CS Paper Radar

SWIMSS: An Open Multi-Center SwinUNETR Model for Multiple Sclerosis White Matter Lesion Segmentation

Federico Spagnolo, Po-Jui Lu, Mario Ocampo-Pineda, Lester Melie-Garcia, Esther Ruberte, Riccardo Galbusera, Matthias Weigel, Alessandro Cagol, Johanna Maria Lieb, Nicolin Hainc, Franca Wagner, Piotr Radojewski, Felix Tobias Kurz, Vincent Dunet, Emanuele Pravatà, Olaf Chan-Hi Kim, Patrick Roth, Marina Herwerth, Sebastian Finkener, Robert Hoepner, Patrice H. Lalive, Caroline Pot, Claudio Gobbi, Stefanie Müller, Jens Kuhle, Vincent Andrearczyk, Adrien Depeursinge, Cristina Granziera

eess.IV ·submitted 2026-11-17 13:19 UTC · v1
code/data

Abstract

Purpose: To develop and validate SWIMSS (SWInUNETR for Multiple Sclerosis white matter lesion Segmentation), a SwinUNETR-based deep learning (DL) model for reliable automated white matter (WM) lesion segmentation, in a large multicentric cohort of people with multiple sclerosis (pwMS). Methods: A real-world longitudinal dataset of 1,385 pwMS from seven Swiss clinical centers was used to train, validate, and test SWIMSS and two state-of-the-art DL architectures: UNETR and MSSegDiff. Inference results obtained with LST-AI were also compared. Preprocessed magnetization-prepared rapid acquisition gradient echo and fluid-attenuated inversion recovery MRI sequences, acquired with various MR systems and field strengths, served as model inputs. Model performance was evaluated using the Dice similarity coefficient (DSC) with 95% confidence intervals (CI). Results: SWIMSS achieved the highest performance, with a DSC of 81.37 (95% CI: 80.63-82.11), outperforming UNETR (79.06; 95% CI: 78.33-79.79), MSSegDiff (75.70; 95% CI: 74.97-76.43), and LST-AI (63.19; 95% CI: 62.08-64.30). Normalized DSC followed a similar trend, with SWIMSS reaching 84.88. Lesion detection F1 achieved 81.14. Statistical analyses confirmed its superior performance (p < 0.001). Conclusion: SWIMSS achieved state-of-the-art performance for WM lesion segmentation. By making this model publicly available, we enable broader access to high-quality segmentation tools, allowing smaller centers, often lacking large annotated datasets or computational resources, to benefit from a model trained on a diverse, large-scale cohort. This promotes more equitable access to advanced imaging analysis and supports reproducibility and standardization in MS research.

Closest papers

Nearest neighbours by meaning across the whole index.

FORESEE-MS: Toward Prospective Spatial Forecasting of Future Multiple Sclerosis Lesions from Baseline FLAIR MRI

cs.CV ·2026-10-27 ·Maryam Akhavan Aghdam, Sudip Mittal, Noorbakhsh Amiri Golilarz, Shahram Rahimi
similarity 0.73
Abstract

Traditional multiple sclerosis (MS) image analysis has primarily focused on retrospectively detecting and segmenting lesions. This study investigates whether baseline FLAIR MRI can identify regions at risk for future lesion formation beyond population-level spatial patterns. We introduce FORESEE-MS, an evaluation protocol that uses a fold-specific population-prior atlas as a baseline and assesses predictions using pooled voxel-level discrimination (AUROC and AUPRC) and within-patient lesion localization (Recall@Top-K%), with patient-level bootstrap confidence intervals. We evaluated five deep learning models (3D U-Net, Attn+ResBlock+VAE, ViT, and two SwinUNETR variants) using 5-fold cross-validation on 39 subjects from the MSSEG-2 dataset. The atlas achieved the highest pooled voxel-level AUROC and AUPRC, with no deep learning model reliably outperforming it on either metric. However, the 3D U-Net and Attn+ResBlock+VAE achieved higher mean voxel-level within-patient Recall@Top-K% than the atlas at all evaluated thresholds, although most paired confidence intervals for the differences included zero. These findings suggest that baseline FLAIR may contain patient-specific predictive information, but in this small cohort, it remains uncertain whether this information improves lesion forecasting beyond a population-prior atlas.

0.19

Longitudinal tracking of multiple sclerosis lesions in the spinal cord: A validation study

cs.CV ·2026-09-08 ·Pierre-Louis Benveniste, Julian McGinnis, Shannon Kolind, Larry D. Lynd, Sarah A. Morrow +9 more
code/dataunusual similarity 0.62
Abstract · 10 pages, 5 figures

Longitudinal characterization of multiple sclerosis (MS) lesions remains constrained by the lack of frameworks capable of establishing consistent instance-level correspondences across time. Conventional segmentation approaches produce semantic lesion masks at each visit and therefore fail to capture the complex instance temporal patterns associated with lesion appearance, disappearance, splitting, or merging. This study presents a comparative evaluation of five strategies for automated tracking of spinal cord MS lesions in longitudinal MRI data from a multi-site cohort. The investigated strategies rely either on deformable registration or on a spinal anatomical reference system, and encompass overlap-based matching, coordinate-based Hungarian algorithm, gradient-boosted classification, and Siamese model classification. Tracking accuracy is quantified using instance-level true positives, false positives, and false negatives, allowing to assess the presence of one-to-many and many-to-one associations. Results show best performance for the registration-based overlap method. This study provides the first systematic analysis of lesion-instance correspondence in the spinal cord and outlines the strengths and limitations of registration-based and registration-free paradigms for longitudinal MS assessment. The code is available at http://github.com/ivadomed/longitudinal-sc-ms-lesion-tracking .

0.46

Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

cs.CV ·2026-08-26 ·Atle Bjørnerud, Till Schellhorn, Thor H. Skattør, Terje Nome, Jon André Ottesen +2 more
similarity 0.62
Abstract · 19 pages, 8 figure and 4 tables

Objective: Diffusion-weighted MRI (DWI-MRI) is the gold standard for visualizing and quantifying acute ischaemic stroke (AIS). Although deep learning methods can accurately segment AIS lesions, the optimal image inputs and model architecture remain uncertain. We evaluated whether accurate AIS lesion segmentation can be achieved using a pragmatic deep learning approach with minimal preprocessing and clinically feasible inference times. Materials and Methods: Self-configured nnU-Net models were trained on 1,744 DWI cases from local, national, and open-access datasets and tested on 436 cases. Four experimental conditions were evaluated using five-fold cross-validation: with or without brain extraction and using either DWI alone or DWI plus apparent diffusion coefficient (ADC) images as inputs. Two architectures were compared: the baseline nnU-Net (base) and a residual encoder nnU-Net (ResEnc). Performance was benchmarked against the DeepISLES ensemble model from the 2022 ISLES challenge. Results: In the test set (n=436), the base model achieved a median (IQR) Dice similarity coefficient (DSC) of 0.84 (0.19). For the base model, only two of six pairwise comparisons between input configurations showed significant differences. ResEnc produced small but significant improvements in DSC compared with the base model for DWI, DWI+brain extraction, and DWI+ADC inputs (all p<0.02), but not for DWI+ADC+brain extraction (p>0.50). The base model significantly outperformed DeepISLES, particularly in patients with smaller infarct volumes (signed-rank test, p<0.01). Conclusions: A baseline nnU-Net trained on DWI alone, without preprocessing, enabled fast and accurate AIS lesion segmentation. This streamlined approach may facilitate clinical research and support acute stroke imaging workflows

0.22

Hetero-modal learning and corruption-resistant hetero-modal inference for joint segmentation of white matter hyperintensities and ischaemic stroke lesions in MRI

eess.IV ·2026-09-30 ·Jesse Phitidis, William N. Whiteley, Joanna M. Wardlaw, Miguel O. Bernabeu, Francesco Dalla Serra +1 more
similarity 0.60
Abstract

White matter hyperintensities (WMH) and ischaemic stroke lesions (ISL) are visually confounding, co-occurring pathologies that require large, diverse datasets for robust deep learning segmentation. However, assembling such datasets is hindered by cohort samples that lack reference segmentations from both features and complete sets of MRI structural sequences (i.e., "modalities"). To maximise data utility, we investigate hetero-modal learning using a dataset of 206 vascular disease patients across four MRI sequences (T1-weighted, T2-weighted, fluid-attenuated inversion recovery, and diffusion-weighted imaging) with expert annotations of both WMH and ISL. We demonstrate that hetero-modal learning outperforms models trained using a single imaging modality in scenarios with substantial missing data, including a split where only 10% of the training data contains all four modalities while the remainder is uni-modal, and a split relying on a single shared "anchor" modality with zero overlap between the remaining modalities. Furthermore, models trained under this second split successfully perform inference on unseen combinations of modalities. Yet, while standard hetero-modal networks handle missing sequences, clinical deployment introduces the additional challenge of silent data degradation - where modalities are present but severely corrupted. To bridge this gap, we introduce the Multimodal Attention Router (MMAR) block. Our experiments demonstrate that, when trained with a "corruption augmentation" strategy, the MMAR effectively dynamically weights the encoded features of each modality, maintaining strong performance during hetero-modal inference even in the presence of unflagged catastrophically corrupted modalities.

0.13

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published similarity 0.60
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31

Interpretable Multimodal MRI-Clinical Fusion for Functional Outcome Prediction After Acute Ischemic Stroke

cs.LG cs.AIcs.CVeess.IV ·2026-11-05 ·Sina Raeisadigh, Henning Müller, Abderrahmane Hedjoudje
similarity 0.59
Abstract · 5 pages, 2 figures, 1 table

This study evaluates the added prognostic value of day-1 multimodal MRI for predicting three-month functional outcome after acute ischemic stroke (AIS). Sixty-six AIS patients with ADC, DWI, FLAIR, and clinical data were analyzed. Three-dimensional pretrained ResNet embeddings were extracted from each MRI modality, reduced using fold-isolated principal component analysis, and combined with structured clinical variables and ADC-derived lesion biomarkers. Linear support vector machines were evaluated using eight-fold stratified group cross-validation across MRI modality combinations. Clinical-only modeling achieved strong performance (AUC = $0.899 \pm 0.151$), while MRI-only models showed limited discrimination (AUC $\approx$ $0.67$-$0.73$). Among multimodal configurations, FLAIR-clinical fusion achieved the highest mean cross-validated performance (AUC = $0.948 \pm 0.061$), followed by ADC-clinical fusion (AUC = $0.941 \pm 0.094$). Full ADC-DWI-FLAIR fusion did not consistently outperform single-modality clinical fusion. Feature-importance analysis identified age, NIHSS subscores, ADC lesion burden, and learned FLAIR representations as key contributors, while qualitative FLAIR activation maps showed responses over lesion-like regions. These findings suggest that compact day-1 FLAIR and ADC representations provide complementary prognostic information beyond clinical variables and support interpretable, data-efficient outcome prediction in AIS.

0.16

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

cs.CV ·2026-10-26 ·Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl +3 more
hot direction similarity 0.59
Abstract · 28 pages, 6 main figures, 4 main tables; supplementary material includes 6 sections, 2 figures, and 1 table

We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

0.25

dMRI-F: A Foundation Model for Generalizable Diffusion MRI Analysis from Sparse Acquisitions

cs.CV ·2026-10-13 ·Xi Zhu, Yijie Li, Xiaofan Wang, Wei Zhang, Huafu Chen +2 more
similarity 0.58
Abstract

Diffusion MRI (dMRI) probes water diffusion within the brain, providing unique information about tissue microstructure and white matter connectivity. High-quality dMRI enables advanced and accurate analyses but demands dense acquisitions, resulting in long scan times and hardware constraints that are often infeasible. Further, dMRI requires dedicated computational methods to support diverse analysis tasks (e.g., parcellation, registration, and synthesis) for both neuroscientific and clinical applications. Here, we present dMRI-F, a foundation model that unifies dMRI data enhancement and downstream tasks across diverse acquisitions and populations, while requiring only minimal acquisition input. dMRI-F is pre-trained with a q-space masked reconstruction task: predicting densely sampled multi-shell data from only six volumes. It learns generalizable latent feature representations of dMRI data, which serve as a core foundation for adapting to diverse downstream tasks, including brain parcellation, brain registration, and cross-modal synthesis. Across nine independently acquired datasets, we demonstrate that dMRI-F outperforms state-of-the-art methods with robust generalization across acquisitions, populations, and tasks. Our results demonstrate dMRI-F's versatility as a general-purpose framework that enables diverse dMRI applications from low-cost, sparse acquisitions.

0.15