-based parameter inversion. Trained on synthetic parameter-EEG pairs within physiological ranges, NeuroDyn-EEG estimates 11 regional parameter families across 90 AAL regions plus one global parameter from standard 19-channel EEG, using only ~2.43M trainable parameters. We evaluate the framework across three levels. First, controlled simulations demonstrate robust parameter recovery under diverse noise conditions, while real resting-state EEG evaluations confirm spectral and phase consistency in an inverse-forward closed loop. Second, on four clinical benchmarks (AD65, PD31, Figshare MDD, and TUAB), NeuroDyn-EEG achieves competitive classification performance, securing the highest BACC, AUROC, and AUCPR on PD31 and MDD, and highest BACC on AD65. Third, post hoc regional analyses reveal disease-specific alterations: local synaptic connectivity C_1 involves the most altered regions in AD65, whereas the firing threshold theta ranks first in MDD, offering testable mechanistic hypotheses. Overall, NeuroDyn-EEG maps scalp EEG to anatomically indexed dynamical parameters, bridging representation learning and mechanistic neurophysiology. Code: https://github.com/Gnosis-Neurodynamics/NeuroDyn-EEG.

0.21

NOMAD-EEG: Native Omni-Montage Adaptive Diffusion

cs.LG eess.SP ·2026-10-26 ·Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas
similarity 0.53
Abstract · 37 pages and 7 figures

Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We aimed to build a generative EEG foundation model independent of the number, identity and order of electrodes and of the input length. Methods. NOMAD-EEG is a 12.0 M-parameter diffusion model that alternates state-space layers along time, without patches, with attention across electrodes identified only by their 3D scalp position. It was pre-trained on 147 h of unlabelled EEG from a single corpus and evaluated with frozen linear probes on ten datasets with 1 to 64 electrodes against seven foundation models run under one protocol, and on two unseen populations. Results. Despite its small size (12.0 M parameters against 69 M for REVE) and single pre- training corpus, NOMAD-EEG outperformed all seven foundation models on EEGMMIDB mo- tor imagery (balanced accuracy 0.442), Siena seizure detection (macro F1 0.622) and Bonn seizure detection (AUROC 0.999), had the highest accuracy of the seven compared models on TUEP epilepsy diagnosis (0.640) and, after fine-tuning, the highest \k{appa} (0.635) and weighted F1 (0.814) on TUEV event classification. It was the best of five models on P300 detection in autism with an unseen eight-electrode montage (AUROC 0.718). With only 5 of 19 electrodes, its mean AUROC fell only from 0.942 to 0.891. Conclusion. Identifying electrodes by position and modelling time without patches let one small model, pre-trained on one corpus, outperform much larger EEG foundation models on seizure detection, epileptiform event classification, epilepsy diagnosis and motor imagery.

0.14

EEG-AS: Instance-Level Foundation Model Selection for EEG Foundation Models via Behavior Reconstruction

cs.LG cs.AI ·2026-09-01 ·Yunzhen Zhang, Ruoxi Piao, Muhammad Ibrahim Ali Shah, Hasan Onur Keles, Mustafa Misir
theory similarity 0.53
Abstract

Electroencephalography (EEG) is a non-invasive technique for measuring neural activity and has been widely used in neuroscience applications. Recent advances in EEG foundation models have enabled strong performance across diverse neural decoding tasks. However, no single foundation model consistently performs best across datasets or individual EEG instances, while instance-level model selection remains largely unexplored. To address this limitation, we formulate EEG foundation model selection as an instance-level Algorithm Selection (AS) problem. We propose \textbf{EEG-AS}, an instance-level algorithm selection framework that characterizes each EEG instance using inference-available latent EEG embeddings, handcrafted neurophysiological features, and an anchor foundation model. During training, EEG-AS learns to reconstruct unavailable foundation-model behaviors from privileged prediction tokens conditioned on an anchor foundation model, while during inference it estimates these behaviors without executing the entire model portfolio, enabling efficient selection from seven EEG foundation models. Experiments on seven public EEG benchmarks demonstrate that EEG-AS substantially narrows the gap between the Single Best Solver (SBS) and the oracle upper bound for each instance. These results highlight the effectiveness of instance-level AS for adaptive deployment of EEG foundation models.

0.30

Identifying Neural Source Dynamics from Unknown Local Interventions

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Jiaqi Sun, Anuar Aimoldin, Olivier Oullier, Kun Zhang
similarity 0.53
Abstract · 11 pages main text, 52 pages total including references and appendices; 3 figures

Electroencephalography (EEG) records mixtures of brain-source activity. Even with a known anatomical forward model, experiments that excite only part of the source-state space leave the dynamics unidentified, and repetition cannot resolve the ambiguity. We show that unknown local mechanism changes can supply the missing information. We consider linear dynamics among fixed anatomical sources with known source-state initialization patterns. Changing one source's update rule for one transition leaves a rank-one, source-specific signature in subsequent EEG: subtracting matched baseline responses isolates it, and the forward model identifies the source and calibrates its response history. Combining these histories with initialization responses recovers source interactions without baseline reachability and without first identifying the intervention coefficients. We establish sufficient recovery conditions, a direct estimator, and a noise-sensitivity bound conditional on correct source labels. Simulated EEG on anatomy derived from magnetic resonance imaging confirms the information gain: with baseline excitation confined to four of twelve source coordinates, eight unknown changes recover all dynamics in 32/32 systems, whereas baseline realization, baseline regression through an invertible forward model, and changes that leave the tested states unexposed all fail, and explicitly constructed alternative dynamics reproduce every baseline mean. Where baseline information suffices, direct reconstruction is also more reliable than a matched-information spectral estimator. Nonlocal changes and forward-model error limit accuracy even when source labels are correct.

0.34